CE-EMC Test Report for ETENWOLF P100 Ball Pump – Report No. WTH25X04098552E

Document Overview

Document Overview This page presents the CE Electromagnetic Compatibility (EMC) test report issued for the ETENWOLF P100 Ball Pump. The document is an official test report — not a certificate — prepared by an accredited third-party laboratory following the completion of both emission and immunity…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
European Union: CE / RoHS / REACH / WEEE

Document Overview

This page presents the CE Electromagnetic Compatibility (EMC) test report issued for the ETENWOLF P100 Ball Pump. The document is an official test report — not a certificate — prepared by an accredited third-party laboratory following the completion of both emission and immunity evaluations required for CE marking under the EMC Directive.

Field Detail
Document Type CE-EMC Test Report
Reference Number WTH25X04098552E
Test Report Form No. WTX_EN IEC 55014_1_2021_A
Issuing Laboratory Waltek Testing Group (Shenzhen) Co., Ltd.
Date of Sample Receipt 2025-04-18
Date of Test 2025-04-18 to 2025-04-22
Date of Issue 2025-04-23
Report Version Rev.00 (Original)
Overall Test Result Pass

The test report covers electromagnetic emission (EMI) and electromagnetic immunity (EMS) evaluations. Results are valid solely for the production sample tested and may not be reproduced in part without prior written permission from Waltek Testing Group.

Product Information

The equipment under test (EUT) is the ETENWOLF P100 Ball Pump, a compact cordless inflation tool designed for sports balls and similar applications. The product is manufactured and marketed by Guangdong Bestek Technology Co., Ltd.

Attribute Value
Product Name Ball Pump
Model Number P100
Trade Name
Additional Models
Applicant Guangdong Bestek Technology Co., Ltd.
Manufacturer Guangdong Bestek Technology Co., Ltd.
Manufacturer Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China
Power Supply Input DC 5V (via adapter); Battery: DC 3.7V
Power Adapter Xiaomi MDY-12-EQ (S/N: QA622020106645G) — auxiliary equipment
Highest Clock Frequency Below 108 MHz
Rated Power Not specified
Rated Current Not specified

The sample tested was drawn from production and provided directly by the manufacturer. Two operating modes were configured during testing to capture the full emission and immunity profile of the device.

Key Details

Testing was conducted across two operating modes and covered both conducted and radiated emission measurements as well as a full suite of immunity tests. The following tables summarise the test configuration and measurement uncertainty values declared by the laboratory.

Test Modes (EUT Configuration)

Mode ID Title Description
TM1 Charge Mode DC 5V input via adapter (AC 230V / 50Hz)
TM2 Working Mode Battery DC 3.7V

Measurement Uncertainty

Test Item Measurement Uncertainty
Conducted Emissions — AC Mains 9kHz to 150kHz ±3.74 dB
Conducted Emissions — AC Mains 150kHz to 30MHz ±3.34 dB
Radiated Emissions — 30MHz to 200MHz ±4.52 dB
Radiated Emissions — 200MHz to 1000MHz ±5.56 dB

Test Scope Summary

Section Test Category Description
3.1 EMI — Emission Disturbance voltage from AC mains port
3.2 EMI — Emission Radiated disturbance (30MHz – 1GHz)
4.1 EMS — Immunity Electrostatic discharge (ESD)
4.2 EMS — Immunity Radio frequency electromagnetic fields
4.3 EMS — Immunity Fast transients for AC power ports (EFT/Burst)
4.4 EMS — Immunity Surges for AC power ports
4.5 EMS — Immunity Injected currents for AC power ports (conducted RF immunity)
4.6 EMS — Immunity Voltage dips and short interruptions

Standards & Compliance

The P100 Ball Pump was evaluated against the following harmonised European standards applicable to household appliances and electric tools under the EU EMC Directive 2014/30/EU.

Standard Title Scope
EN IEC 55014-1:2021 Electromagnetic Compatibility — Requirements for household appliances, electric tools and similar apparatus — Part 1: Emission Limits and measurement methods for electromagnetic emission from equipment in the frequency range 9kHz to 400GHz
EN IEC 55014-2:2021 Electromagnetic Compatibility — Requirements for household appliances, electric tools and similar apparatus — Part 2: Immunity — Product family standard Immunity requirements covering ESD, radiated RF fields, EFT/burst, surges, conducted RF immunity, and voltage dips

Compliance with these standards supports CE marking of the product for sale in the European Economic Area. The manufacturer bears ongoing responsibility for maintaining compliance; any product modification that could affect emission or immunity levels must be re-evaluated to confirm continued conformity.

