Document Overview
Key Findings The ETENWOLF S1 Portable Tire Inflator passed all six-face drop tests from 100 cm with no functional failure, no housing cracks, and stable power-on operation confirmed after every drop. Product: ETENWOLF S1 Portable Tire Inflator (S1-充气泵) Report No.: 2025081601 Test Date: 2025-08-16 Drop…
- Document type
- Test Report
- Prepared by
- Daniel Wright
- Published
- Last reviewed
- Topics
- Mechanical Reliability
Key Findings
The ETENWOLF S1 Portable Tire Inflator passed all six-face drop tests from 100 cm with no functional failure, no housing cracks, and stable power-on operation confirmed after every drop.
- Product: ETENWOLF S1 Portable Tire Inflator (S1-充气泵)
- Report No.: 2025081601
- Test Date: 2025-08-16
- Drop Height: 100 cm
- Drop Faces: 6 faces (6 drops)
- Sample Quantity: 2 PCS
- Verdict: Pass
Test Overview
| Field | Details |
|---|---|
| Test Type | Drop Test (Mechanical Reliability) |
| Report No. | 2025081601 |
| Test Date | 2025-08-16 |
| Product Name | ETENWOLF S1 Portable Tire Inflator (S1-充气泵) |
| Manufacturer | BTK |
| Surface Treatment | Not specified |
| Sample Quantity | 2 PCS |
| Test Reason | New Product |
| Test Objective | Evaluate the reliability of the finished product by simulating anti-drop impact capability after packaging |
| Laboratory Temperature | 29 °C |
| Laboratory Humidity | 65% RH |
Test Equipment & Setup
| Parameter | Details |
|---|---|
| Instrument Name | Single-Arm Drop Testing Machine (单臂跌落试验机) |
| Drop Height | 100 cm |
| Number of Drops | 6 faces (6 drops) |
| Sample Weight | Not recorded in report |
| Test Class | Not recorded in report |
Test Procedure
- Pre-Test: Confirm laboratory environment — temperature 29 °C, humidity 65% RH. Verify sample quantity (2 PCS). Power on each unit and confirm normal start-up, display, LED brightness, and charging function prior to testing.
- Setup: Mount sample on the single-arm drop testing machine. Set drop height to 100 cm.
- Procedure: Execute six consecutive drops, one per face (Face 1 through Face 6), from 100 cm onto a hard surface. Record observations after each drop.
- Post-Test Inspection: After all six drops, power on the unit and verify: normal start-up with no display anomalies, normal LED brightness, no lens cracking, no housing cracks, no structural component disengagement, and normal charging function.
- Acceptance Criteria: No functional failure; no housing cracks or splits.
Test Data & Results
| Drop No. | Face | Observation |
|---|---|---|
| 1 | Face 1 | Normal power-on, no display anomalies (开机正常无缺画) |
| 2 | Face 2 | LED brightness normal (LED灯亮度正常) |
| 3 | Face 3 | Lens intact, no cracking (镜片无破裂) |
| 4 | Face 4 | No appearance cracks, no structural component disengagement (外观无开裂,结构件无脱扣) |
| 5 | Face 5 | No anomaly recorded |
| 6 | Face 6 | Charging function normal (充电正常) |
Overall Test Result: Samples passed the drop test. No appearance damage observed. Power-on operation stable. No functional failure detected.
Conclusion
| Field | Details |
|---|---|
| Result | Pass ■ / Fail □ / Reference □ |
| Test Conditions | 100 cm drop height, 6 faces, 29 °C / 65% RH |
| Samples Tested | 2 PCS — ETENWOLF S1 Portable Tire Inflator |
| Standard / Requirement | No functional failure; no housing cracks |
| Verdict | PASS |
Document Information
| Role | Name (Pinyin) |
|---|---|
| Approval (核准) | Mai Shaoqiang |
| Review (审查) | Zhang Ronggui |
| Tester (试验人) | Li Guanghua |
| Form Number | BTK-R-Q-087A/1 |
| Report No. | 2025081601 |
| Page | 1.0 |
Frequently Asked Questions
What drop height was used in the ETENWOLF S1 drop test?
The ETENWOLF S1 was tested at a drop height of 100 cm (approximately 39 inches) using a single-arm drop testing machine, covering all six faces of the unit.
Did the ETENWOLF S1 pass the drop test?
Yes. Both samples passed all six-face drops from 100 cm with no functional failure, no housing cracks, no lens damage, and stable power-on and charging performance confirmed after testing.
How many samples were tested in the S1 drop test?
Two production samples (2 PCS) of the ETENWOLF S1 Portable Tire Inflator were used in this drop test, conducted on 2025-08-16.
Who approved the ETENWOLF S1 drop test report?
The report was approved by Mai Shaoqiang, reviewed by Zhang Ronggui, and conducted by tester Li Guanghua, under form number BTK-R-Q-087A/1.
Related Products
Explore the full ETENWOLF portable tire inflator lineup and related test documentation:
- ETENWOLF S1 Portable Tire Inflator — Product Page
- ETENWOLF S1 — Sheet1 Test Report (Sibling Sheet)