Document Overview
Key Findings All 3 samples of the ETENWOLF S0 portable bike pump passed the thermal shock and storage test after 72 hours of cycling between +60°C/80%RH and -20°C with no functional failure or abnormality observed on power-on or charging. Product: ETENWOLF S0 Portable Bike Pump…
- Document type
- Test Report
- Prepared by
- Daniel Wright
- Published
- Last reviewed
- Topics
- Environmental Testing
Key Findings
All 3 samples of the ETENWOLF S0 portable bike pump passed the thermal shock and storage test after 72 hours of cycling between +60°C/80%RH and -20°C with no functional failure or abnormality observed on power-on or charging.
- Product: ETENWOLF S0 Portable Bike Pump
- Test Type: Thermal Shock & High/Low Temperature Storage
- Report No.: 2025070701
- Test Dates: 2025-07-04 to 2025-07-07
- High-Temperature Condition: 60°C, 80% RH, 2 h per cycle
- Low-Temperature Condition: -20°C, 2 h per cycle
- Total Storage Duration: 72 h
- Sample Quantity: 3 pcs
- Verdict: Pass
Test Overview
| Field | Detail |
|---|---|
| Test Type | Thermal Shock & High/Low Temperature Storage (冷热冲击测试) |
| Report No. | 2025070701 |
| Page | 1 |
| Test Dates | 2025-07-04 to 2025-07-07 |
| Product Name | ETENWOLF S0 Portable Bike Pump (S0-自行车充气泵) |
| Manufacturer | BTK |
| Surface Treatment | / |
| Sample Quantity | 3 pcs |
| Test Reason | New product verification |
| Test Purpose | Evaluate the durability of the prototype unit under extreme temperature storage conditions |
| Laboratory Environment | Temperature: 24°C; Humidity: 45% RH |
Test Equipment & Setup
| Parameter | Value |
|---|---|
| Instrument | Constant Temperature and Humidity Testing Machine (恒温恒湿试验机) |
| High-Temperature Condition | 60°C, Humidity 80% RH, duration 2 h |
| Low-Temperature Condition | -20°C, duration 2 h |
| Total Storage Duration | 72 h |
| Post-Storage Functional Test | Power-on check and charging check |
| Test Class / Level | — (not specified) |
Test Procedure
- Pre-test: Record the laboratory ambient conditions (24°C, 45% RH). Visually inspect all 3 sample units and confirm they are in normal working condition before placement.
- High-temperature phase: Place samples inside the constant temperature and humidity chamber. Set chamber to 60°C and 80% RH. Hold for 2 hours.
- Low-temperature phase: Adjust chamber to -20°C (no humidity control required). Hold for 2 hours.
- Cycle repetition: Repeat the high-temperature and low-temperature phases as programmed. Total cumulative storage time shall reach 72 hours per the program control profile.
- Post-test functional check: Remove samples from chamber. Allow recovery at laboratory ambient conditions. Perform power-on test — unit must start normally with no abnormality. Perform charging test — charging function must operate normally.
- Acceptance criteria: No functional failure. Normal power-on. Normal charging. No physical damage attributable to thermal cycling.
Test Data & Results
| Check Item | Condition | Requirement | Sample 1 | Sample 2 | Sample 3 | Result |
|---|---|---|---|---|---|---|
| High-Temperature Storage | 60°C, 80% RH, 2 h | No failure | Pass | Pass | Pass | Pass |
| Low-Temperature Storage | -20°C, 2 h | No failure | Pass | Pass | Pass | Pass |
| Total Storage Duration | 72 h cumulative | Complete cycle | Pass | Pass | Pass | Pass |
| Power-On Function | Post-test ambient recovery | Normal start-up, no abnormality | Pass | Pass | Pass | Pass |
| Charging Function | Post-test ambient recovery | Normal charging | Pass | Pass | Pass | Pass |
Observations: During the test-in-progress phase, the constant temperature and humidity chamber operated per the program control profile. Post-test inspection confirmed that all samples powered on without abnormality and charged normally. The test result states: samples passed under extreme high/low temperature environmental conditions — no performance abnormality, no functional failure (测试结果:样品在极端高低温环境条件下通过,性能无异常,功能无失效).
Conclusion
| Field | Detail |
|---|---|
| Test Standard / Requirement | 60°C/80%RH for 2 h (high temp); -20°C for 2 h (low temp); 72 h total storage; normal power-on and charging required |
| Conditions | Laboratory ambient: 24°C, 45% RH |
| Samples Tested | 3 pcs — ETENWOLF S0 Portable Bike Pump |
| Result | All samples passed. No functional failure. Normal power-on. Normal charging. |
| Verdict | Pass ■ / Fail □ / Reference □ |
Document Information
| Role | Name (Pinyin) |
|---|---|
| Approval (核准) | Mai Shaoqiang |
| Review (审查) | Zhang Ronggui |
| Tester (试验人) | Li Guanghua |
| Form Number (表单编号) | BTK-R-Q-087A/1 |
Frequently Asked Questions
What temperatures were used in the ETENWOLF S0 thermal shock storage test?
The test cycled between a high-temperature phase of 60°C at 80% relative humidity for 2 hours and a low-temperature phase of -20°C for 2 hours. The total cumulative storage duration across all cycles was 72 hours.
Did the ETENWOLF S0 pass the thermal shock and storage test?
Yes. All 3 sample units passed. After completing the 72-hour thermal cycling program, every sample powered on normally with no abnormality and charged normally. No functional failure was recorded.
What equipment was used to conduct the S0 high/low temperature storage test?
A constant temperature and humidity testing machine (恒温恒湿试验机) was used to control both the temperature and humidity conditions throughout the test program.
Why is thermal shock testing important for a portable bike pump?
A portable bike pump may be stored in a car trunk, garage, or outdoors where temperatures can swing from well below freezing to over 60°C in summer. Thermal shock testing confirms that the battery, motor, and electronics inside the S0 remain fully functional across those extremes, giving users confidence the pump will work when they need it.