Document Overview
Key Findings The ETENWOLF EV3 tire inflator (model V3C1) was tested for operational noise level with a sound level meter positioned 1 m from the front face of the unit; all three samples measured between 83.1 dB and 85.1 dB, and the report is issued…
- Document type
- Test Report
- Prepared by
- Daniel Wright
- Published
- Last reviewed
- Topics
- Noise Testing
Key Findings
The ETENWOLF EV3 tire inflator (model V3C1) was tested for operational noise level with a sound level meter positioned 1 m from the front face of the unit; all three samples measured between 83.1 dB and 85.1 dB, and the report is issued for reference only with no pass/fail threshold applied.
- Product: EV3 Tire Inflator, model V3C1
- Report No.: 2025040701
- Test Date: 2025-04-07
- Samples: 3 PCS
- Measurement distance: 1 m (microphone to front face, horizontal)
- Noise range: 83.1 dB – 85.1 dB
- Verdict: For Reference Only (no numeric limit defined)
Test Overview
| Field | Detail |
|---|---|
| Test Type | Noise Testing (Reliability Test) |
| Test Standard | Internal Standard |
| Numeric Limit Standard | / (none specified) |
| Report No. | 2025040701 |
| Test Date | 2025-04-07 |
| Product No. / Name | EV3 Tire Inflator (充气泵) |
| Model / Type Specification | V3C1 |
| Manufacturer | ETENWOLF |
| Sample Quantity / No. | 3 PCS |
| Test Purpose | Evaluate the noise level of the EV3 tire inflator during operation. |
Test Equipment & Setup
| Item | Detail |
|---|---|
| Test Equipment | Sound Level Meter (噪音计) |
| Ambient Temperature | 23 °C |
| Ambient Humidity | 60 %RH |
| Microphone Distance | 1 m from front face of product (horizontal) |
| Product State During Test | Powered on (normal operating state) |
Test Procedure
- Pre-test: Confirm ambient conditions — temperature 23 °C, relative humidity 60 %. Verify sound level meter calibration.
- Sample preparation: Place each sample (1#, 2#, 3#) on a stable surface. Position the microphone at a horizontal distance of 1 m from the front face of the unit.
- Test execution: Power on the inflator. Record the noise reading in dB from the sound level meter while the unit is running.
- Post-test: Power off the unit. Record the measured noise value for each sample.
- Acceptance criteria: No numeric pass/fail threshold is defined for this test. Results are issued for reference only.
Test Data & Results
| Sample No. (编号) | Direction (方向) | Microphone Distance (距离麦克风距离) | Noise Level — dB (噪音) |
|---|---|---|---|
| 1# | Front Face (正面) | 1 M | 85.1 |
| 2# | Front Face (正面) | 1 M | 83.8 |
| 3# | Front Face (正面) | 1 M | 83.1 |
Observations: All three samples produced consistent readings within a 2 dB spread. The highest recorded value was 85.1 dB (Sample 1#) and the lowest was 83.1 dB (Sample 3#). No anomalous noise events were noted during the test. Because no formal numeric limit is defined in the applicable standard field, the report carries a "For Reference Only" designation rather than a pass or fail verdict.
Conclusion
| Item | Detail |
|---|---|
| Parameter Tested | Operational Noise Level |
| Standard Applied | Internal Standard (no numeric limit) |
| Test Conditions | 23 °C / 60 %RH, microphone at 1 m horizontal from front face |
| Samples Tested | 3 PCS (1#, 2#, 3#) |
| Results | 85.1 dB / 83.8 dB / 83.1 dB |
| Verdict | For Reference Only (■供参考) |
Document Information
| Role | Name (Pinyin) | Date |
|---|---|---|
| Tested By (测试/日期) | Li Guanghua | 2025-04-07 |
| Checked By (审核/日期) | Zhang Ronggui | 2025-04-07 |
| Approved By (核准/日期) | Mai Shaoqiang | 2025-04-07 |
| Form / Report No. | 2025040701 | — |
Frequently Asked Questions
How loud is the ETENWOLF EV3 tire inflator during operation?
When tested at 1 m horizontal distance from the front face, the EV3 produced noise levels of 85.1 dB, 83.8 dB, and 83.1 dB across three samples — an average of approximately 84 dB under standard indoor conditions (23 °C / 60 %RH).
What test standard was used for the EV3 noise measurement?
The test followed ETENWOLF’s internal reliability test standard. No third-party numeric pass/fail threshold (such as an IEC or ISO limit) was applied, so the results are designated for reference only rather than as a formal compliance verdict.
At what distance is the noise of the EV3 inflator measured?
The sound level meter microphone was positioned at a horizontal distance of 1 m from the front face of the inflator while the unit was powered on and running, which is the measurement geometry specified in the internal test procedure.
Does the EV3 pass the noise test?
Because no numeric noise limit is defined in the current test standard for this product, a pass or fail verdict is not assigned. The three samples measured 83.1–85.1 dB and the report is issued as reference data for product development and quality tracking purposes.
Related Products
Explore other ETENWOLF inflation tools and their test documentation:
- ETENWOLF Official Website
- ETENWOLF Inflation Tools Product Line