Document Overview
Document Overview This page presents the official UN38.3 Test Report issued by Waltek Testing Group Co., Ltd. (深圳沃特检验集团股份有限公司) for a lithium-ion battery pack associated with the HB1 product. The report covers mandatory transport safety testing required by the United Nations Recommendations on the Transport of…
- Document type
- Certification Report
- Prepared by
- Michelle Torres
- Published
- Last reviewed
- Topics
- International Transportation: CB / MSDS / UN38.3
Document Overview
This page presents the official UN38.3 Test Report issued by Waltek Testing Group Co., Ltd. (深圳沃特检验集团股份有限公司) for a lithium-ion battery pack associated with the HB1 product. The report covers mandatory transport safety testing required by the United Nations Recommendations on the Transport of Dangerous Goods.
| Field | Details |
|---|---|
| Report Number | WTH25D09256005B |
| Document Type | UN38.3 Test Report |
| Issuing Body | Waltek Testing Group Co., Ltd. |
| Test Standard | ST/SG/AC.10/11/Rev.8 Section 38.3 (Eighth Revision Edition Amendment) |
| Date of Receipt of Sample | 2025-09-25 |
| Date of Test | 2025-10-09 to 2025-10-20 |
| Date of Issue | 2025-10-22 |
| Overall Test Result | PASS — The submitted samples comply with the above standards |
Product Information
The battery pack tested under this report is the internal power cell used in the HB1 portable inflation tool. Full product specifications are listed below.
| Parameter | Value |
|---|---|
| Product Name | Lithium-ion Battery Pack |
| Model Number | 1S1P-1100 |
| Cell Model | 18350 |
| Configuration | 1 cell, 1S1P |
| Rated Voltage | 3.7 V |
| Rated Capacity | 1100 mAh |
| Energy | 4.07 Wh |
| Shape | Cylindrical |
| Dimensions | 19.4 mm × 33.7 mm |
| Mass | Approx. 26.2 g |
| Standard Charge Current | 550 mA |
| Maximum Charge Voltage | 5 V |
| Maximum Charge Current | 1100 mA |
| Standard Discharge Current | 550 mA |
| Maximum Discharge Current | 11000 mA |
| Discharge Cut-off Voltage | 2.75 V |
| Trade Mark | N/A |
The applicant and manufacturer is Guangdong Bestek Technology Co., LTD, located at No. 1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China.
Key Details
Testing was conducted in accordance with ST/SG/AC.10/11/Rev.8 Section 38.3. The following table summarises the test items and sample configurations used during evaluation of the HB1 battery pack.
| Test Item | Sample Numbers | Sample State |
|---|---|---|
| T1–T5 | B01# – B05# | 1st charge/discharge cycle, fully charged state |
| T1–T5 | B06# – B10# | After 25 cycles, fully charged state |
| T6 | C01# – C05# | 1st cycle at 50% of design rated capacity |
| T6 | C06# – C10# | After 25 cycles at 50% of design rated capacity |
| T7 | B11# – B14# | 1st cycle, fully charged state |
| T7 | B15# – B18# | After 25 cycles, fully charged state |
| T8 | C11# – C20# | 1st cycle, fully discharged state |
| T8 | C21# – C30# | After 25 cycles, fully discharged state |
Test environment conditions were maintained at an ambient temperature of 20 °C – 25 °C and ambient humidity of 45% – 75%. Subcontracted testing was not applicable. The report was prepared by Jason Zhen (甄锦炎), reviewed by Jack Chen (陈咏松), and approved by Deval Qin (秦林伟).
Standards & Compliance
The HB1 battery pack was evaluated against the mandatory transport safety requirements for lithium cells and batteries under the following standard:
| Standard | Scope |
|---|---|
| ST/SG/AC.10/11/Rev.8, Section 38.3 | UN Manual of Tests and Criteria, Eighth Revision Edition Amendment — lithium battery transport safety tests |
UN38.3 defines a series of tests (T1 through T8) that lithium batteries must pass before they may be transported by air, sea, or land as dangerous goods. These tests include altitude simulation, thermal testing, vibration, shock, external short circuit, impact/crush, overcharge, and forced discharge. All applicable test items for the 1S1P-1100 cylindrical cell pack returned a Pass result. The overall conclusion of the report confirms that the submitted samples comply with the relevant requirements of the standard.
