Document Overview
Document Overview This article presents the CE Electromagnetic Compatibility (EMC) Test Report issued for the ETENWOLF V3 Air Inflator. The report was prepared by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited third-party EMC testing laboratory located in Longgang District, Shenzhen, Guangdong, China. Field…
- Document type
- Certification Report
- Prepared by
- Michelle Torres
- Published
- Last reviewed
- Topics
- European Union: CE / RoHS / REACH / WEEE
Document Overview
This article presents the CE Electromagnetic Compatibility (EMC) Test Report issued for the ETENWOLF V3 Air Inflator. The report was prepared by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited third-party EMC testing laboratory located in Longgang District, Shenzhen, Guangdong, China.
| Field | Details |
|---|---|
| Reference Number | WTH25H05129146E |
| Document Type | CE-EMC Test Report |
| Test Report Form No. | TRF EN IEC 55014-1: 2021-EMC-001-V01 |
| Internal Reference | HCT/RF-23-21 |
| Date of Sample Receipt | 2025-05-22 |
| Date of Testing | 2025-05-26 to 2025-05-27 |
| Date of Issue | 2025-05-29 |
| Overall Test Result | Pass |
The report covers conducted disturbance at mains terminals, disturbance power in the frequency range, and radiated disturbances, confirming that the product meets all applicable CE-EMC requirements for placing on the European market.
Product Information
The Equipment Under Test (EUT) evaluated in this CE-EMC report is the ETENWOLF V3 Air Inflator, a portable cordless inflation tool designed for inflating tyres, sports equipment, and other inflatable items.
| Attribute | Details |
|---|---|
| Product Name | Air Inflator |
| Model Number | V3 |
| Brand | ETENWOLF |
| Applicant | Guangdong Bestek Technology Co., Ltd. |
| Manufacturer | Guangdong Bestek Technology Co., Ltd. |
| Manufacturer Address | No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China |
The V3 Air Inflator is classified as a household and similar electrical appliance, falling within the product scope of EN IEC 55014 series standards. The device was submitted in its standard production configuration for all EMC measurements.
Key Details
The test report covers four primary EMC measurement categories as required by the applicable EN IEC 55014 series and EN IEC 61000 series standards. The following table summarises the test scope and results for each section.
| Test Section | Test Category | Standard Applied | Result |
|---|---|---|---|
| Section 3 | Conducted Disturbance at Mains Terminals | EN IEC 55014-1: 2021 | Pass |
| Section 4 | Disturbance Power in the Frequency Range | EN IEC 55014-1: 2021 | Pass |
| Section 5 | Radiated Disturbances | EN IEC 55014-1: 2021 | Pass |
| Section 6 | Harmonic Current Emissions | EN IEC 61000-3-2: 2019+A1:2021 | Pass |
| Section 7 | Voltage Fluctuations and Flicker | EN 61000-3-3: 2013+A2:2021 | Pass |
For each test category, measurement uncertainty was documented in accordance with laboratory accreditation requirements. The test system configuration, EUT setup, instrument setup, test procedure, and full measurement data were recorded across 54 pages in the original report. All measured values were confirmed to be within the permitted limits defined by the respective standards.
| Report Detail | Value |
|---|---|
| Total Report Pages | 54 |
| Prepared By | Snow Zeng |
| Approved By | Tony Wu |
| Laboratory Contact | [email protected] |
| Laboratory Tel | 0755-84616666 |
| Service Tel | 400-0066-989 |
Standards & Compliance
The ETENWOLF V3 Air Inflator was tested against the following European harmonised standards as part of its CE-EMC conformity assessment. These standards are published and maintained by IEC and adopted in the EU through CENELEC.
| Standard | Title / Scope | Relevance |
|---|---|---|
| EN IEC 55014-1: 2021 | Electromagnetic Compatibility — Requirements for household appliances, electric tools and similar apparatus — Part 1: Emission | Conducted and radiated emission limits |
| EN IEC 55014-2: 2021 | Electromagnetic Compatibility — Requirements for household appliances, electric tools and similar apparatus — Part 2: Immunity | Immunity requirements |
| EN IEC 61000-3-2: 2019+A1:2021 | Electromagnetic Compatibility — Limits for harmonic current emissions (equipment input current ≤16 A per phase) | Harmonic current emission limits |
| EN 61000-3-3: 2013+A2:2021 | Electromagnetic Compatibility — Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems | Voltage fluctuation and flicker limits |
Compliance with these standards supports the CE marking of the V3 under the EU Radio Equipment Directive (RED) and/or the Electromagnetic Compatibility Directive (2014/30/EU). The test report form reference TRF EN IEC 55014-1: 2021-EMC-001-V01 confirms alignment with the current edition of the standard.
