This page presents the official REACH SVHC test report for the ETENWOLF C2PRO Wireless Portable Tire Pump, issued by Waltek Testing Group (Shenzhen) Co., Ltd. The report was prepared in accordance with European Commission Regulation (EC) No 1907/2006 (REACH) to assess the presence of Substances of Very High Concern (SVHC) in the product.

Field Details
Report Number WTH25X11289151C
Document Type REACH SVHC Screening Test Report
Issuing Laboratory Waltek Testing Group (Shenzhen) Co., Ltd.
Date of Issue 2025-11-24
Regulation EC No 1907/2006 (REACH), SVHC Candidate List
Scope 251 Substances of Very High Concern (SVHC) and 4 potential substances listed on ECHA Candidate List
Test Conclusion All tested SVHC concentrations are less than 0.1% (w/w) — PASS

Product Information

The tested product is the C2PRO, a Wireless Portable Tire Pump manufactured and supplied by Guangdong Bestek Technology Co., Ltd. under the ETENWOLF brand. The device is designed for inflating vehicle tires and other inflatables without requiring a wired power connection.

Field Details
Sample Name Wireless Portable Tire Pump
Model Number C2PRO
Reference Model N/A
Brand ETENWOLF
Applicant Guangdong Bestek Technology Co., Ltd.
Applicant Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China
Manufacturer Guangdong Bestek Technology Co., Ltd.
Manufacturer Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China

Key Details

The laboratory conducted SVHC screening across multiple sample groups (T01 through T04) drawn from different components or material fractions of the C2PRO. All groups returned a result of Not Detected (ND) for each of the 251 listed SVHC substances and 4 additional potential substances identified on the ECHA Candidate List.

Group No. Substances Screened CAS No. Result (%, w/w) Reporting Limit (%, w/w)
T01 251 SVHC + 4 potential substances (Candidate List) Multiple ND <0.1%
T02 251 SVHC + 4 potential substances (Candidate List) Multiple ND <0.1%
T03 251 SVHC + 4 potential substances (Candidate List) Multiple ND <0.1%
T04 251 SVHC + 4 potential substances (Candidate List) Multiple ND <0.1%

The threshold limit under REACH Article 59 is 0.1% (w/w) per substance in any article. All results fell below this threshold, confirming full compliance.

Testing Timeline:

  • Sample Receipt: 2025-11-04 and 2025-11-17
  • Testing Period: 2025-11-04 to 2025-11-11 and 2025-11-17 to 2025-11-18
  • Report Issued: 2025-11-24

Standards & Compliance

The SVHC screening for the C2PRO was conducted using an in-house analytical method referencing the following internationally recognised standards and protocols:

Standard / Method Scope
EPA 3550C:2007 Ultrasonic extraction for semi-volatile organic compounds
US EPA 8270D:2018 GC/MS determination of semi-volatile organic compounds
US EPA 3052:1996 Microwave-assisted acid digestion of siliceous and organically based matrices
US EPA 3050B:1996 Acid digestion of sediments, sludges, and soils
US EPA 6010D:2018 Inductively coupled plasma – optical emission spectrometry (ICP-OES)
BS EN ISO 14362-1:2017 Azo colorants – determination of aromatic amines from azo colorants (Part 1)
BS EN ISO 14362-3:2017 Azo colorants – determination of 4-aminoazobenzene (Part 3)
ISO 17234-1:2020 Chemical tests for leather – determination of restricted azo colorants (Part 1)
ISO 17234-2:2011 Chemical tests for leather – determination of 4-aminoazobenzene (Part 2)
ISO 17353:2004 Water quality – determination of selected organotin compounds
AfPS GS 2019:01 PAK Polycyclic aromatic hydrocarbons (PAH) in consumer goods

The overarching regulatory framework is REACH Regulation (EC) No 1907/2006, specifically addressing obligations under Article 59 regarding the SVHC Candidate List maintained by the European Chemicals Agency (ECHA).

Validity & Certification Body

The test report was issued by Waltek Testing Group (Shenzhen) Co., Ltd., an accredited third-party testing laboratory based in Shenzhen, China. The report is valid as issued and covers the specific sample batch received and tested during the stated testing period.

Field Details
Report Number WTH25X11289151C
Date of Issue 2025-11-24
Issuing Laboratory Waltek Testing Group (Shenzhen) Co., Ltd.
Laboratory Address 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70, Bao’an District, Shenzhen, Guangdong, China
Laboratory Website http://www.waltek.com.cn
Contact Tel +86-755-33663308
Contact Fax +86-755-33663309
Contact Email [email protected]
Signed By Hugo Chen, Waltek Testing Group (Shenzhen) Co., Ltd.
Validity Note Valid for the tested sample batch; renewal recommended upon significant design or material change

Frequently Asked Questions

What does REACH SVHC compliance mean for the C2PRO tire pump?

REACH SVHC compliance means that the C2PRO has been independently tested and confirmed to contain none of the 251 Substances of Very High Concern — including carcinogens, mutagens, reproductive toxins, and persistent bio-accumulative substances — at or above the 0.1% (w/w) threshold set by EU REACH Regulation (EC) No 1907/2006. This allows the product to be legally sold throughout the European Economic Area.

Which laboratory conducted this REACH test and is it accredited?

The test was performed by Waltek Testing Group (Shenzhen) Co., Ltd. (Report No. WTH25X11289151C), a third-party testing laboratory located in Shenzhen, China. Waltek is a recognised testing and certification organisation serving global markets. You can verify their services at www.waltek.com.cn.

How many substances were screened in this report?

The test screened for 251 Substances of Very High Concern (SVHC) plus 4 additional potential substances, as listed on the ECHA Candidate List at the time of testing. All results were Not Detected (ND) across all sample groups, well below the 0.1% (w/w) reporting limit.

Does this report need to be renewed if the product design changes?

Yes. REACH SVHC testing is tied to a specific sample batch and its material composition. If the C2PRO undergoes significant changes to its materials, components, or supplier chain, a new SVHC screening test should be conducted to maintain valid compliance documentation. Additionally, as ECHA periodically updates the Candidate List, periodic re-testing is recommended to cover newly added substances.

Related Documents

The REACH SVHC report is one part of the broader compliance documentation for the C2PRO Wireless Portable Tire Pump. The following related certification and compliance documents are recommended for a complete regulatory profile:

  • RoHS Compliance Report — Restriction of Hazardous Substances in electrical and electronic equipment under EU Directive 2011/65/EU, covering lead, mercury, cadmium, hexavalent chromium, PBB, PBDE, and four additional phthalates.
  • CE Declaration of Conformity — Confirms the C2PRO meets EU safety, health, and environmental requirements for market access across the European Economic Area.
  • FCC ID Certification — Required for wireless device compliance in the United States, covering radio frequency emissions under FCC Part 15.
  • UN 38.3 Battery Transport Test Report — Mandatory for the lithium-ion battery contained within the C2PRO, ensuring safe transport compliance under UN Manual of Tests and Criteria, Part III, Section 38.3.
  • KC Certification — Required for product sales in the Republic of Korea, covering electromagnetic compatibility and safety under KC Mark regulations.
  • IEC 62133 Battery Safety Test Report — Covers secondary lithium cells and batteries used in portable applications under the IEC standard.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22
Document Page 23
Document Page 24
Document Page 25
Document Page 26
Document Page 27
Document Page 28
Document Page 29
Document Page 30