Document Overview
Key Findings All 3 samples of the HB1 Air Pump passed the operating temperature test across four thermal conditions with no functional failures and stable performance throughout. Product: HB1 Air Pump (吹气泵) Report No.: 2025072201 Test Date: 2025-07-22 Samples: 3 PCS (Sample IDs 4#–6#) Standard:…
- Document type
- Test Report
- Prepared by
- Alex Newman
- Published
- Last reviewed
- Topics
- Environmental Testing
Key Findings
All 3 samples of the HB1 Air Pump passed the operating temperature test across four thermal conditions with no functional failures and stable performance throughout.
- Product: HB1 Air Pump (吹气泵)
- Report No.: 2025072201
- Test Date: 2025-07-22
- Samples: 3 PCS (Sample IDs 4#–6#)
- Standard: Internal Control Standard
- Test Type: Reliability Test
- Verdict: PASS — all samples functioned normally under all four temperature conditions
Test Overview
| Field | Details |
|---|---|
| Test Type | Operating Temperature Test (Reliability Test) |
| Test Standard | Internal Control Standard |
| Report No. | 2025072201 |
| Test Date | 2025-07-22 |
| Product No. / Name | HB1 Air Pump (吹气泵) |
| Model / Specification | HB1 |
| Manufacturer / Product Line | ETENWOLF — Inflation Tools |
| Sample Quantity / ID | 3 PCS (4#, 5#, 6#) |
| Test Environment | Room Temperature: 23 °C, Relative Humidity: 60% |
| Test Purpose | Evaluate the effect of high and low temperature storage conditions on the operational temperature performance of the samples |
Test Equipment & Setup
| Item | Details |
|---|---|
| Test Equipment | Constant Temperature & Humidity Chamber / Oven / Power Meter |
| Room Temperature | 23 °C |
| Room Humidity | 60% RH |
| Low-Temperature Charge Condition | 0 °C, storage duration: 2 hours |
| Mid-Temperature Charge Condition | 45 °C, storage duration: 2 hours |
| High-Temperature Discharge Condition | 74 °C, storage duration: 2 hours |
| Low-Temperature Discharge Condition | -20 °C, storage duration: 2 hours |
Test Procedure
- Pre-Test: Record ambient conditions (temperature 23 °C, humidity 60%). Assign sample IDs 4#, 5#, 6#. Confirm all samples are in normal initial working condition.
- Low-Temperature Charge Test: Place samples in the constant temperature chamber set to 0 °C. Allow samples to stabilize for 2 hours. Apply charging conditions and observe charging display behavior.
- Mid-Temperature Charge Test: Set chamber to 45 °C. Allow samples to stabilize for 2 hours. Apply charging conditions and observe charging display behavior.
- High-Temperature Discharge Test: Set chamber/oven to 74 °C. Allow samples to stabilize for 2 hours. Power on samples and evaluate operational performance and stability.
- Low-Temperature Discharge Test: Set chamber to -20 °C. Allow samples to stabilize for 2 hours. Power on samples and evaluate operational performance and stability.
- Post-Test: Return samples to room temperature. Document all observations, record any anomalies, and compare against acceptance criteria.
Acceptance Criteria: Samples must operate normally within the specified environmental temperature range. Charging display must function correctly under charge conditions. Samples must power on and perform normally under discharge conditions.
Test Data & Results
| Sample ID | Test Condition | Observations / Issue Description |
|---|---|---|
| 4#–6# | Low-Temperature Charge Test | After 2 hours storage at 0 °C, charging display functioned normally. |
| 4#–6# | Mid-Temperature Charge Test | After 2 hours storage at 45 °C, charging display functioned normally. |
| 4#–6# | High-Temperature Discharge Test | After 2 hours storage at 74 °C, samples powered on normally and performance was normal. |
| 4#–6# | Low-Temperature Discharge Test | After 2 hours storage at -20 °C, samples powered on normally and performance was normal. |
Test Pictures: Low/High Temperature Charge Test images and High/Low Temperature Discharge Test images were captured during testing (see original report appendix).
Overall Result: All 3 samples passed the operating temperature test process. No functional failures were observed. Power-on stability was good and overall performance was satisfactory across all four temperature conditions.
Conclusion
| Field | Details |
|---|---|
| Result | ■ Pass (合格) |
| Standard | Internal Control Standard — samples must operate normally within specified environmental temperatures |
| Conditions Tested | 0 °C (charge), 45 °C (charge), 74 °C (discharge), -20 °C (discharge) — 2 hours per condition |
| Samples Tested | 3 PCS (4#, 5#, 6#) |
| Verdict | All 3 samples passed with no functional failures; stable performance confirmed across all temperature conditions |
Document Information
| Role | Name (Pinyin) | Date |
|---|---|---|
| Tested By | Li Guanghua | 2025-07-22 |
| Checked By | Zhang Ronggui | 2025-07-22 |
| Approved By | Mai Shaoqiang | 2025-07-22 |
| Form Number | BTK-R-Q142/AO | |
Frequently Asked Questions
What temperature range does the HB1 Air Pump support for charging?
The HB1 was tested for charging performance at 0 °C (low temperature) and 45 °C (mid temperature). In both conditions, the charging display functioned normally after 2 hours of thermal stabilization, indicating the product operates reliably within the 0–45 °C charging range.
Can the HB1 Air Pump be used in extreme heat or cold for discharge (operation)?
Yes. The HB1 was tested at 74 °C (high temperature) and -20 °C (low temperature) under discharge conditions. After 2 hours of storage at each temperature, all 3 samples powered on normally and performed as expected, confirming reliable operation across this extreme discharge range.
What test standard was used for this operating temperature test?
This test was conducted against ETENWOLF’s Internal Control Standard. The acceptance criterion requires that samples operate normally within the specified environmental temperature ranges. No external standard such as IEC or UL was referenced for this specific test.
How many samples were tested and what was the overall outcome?
Three samples (IDs 4#, 5#, and 6#) were tested across all four temperature conditions. All three passed without any functional failures. The power-on stability and overall performance were rated as good, resulting in a final verdict of Pass (■ 合格).