Validity & Certification Body
This test report was issued on 2025-10-22 and covers the battery model 1S1P-1100 (18350 cylindrical cell, 3.7 V / 1100 mAh) as used in the HB1. Report validity is subject to the issuing laboratory’s standard terms: the report may not be partially reproduced without prior written permission, and it is invalid if altered, unsigned by the approver, or lacking the official accreditation stamp of the institute.
| Field | Details |
|---|---|
| Report Number | WTH25D09256005B |
| Date of Issue | 2025-10-22 |
| Testing Laboratory | Waltek Testing Group Co., Ltd. (深圳沃特检验集团股份有限公司) |
| Lab Address | No. 77, Houjie Section, Guantai Rd., Houjie Town, Dongguan City, Guangdong, China |
| Lab Website | http://www.waltek.com.cn |
| Lab Tel | +86-769-2267 6998 |
| Lab Fax | +86-769-2267 6828 |
| Lab Email | [email protected] |
| Tested By | Jason Zhen (甄锦炎) |
| Reviewed By | Jack Chen (陈咏松) |
| Approved By | Deval Qin (秦林伟) |
| Internal Reference | WT-510-201-02-B |
Frequently Asked Questions
- What is UN38.3 and why is it required for the HB1 battery?
-
UN38.3 is the section of the United Nations Manual of Tests and Criteria that specifies the safety tests lithium cells and batteries must pass before international transport. Without a valid UN38.3 test report, carriers (airlines, shipping companies) are legally prohibited from accepting the battery for transport. The HB1 battery pack (1S1P-1100) passed all applicable UN38.3 tests as documented in report WTH25D09256005B, confirming it may be shipped safely.
- Which edition of the UN Manual was used for this report?
-
Testing was conducted against the Eighth Revision Edition Amendment of the UN Manual of Tests and Criteria (ST/SG/AC.10/11/Rev.8, Section 38.3), which is the current authoritative edition at the time of test.
- What are the key electrical specifications of the HB1 battery pack tested?
-
The battery pack tested is a cylindrical 18350 cell in a 1S1P configuration with a rated voltage of 3.7 V, rated capacity of 1100 mAh, and energy of 4.07 Wh. Maximum charge voltage is 5 V, maximum charge current is 1100 mA, and maximum discharge current is 11000 mA.
- Who conducted the UN38.3 testing and is Waltek an accredited laboratory?
-
Testing was performed by Waltek Testing Group Co., Ltd., based in Dongguan, Guangdong, China. Waltek is a nationally accredited third-party testing institute. The report carries the signatures of the tester, reviewer, and approver, and is stamped with the institute’s official accreditation seal to confirm its validity for regulatory and logistics purposes.
Related Documents
For a complete compliance picture of the HB1 and its integrated battery system, the following related certification and test documents are recommended:
- IEC 62133 — Safety requirements for portable sealed secondary lithium cells and batteries for use in portable applications.
- CE / LVD & EMC Declarations — Required for sale of the HB1 in the European Economic Area, covering electrical safety and electromagnetic compatibility.
- RoHS Compliance Report — Restriction of Hazardous Substances declaration for the battery and product assembly, required for EU and many global markets.
- REACH Declaration — Confirms compliance with EU REACH regulation regarding substances of very high concern (SVHC) in the product and battery.
- FCC Declaration of Conformity — Required for wireless or electronic products sold in the United States market.
- PSE / KC Certification — Applicable safety certifications for the Japanese and South Korean markets respectively, if applicable to market scope.
- IEC 60086 / IEC 61960 — Primary and secondary lithium cell standards covering performance and dimensional specifications for the 18350 cylindrical cell format.