Validity & Certification Body

This test report was prepared by Waltek Testing Group (Shenzhen) Co., Ltd., an accredited EMC and safety testing laboratory. The report is valid for the specific production sample submitted and is not transferable to other units or model variants without re-testing.

Field Detail
Laboratory Name Waltek Testing Group (Shenzhen) Co., Ltd.
Laboratory Website http://www.waltek.com.cn
Laboratory Address 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70, Bao’an District, Shenzhen, Guangdong, China
Telephone +86-755-33663308
Fax +86-755-33663309
Email [email protected]
Tested By Toby Zhang — Project Engineer
Approved By Evan Cai — Manager
Date of Issue 2025-04-23
Report Version Rev.00 (Original, no subsequent revisions)
Total Pages 37

The report is invalidated if the laboratory’s specific stamp or the approver’s signature is absent. Partial reproduction of this report is prohibited without prior written consent from Waltek Testing Group.

Frequently Asked Questions

What does this CE-EMC test report confirm about the P100 Ball Pump?

The report confirms that the ETENWOLF P100 Ball Pump passed both electromagnetic emission (EMI) and electromagnetic immunity (EMS) evaluations conducted by Waltek Testing Group. The device complies with EN IEC 55014-1:2021 and EN IEC 55014-2:2021, which are the harmonised standards required for CE marking under the EU EMC Directive 2014/30/EU.

What is the difference between EMI and EMS testing covered in this report?

EMI (Electromagnetic Interference / Emission) testing measures the level of electromagnetic noise the device generates — both conducted noise on the power line and radiated noise through the air — to ensure it does not interfere with other equipment. EMS (Electromagnetic Susceptibility / Immunity) testing verifies that the device continues to operate correctly when exposed to external electromagnetic disturbances such as electrostatic discharge, RF fields, power line surges, and voltage dips.

Does this report cover all CE certification requirements for the P100?

No. This report addresses only the EMC (electromagnetic compatibility) requirements. CE marking for a product like the P100 Ball Pump may also require evaluation under additional directives, such as the Low Voltage Directive (LVD) or the Radio Equipment Directive (RED), depending on the product’s features. Separate test reports or declarations would cover those requirements.

If the P100 design is modified, is this test report still valid?

Not necessarily. As stated in the report, any modification to the product that could affect its emission or immunity characteristics must be re-evaluated to confirm that compliance has been maintained. The manufacturer — Guangdong Bestek Technology Co., Ltd. — is responsible for ensuring ongoing conformity after any design change.

Related Documents

The following certification and compliance documents are typically required alongside a CE-EMC test report for a cordless inflation tool like the ETENWOLF P100 Ball Pump. These documents together support a complete CE Declaration of Conformity and market access in key regions.

Document Type Applicable Standard / Directive Relevance to P100
CE-LVD Test Report EU Low Voltage Directive 2014/35/EU; EN 62368-1 or EN 60335-1 Electrical safety evaluation for the DC-powered pump and charging circuit
CE Declaration of Conformity (DoC) EU EMC Directive 2014/30/EU Manufacturer’s formal declaration referencing this EMC report
UN38.3 Battery Test Report UN38.3 Transport safety certification for the built-in DC 3.7V lithium battery
RoHS Compliance Report RoHS Directive 2011/65/EU Restriction of hazardous substances in electrical and electronic equipment
REACH SVHC Declaration REACH Regulation (EC) No 1907/2006 Substance of Very High Concern compliance declaration for EU market
FCC ID / SDOC Report FCC Part 15 Radio frequency emission compliance for the US market
KC Certification Korean KC Mark — Radio Waves Act Electromagnetic compatibility certification required for the Korean market

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22
Document Page 23
Document Page 24
Document Page 25
Document Page 26
Document Page 27
Document Page 28
Document Page 29
Document Page 30
Document Page 31
Document Page 32
Document Page 33
Document Page 34
Document Page 35
Document Page 36
Document Page 37