Key Findings The ETENWOLF C2PV tire inflator successfully passed a 1-hour random vibration test conducted under ISTA-2A protocols, with all 3 samples showing no functional failures, no abnormal startup behavior, and normal charging performance after the test. Product: C2PV Tire Inflator (C2PV-充气泵) Standard: ISTA-2A Report…

Document type
Test Report
Prepared by
Daniel Wright
Published
Last reviewed
Topics
Others

Key Findings

The ETENWOLF C2PV tire inflator successfully passed a 1-hour random vibration test conducted under ISTA-2A protocols, with all 3 samples showing no functional failures, no abnormal startup behavior, and normal charging performance after the test.

  • Product: C2PV Tire Inflator (C2PV-充气泵)
  • Standard: ISTA-2A
  • Report No.: 2025110101
  • Test Date: 2025-11-01
  • Sample Quantity: 3 PCS
  • Test Duration: 1 hour
  • Vibration Mode: Random, axes X / Y / Z
  • Frequency: 4 Hz
  • Amplitude: 25.4 mm
  • Speed (CMP): 240 G
  • Verdict: PASS

Test Overview

Field Details
Test Type Vibration Test (Vibration Test Report)
Standard / Test Class ISTA-2A
Report No. 2025110101
Page 1
Date 2025-11-01
Product Name C2PV Tire Inflator (C2PV-充气泵)
Manufacturer BTK
Surface Treatment /
Sample Quantity 3 PCS
Test Reason New Product
Test Objective To verify the resistance of the sample in transportation and use environment.
Laboratory Environment Temperature: 22 °C; Humidity: 55% RH

Test Equipment & Setup

Parameter Value
Instrument Name Vibration Testing Machine
Test Mode Random Mode
Test Duration 1 Hour
Vibration Axes Random Direction: X, Y, Z
Vibration Frequency 4 Hz
Test Speed (CMP) 240 G
Vibration Amplitude 25.4 mm

Test Procedure

  1. Pre-Test: Inspect all 3 samples for visible damage. Power on each unit and verify normal startup and charging function. Document baseline condition with photographs of vibration placement and vibration control chart.
  2. Setup: Place packaged samples on the vibration testing machine platform. Configure the machine to Random Mode with X, Y, Z axis random direction, frequency of 4 Hz, amplitude of 25.4 mm, and speed of 240 G.
  3. Test Execution: Run the vibration test continuously for 1 hour, simulating the real transportation environment to ensure packaging effectively protects the product.
  4. Post-Test Inspection: Power on each sample and verify startup is normal. Test charging function on all samples. Inspect packaging and product for any physical damage or functional failure.
  5. Acceptance Criteria: Packaging must effectively protect the product throughout the simulated transport vibration. All samples must power on without anomaly, charge normally, and exhibit no functional failures. Judgment: Pass / Fail / Reference.

Test Data & Results

Check Item Pre-Test Observation Post-Test Observation Result
Vibration Placement Samples positioned correctly on vibration table; vibration control chart confirmed
Power-On / Startup No anomaly before test No anomaly after test (开机无异常) Pass
Charging Function Normal before test Normal after test (充电正常) Pass
Overall Functional Performance All 3 samples functional All 3 samples passed 1-hour transport vibration test; performance good, no functional failure (性能良好,功能无失效) Pass

Test Result Summary: All samples passed the 1-hour transport vibration test. Performance was good and no functional failures were observed across all 3 units. Images captured include vibration placement setup and the vibration control chart, along with post-test power-on and charging verification.

Conclusion

Item Detail
Overall Result PASS (合格)
Standard Applied ISTA-2A
Test Conditions Random vibration, X/Y/Z axes, 4 Hz, 25.4 mm amplitude, 240 G, 1 hour; Lab: 22 °C / 55% RH
Samples Tested 3 PCS C2PV Tire Inflator
Judgment ■ Pass    □ Fail    □ Reference
Verdict The C2PV tire inflator withstood the simulated transport vibration environment without any functional degradation. Packaging provided effective protection throughout the test.

Document Information

Role Name (Pinyin) Chinese Name
Approval (核准) Mai Shaoqiang 麦少强
Review / Check (审查) Zhang Ronggui 张荣贵
Tester (试验人) Li Guanghua 李光华
Field Value
Form Number BTK-R-Q-087A/1

Frequently Asked Questions

What standard was used for the ETENWOLF C2PV vibration test?

The test followed the ISTA-2A standard, which simulates the mechanical hazards a packaged product encounters during real-world transportation, including random vibration across multiple axes.

What were the key vibration test parameters for the C2PV inflator?

The test ran in Random Mode for 1 hour across X, Y, and Z axes. The vibration frequency was 4 Hz, the amplitude was 25.4 mm, and the test speed was 240 G (CMP). The laboratory environment was maintained at 22 °C and 55% RH.

Did the ETENWOLF C2PV tire inflator pass the transport vibration test?

Yes. All 3 sample units passed the 1-hour ISTA-2A random vibration test. Post-test inspection confirmed normal power-on behavior, normal charging function, and no functional failures on any unit.

How many samples were tested in the C2PV vibration test?

Three (3) production samples of the C2PV tire inflator were tested. All three passed with no anomalies detected after the full 1-hour vibration cycle.

Related Products

Explore other ETENWOLF inflation tools and their reliability test reports: