ETENWOLF S0 Portable Bike Pump Thermal Shock & Storage Test Report (60°C / -20°C, 72 h)

Document Overview

Key Findings All 3 samples of the ETENWOLF S0 portable bike pump passed the thermal shock and storage test after 72 hours of cycling between +60°C/80%RH and -20°C with no functional failure or abnormality observed on power-on or charging. Product: ETENWOLF S0 Portable Bike Pump…

Document type
Test Report
Prepared by
Daniel Wright
Published
Last reviewed
Topics
Environmental Testing

Key Findings

All 3 samples of the ETENWOLF S0 portable bike pump passed the thermal shock and storage test after 72 hours of cycling between +60°C/80%RH and -20°C with no functional failure or abnormality observed on power-on or charging.

  • Product: ETENWOLF S0 Portable Bike Pump
  • Test Type: Thermal Shock & High/Low Temperature Storage
  • Report No.: 2025070701
  • Test Dates: 2025-07-04 to 2025-07-07
  • High-Temperature Condition: 60°C, 80% RH, 2 h per cycle
  • Low-Temperature Condition: -20°C, 2 h per cycle
  • Total Storage Duration: 72 h
  • Sample Quantity: 3 pcs
  • Verdict: Pass

Test Overview

Field Detail
Test Type Thermal Shock & High/Low Temperature Storage (冷热冲击测试)
Report No. 2025070701
Page 1
Test Dates 2025-07-04 to 2025-07-07
Product Name ETENWOLF S0 Portable Bike Pump (S0-自行车充气泵)
Manufacturer BTK
Surface Treatment /
Sample Quantity 3 pcs
Test Reason New product verification
Test Purpose Evaluate the durability of the prototype unit under extreme temperature storage conditions
Laboratory Environment Temperature: 24°C; Humidity: 45% RH

Test Equipment & Setup

Parameter Value
Instrument Constant Temperature and Humidity Testing Machine (恒温恒湿试验机)
High-Temperature Condition 60°C, Humidity 80% RH, duration 2 h
Low-Temperature Condition -20°C, duration 2 h
Total Storage Duration 72 h
Post-Storage Functional Test Power-on check and charging check
Test Class / Level — (not specified)

Test Procedure

  1. Pre-test: Record the laboratory ambient conditions (24°C, 45% RH). Visually inspect all 3 sample units and confirm they are in normal working condition before placement.
  2. High-temperature phase: Place samples inside the constant temperature and humidity chamber. Set chamber to 60°C and 80% RH. Hold for 2 hours.
  3. Low-temperature phase: Adjust chamber to -20°C (no humidity control required). Hold for 2 hours.
  4. Cycle repetition: Repeat the high-temperature and low-temperature phases as programmed. Total cumulative storage time shall reach 72 hours per the program control profile.
  5. Post-test functional check: Remove samples from chamber. Allow recovery at laboratory ambient conditions. Perform power-on test — unit must start normally with no abnormality. Perform charging test — charging function must operate normally.
  6. Acceptance criteria: No functional failure. Normal power-on. Normal charging. No physical damage attributable to thermal cycling.

Test Data & Results

Check Item Condition Requirement Sample 1 Sample 2 Sample 3 Result
High-Temperature Storage 60°C, 80% RH, 2 h No failure Pass Pass Pass Pass
Low-Temperature Storage -20°C, 2 h No failure Pass Pass Pass Pass
Total Storage Duration 72 h cumulative Complete cycle Pass Pass Pass Pass
Power-On Function Post-test ambient recovery Normal start-up, no abnormality Pass Pass Pass Pass
Charging Function Post-test ambient recovery Normal charging Pass Pass Pass Pass

Observations: During the test-in-progress phase, the constant temperature and humidity chamber operated per the program control profile. Post-test inspection confirmed that all samples powered on without abnormality and charged normally. The test result states: samples passed under extreme high/low temperature environmental conditions — no performance abnormality, no functional failure (测试结果:样品在极端高低温环境条件下通过,性能无异常,功能无失效).

Conclusion

Field Detail
Test Standard / Requirement 60°C/80%RH for 2 h (high temp); -20°C for 2 h (low temp); 72 h total storage; normal power-on and charging required
Conditions Laboratory ambient: 24°C, 45% RH
Samples Tested 3 pcs — ETENWOLF S0 Portable Bike Pump
Result All samples passed. No functional failure. Normal power-on. Normal charging.
Verdict Pass ■ / Fail □ / Reference □

Document Information

Role Name (Pinyin)
Approval (核准) Mai Shaoqiang
Review (审查) Zhang Ronggui
Tester (试验人) Li Guanghua
Form Number (表单编号) BTK-R-Q-087A/1

Frequently Asked Questions

What temperatures were used in the ETENWOLF S0 thermal shock storage test?

The test cycled between a high-temperature phase of 60°C at 80% relative humidity for 2 hours and a low-temperature phase of -20°C for 2 hours. The total cumulative storage duration across all cycles was 72 hours.

Did the ETENWOLF S0 pass the thermal shock and storage test?

Yes. All 3 sample units passed. After completing the 72-hour thermal cycling program, every sample powered on normally with no abnormality and charged normally. No functional failure was recorded.

What equipment was used to conduct the S0 high/low temperature storage test?

A constant temperature and humidity testing machine (恒温恒湿试验机) was used to control both the temperature and humidity conditions throughout the test program.

Why is thermal shock testing important for a portable bike pump?

A portable bike pump may be stored in a car trunk, garage, or outdoors where temperatures can swing from well below freezing to over 60°C in summer. Thermal shock testing confirms that the battery, motor, and electronics inside the S0 remain fully functional across those extremes, giving users confidence the pump will work when they need it.