ETENWOLF X6PRO Tire Inflator Noise Test Report (Front-Face, 1 m Distance)

Document Overview

Key Findings All three X6PRO inflator samples measured between 76.5 dB and 79.0 dB at 1 m from the front face during powered operation, falling within the evaluated sound pressure level range of 35–100 dB — results are provided for reference. Product: X6PRO Tire Inflator…

Document type
Test Report
Prepared by
Daniel Wright
Published
Last reviewed
Topics
Noise Testing

Key Findings

All three X6PRO inflator samples measured between 76.5 dB and 79.0 dB at 1 m from the front face during powered operation, falling within the evaluated sound pressure level range of 35–100 dB — results are provided for reference.

  • Product: X6PRO Tire Inflator (充气泵)
  • Report No.: 20260207-001
  • Test Date: 2026-02-07
  • Samples: 3 PCS (units 4#, 5#, 6#)
  • Measurement standard: Internal standard — sound pressure level Lmax 35–100 dB
  • Highest reading: 79.0 dB (sample 5#)
  • Lowest reading: 76.5 dB (sample 6#)
  • Verdict: For reference only

Test Overview

Field Details
Test Type Noise Testing — Reliability Test (可靠性测试)
Test Standard Internal Standard — Sound Pressure Level Lmax 35–100 dB
Report No. 20260207-001
Test Date 2026-02-07
Product No. / Name 充气泵 (Tire Inflator)
Model / Specification X6PRO
Manufacturer / Brand ETENWOLF
Sample Quantity / No. 3 PCS
Test Purpose Evaluate the noise level of the sample under different operating scenarios
Environment Room temperature 23 °C, relative humidity 60%

Test Equipment & Setup

Item Details
Test Equipment Sound Level Meter (噪音计)
Microphone Distance 1 m horizontal from front face of product
Product State Powered on (operating)
Measurement Range Lmax 35–100 dB
Temperature 23 °C
Relative Humidity 60%

Test Procedure

  1. Pre-test: Confirm the test environment is at room temperature (23 °C) and 60% relative humidity. Inspect the three sample units (4#, 5#, 6#) for any visible defects before testing.
  2. Equipment setup: Position the sound level meter microphone at a horizontal distance of 1 m from the front face of the product, at the same height as the product.
  3. Power on: Switch the X6PRO inflator to its operating (powered-on) state.
  4. Measurement: Record the maximum sound pressure level (dB) displayed on the sound level meter for each sample in the front-face direction at 1 m distance.
  5. Repeat: Perform the measurement for each of the three samples (4#, 5#, 6#) under identical conditions.
  6. Post-test: Power off the device. Document all readings and compare against the acceptance criterion of Lmax 35–100 dB.

Acceptance Criterion: Sound pressure level must fall within Lmax 35–100 dB. Results in this report are provided for reference only.

Test Data & Results

Sample No. (编号) Direction (方向) Microphone Distance (距离麦克风距离) Noise Level / dB (噪音)
4# Front (正面) 1 m 76.7
5# Front (正面) 1 m 79.0
6# Front (正面) 1 m 76.5

Observations: All three readings fall within the evaluated range of 35–100 dB. Sample 5# returned the highest value at 79.0 dB; sample 6# the lowest at 76.5 dB. The spread across samples is 2.5 dB, indicating consistent acoustic performance across the batch. No anomalies were recorded during testing.

Conclusion

Field Details
Result Range 76.5 dB – 79.0 dB
Evaluation Standard Internal standard — Lmax 35–100 dB
Test Conditions Front face, 1 m distance, 23 °C, 60% RH, product powered on
Samples Tested 3 PCS (4#, 5#, 6#)
Verdict For Reference Only (■供参考)

Document Information

Role Name (Pinyin) Date
Tested By (测试/日期) Li Guanghua 2026-02-07
Checked By (审核/日期) Zhang Ronggui 2026-02-07
Approved By (核准/日期) Mai Shaoqiang 2026-02-07
Report No. 20260207-001
Source File X6pro充气泵-噪音测试_2026.2.7.xlsx

Frequently Asked Questions

How loud is the ETENWOLF X6PRO tire inflator during operation?

In controlled testing at 1 m from the front face, the X6PRO measured between 76.5 dB and 79.0 dB across three samples. This is comparable to a typical household vacuum cleaner and is normal for a portable tire inflator operating at full load.

What test standard was used to evaluate the X6PRO noise level?

The test was conducted against ETENWOLF’s internal standard, which evaluates sound pressure level (Lmax) within the range of 35–100 dB. All three samples fell well within this range.

At what distance was the noise measurement taken for the X6PRO?

The sound level meter microphone was positioned at a horizontal distance of 1 m from the front face of the X6PRO inflator, with the product in its powered-on operating state.

Did the X6PRO pass the noise test?

The test results are classified as “For Reference Only” rather than a pass/fail assessment. All readings (76.5–79.0 dB) fall within the evaluated Lmax range of 35–100 dB, confirming the product operates within expected acoustic parameters.