Document Overview
Document Overview This test report documents the safety certification testing of the V3 air pump conducted by Shenzhen Waltek Testing Technology Co., Ltd. The report number is WTH25X04079174G, issued on April 8, 2025. The testing was performed according to GB4706.1-2005 standard (Household and Similar Electrical…
- Document type
- Certification Report
- Prepared by
- Michelle Torres
- Published
- Last reviewed
- Topics
- Compliance & Certification
Document Overview
This test report documents the safety certification testing of the V3 air pump conducted by Shenzhen Waltek Testing Technology Co., Ltd. The report number is WTH25X04079174G, issued on April 8, 2025.
The testing was performed according to GB4706.1-2005 standard (Household and Similar Electrical Appliances – Part 1: General Requirements). Testing period: April 1-7, 2025. Sample reception date: April 1, 2025.
The test was commissioned by and manufactured by Guangdong Beishidake Technology Co., Ltd., located at No. 1 North Gaopuo 8th Road, Industrial Park, Yuancheng District, Heyuan City.
Product Information
The tested product is a portable air pump with the following specifications:
- Product Name: Air Pump (充气泵)
- Model: V3
- Input Interface: TYPE-C
- Rated Voltage: 5V DC
- Rated Current: 3A
- Power Source: Direct Current (DC)
- Protection Class: Class III (Safety Extra-Low Voltage)
- Protection Level: IPX0 (no water protection marking required)
- Device Type: Portable
- Control Method: Electronic circuit
- Trademark: Not specified
- Sample Quantity: 1 unit
- Sample Condition: Complete and intact
The product connects to power via TYPE-C input at 5V 3A. It is classified as a Class III appliance, meaning it operates at safety extra-low voltage for enhanced user protection.
Key Details
| Test Item | Standard Clause | Result |
|---|---|---|
| Marking and Instructions | Clause 7 | Pass |
| Input Power and Current | Clause 10 | Pass |
| Leakage Current and Electrical Strength at Operating Temperature | Clause 13 | Pass |
| Leakage Current and Electrical Strength | Clause 16 | Pass |
| Stability and Mechanical Hazards | Clause 20 | Pass |
| Mechanical Strength | Clause 21 | Pass |
| Structure | Clause 22 | Pass |
Test Environment: Ambient temperature: 20±5°C, Relative humidity: 60±10% R.H.
Overall Conclusion: All tested items meet the standard requirements.
Standards & Compliance
The V3 air pump was tested according to GB4706.1-2005 standard titled ‘Safety of Household and Similar Electrical Appliances – Part 1: General Requirements’.
This Chinese national standard is equivalent to the international IEC 60335-1 standard and covers comprehensive safety requirements for household electrical appliances including:
- Marking Requirements: Verification that all necessary markings (voltage, current, manufacturer information, model number) are present, clear, durable, and correctly positioned
- Electrical Safety: Testing of leakage current levels and dielectric strength to ensure user protection from electric shock
- Power Performance: Verification that actual input power and current are within acceptable tolerances of rated values
- Mechanical Safety: Assessment of structural integrity, stability, and resistance to mechanical stress
- Temperature Performance: Evaluation of the device’s electrical safety characteristics under normal operating temperature conditions
The testing methodology follows IEC 60990 for leakage current measurement and references GB4208 (equivalent to IEC 60529) for IP protection classification verification.
Label durability was tested by wiping with water and gasoline for 15 seconds each, confirming the markings remain clear and legible without curling or easy removal.
Validity & Certification Body
Testing Laboratory: Shenzhen Waltek Testing Technology Co., Ltd.
Laboratory Address: 1st Floor, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Area 70, Bao’an District, Shenzhen, Guangdong Province, China
Contact Information:
- Phone: +86-755-33663308
- Fax: +86-755-33663309
- Email: [email protected]
- Website: http://www.waltek.com.cn
Report Personnel:
- Chief Inspector: Ye Jintao
- Reviewer: Gao Guanquan
- Approver: Wei Wenyong
Report Template Number: WTX_GB4706_1_2005A
Test Classification: Commissioned Testing
This report certifies that the tested sample met all requirements at the time of testing. The validity period and applicability should be confirmed with the manufacturer or certification body for specific market requirements.
Frequently Asked Questions
What does GB4706.1-2005 certification mean for the V3 air pump?
GB4706.1-2005 certification means the V3 air pump has been tested and verified to meet China’s national safety standards for household electrical appliances. This ensures the product has proper electrical insulation, safe current levels, adequate mechanical strength, and correct safety markings to protect users from electrical hazards during normal operation.
What is Class III protection and why is it important?
Class III protection means the V3 air pump operates at Safety Extra-Low Voltage (SELV), specifically 5V DC in this case. This voltage level is inherently safe and poses minimal risk of electric shock to users. Class III devices do not require grounding and provide the highest level of electrical safety, making them ideal for portable consumer products.
What does IPX0 protection level indicate?
IPX0 means the V3 air pump has no specific rating for water ingress protection. This classification indicates the device is designed for dry environments and should not be exposed to water or moisture. Users should keep the device away from rain, splashes, and humid conditions to ensure safe operation.
Can I use any USB-C charger with the V3 air pump?
The V3 air pump is rated for 5V 3A input via TYPE-C connection. You should use a charger that can supply at least 3A at 5V (15W) to ensure proper operation. Using an underpowered charger may result in reduced performance or charging issues. Always verify your charger’s output specifications match or exceed the device requirements.
Related Documents
For the V3 air pump, the following related certification documents may be relevant depending on target markets and regulatory requirements:
- EMC Testing Report: Electromagnetic compatibility certification to verify the device does not cause or is not affected by electromagnetic interference
- Battery Safety Certification: If the device contains rechargeable batteries, testing according to UN38.3 or GB 31241 standards for lithium battery safety
- RoHS Compliance Report: Verification that the product complies with RoHS restrictions on hazardous substances in electrical equipment
- REACH Compliance: Declaration of conformity with EU REACH regulation for chemical substances
- CE Marking Documentation: For European market access, including Low Voltage Directive (LVD) and EMC Directive compliance
- FCC Certification: For United States market, FCC Part 15 compliance for electronic devices
- CCC Certification: China Compulsory Certification if required for the product category and market distribution
- Performance Testing Report: Verification of inflation performance, pressure accuracy, and operational specifications
Document Pages