Document Overview
Key Findings All 6 HB1 air pump samples successfully passed the simulated transport vibration test under ISTA-2A protocol, with no functional failure, stable working performance, and good durability. Product: HB1 Air Pump (HB1-吹气泵) Standard: ISTA-2A Report No.: 2025072301 Test Date: 2025-07-23 Samples: 6 PCS Test…
- Document type
- Test Report
- Prepared by
- Alex Newman
- Published
- Last reviewed
- Topics
- Mechanical Reliability
Key Findings
All 6 HB1 air pump samples successfully passed the simulated transport vibration test under ISTA-2A protocol, with no functional failure, stable working performance, and good durability.
- Product: HB1 Air Pump (HB1-吹气泵)
- Standard: ISTA-2A
- Report No.: 2025072301
- Test Date: 2025-07-23
- Samples: 6 PCS
- Test Mode: Random vibration, axes X / Y / Z
- Duration: 1 hour
- Frequency: 4 Hz
- Amplitude: 25.4 mm
- Speed (CMP): 240 G
- Verdict: PASS
Test Overview
| Field | Details |
|---|---|
| Test Type | Vibration Test (Transport Simulation) |
| Test Standard | ISTA-2A |
| Report No. | 2025072301 |
| Page | 1 |
| Date | 2025-07-23 |
| Product Name | HB1 Air Pump (HB1-吹气泵) |
| Manufacturer | BTK |
| Surface Treatment | / |
| Sample Quantity | 6 PCS |
| Test Reason | New Product |
| Test Objective | To verify the resistance of the sample under transportation and use environment vibration conditions. |
| Laboratory Environment | Temperature: 30 °C; Humidity: 55% RH |
Test Equipment & Setup
| Item | Parameter | Value |
|---|---|---|
| Instrument | Name | Vibration Testing Machine |
| Test Mode | Pattern | Random Mode |
| Test Duration | Time | 1 H |
| Vibration Axes | Direction | X, Y, Z (Random) |
| Vibration Frequency | Frequency | 4 Hz |
| Test Speed | CMP | 240 G |
| Vibration Amplitude | Amplitude | 25.4 mm |
| Test Class / Standard | Level | ISTA-2A |
Test Procedure
- Pre-Test Inspection: Power on each of the 6 HB1 samples and confirm normal startup operation. Verify charging function is normal. Record initial condition of all samples.
- Sample Placement: Mount samples on the vibration table in the designated orientation as shown in the vibration placement diagram (振动摆放).
- Parameter Configuration: Set the vibration testing machine to Random Mode, frequency 4 Hz, amplitude 25.4 mm, speed 240 G, axes X / Y / Z.
- Vibration Test Execution: Run the test for 1 hour continuously. Monitor the vibration control chart (振动控制图) throughout the test duration.
- Post-Test Inspection: Power on all samples after vibration. Verify power-on operation is normal. Verify charging function remains normal. Perform visual inspection for any physical damage or loose components.
- Acceptance Criteria: All samples must power on and operate normally with no functional failure, stable working performance, and acceptable durability after completion of the full 1-hour vibration cycle.
Test Data & Results
| Check Item | Pre-Test Status | Post-Test Status | Result |
|---|---|---|---|
| Power-On Operation | Normal | Normal | Pass |
| Charging Function | Normal | Normal | Pass |
| Vibration Placement Setup | Confirmed | — | Pass |
| Vibration Control Chart | — | Monitored & Stable | Pass |
| Physical / Structural Integrity | No defects | No defects | Pass |
Overall test result: All 6 samples passed the simulated transport vibration test. No functional failures were observed. Working performance remained stable throughout and after the test. Durability assessed as good.
Judgment: ■ Pass □ Fail □ Reference
Conclusion
| Field | Details |
|---|---|
| Test Result | All samples passed the simulated transport vibration test with no functional failure. |
| Standard Applied | ISTA-2A |
| Test Conditions | Random mode; 4 Hz; 25.4 mm amplitude; 240 G CMP; X/Y/Z axes; 1 hour; 30 °C / 55% RH |
| Samples Tested | 6 PCS — HB1 Air Pump |
| Working Performance | Stable |
| Durability Assessment | Good |
| Verdict | PASS |
Document Information
| Role | Name (Pinyin) |
|---|---|
| Approval (核准) | Mai Shaoqiang |
| Review (审查) | Zhang Ronggui |
| Tester (试验人) | Li Guanghua |
| Form Number | BTK-R-Q-087A/1 |
Frequently Asked Questions
What standard was used for the HB1 air pump vibration test?
The HB1 air pump vibration test was conducted in accordance with ISTA-2A, a widely recognized international standard for simulating transport vibration environments for packaged products.
What were the vibration test parameters for the HB1 air pump?
The test used random mode vibration across X, Y, and Z axes for 1 hour. Key parameters were: frequency 4 Hz, vibration amplitude 25.4 mm, and test speed 240 G CMP, conducted at 30 °C and 55% RH.
Did the ETENWOLF HB1 air pump pass the transport vibration test?
Yes. All 6 HB1 air pump samples passed the ISTA-2A transport vibration test with no functional failure. Power-on operation and charging function remained normal after the full 1-hour vibration cycle, and durability was assessed as good.
How many samples were tested in the HB1 vibration test?
Six (6) HB1 air pump units were tested simultaneously. All 6 samples passed with stable performance and no defects observed before or after the vibration test.