Validity & Certification Body
This test report was issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited EMC testing laboratory operating under internationally recognised quality and technical standards.
| Detail | Information |
|---|---|
| Issuing Laboratory | Waltek Testing Group HCT (Shenzhen) Co., Ltd. |
| Laboratory Address | Building B, Tianji Industrial Park, 1/F. & 2/F. & 3/F., No.30-9, Laiyin Road, Xinsheng Community, Longgang Subdistrict, Longgang District, Shenzhen, Guangdong, China |
| Report Reference No. | WTH25H05129146E |
| Date of Issue | 2025-05-29 |
| Test Dates | 2025-05-26 to 2025-05-27 |
| Prepared By | Snow Zeng |
| Approved By | Tony Wu |
| Contact Email | [email protected] |
The report is valid for the specific product model, configuration, and firmware version submitted for testing. Any significant design change, change in components, or change in the intended market may require re-testing. The report supports CE-EMC conformity declarations for the ETENWOLF V3 Air Inflator and can be referenced in the product’s EU Declaration of Conformity (DoC).
Frequently Asked Questions
- What does the CE-EMC test report WTH25H05129146E confirm for the ETENWOLF V3?
-
Report WTH25H05129146E confirms that the ETENWOLF V3 Air Inflator passed all required electromagnetic compatibility (EMC) emission and immunity tests conducted by Waltek Testing Group HCT (Shenzhen) Co., Ltd. The device met the limits set by EN IEC 55014-1: 2021, EN IEC 55014-2: 2021, EN IEC 61000-3-2: 2019+A1:2021, and EN 61000-3-3: 2013+A2:2021, qualifying it for CE marking in European markets.
- Which EMC standards were applied during testing of the V3 Air Inflator?
-
The V3 was tested against four harmonised European standards: EN IEC 55014-1: 2021 for emission limits, EN IEC 55014-2: 2021 for immunity requirements, EN IEC 61000-3-2: 2019+A1:2021 for harmonic current emissions, and EN 61000-3-3: 2013+A2:2021 for voltage fluctuations and flicker. All four test categories returned a Pass result.
- Who conducted the CE-EMC testing for the ETENWOLF V3 and when?
-
Testing was performed by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited third-party laboratory based in Shenzhen, China. The sample was received on 2025-05-22, testing was carried out from 2025-05-26 to 2025-05-27, and the report was issued on 2025-05-29. The report was prepared by Snow Zeng and approved by Tony Wu.
- Does a passed CE-EMC report mean the ETENWOLF V3 can be sold across all EU member states?
-
A passed CE-EMC test report is a key technical document supporting the CE marking process, but it is one component of full CE conformity. The manufacturer must also complete an EU Declaration of Conformity (DoC) and ensure compliance with all other applicable directives (such as the Low Voltage Directive or Battery Directive, depending on the product configuration). Once CE marking is properly affixed, the V3 may be placed on the market throughout the European Economic Area (EEA).
Related Documents
The CE-EMC test report is one part of the complete compliance documentation package for the ETENWOLF V3 Air Inflator. The following related certification and test document types are typically required or recommended for this product category:
- CE-LVD Test Report — Low Voltage Directive safety testing under EN 60335-1 and EN 60335-2-29, covering electrical safety for battery-powered appliances.
- UN 38.3 Test Report — Transportation safety testing for lithium-ion battery cells and packs, required for air and sea freight compliance.
- RoHS Compliance Report — Restriction of Hazardous Substances testing confirming the absence of restricted materials such as lead, mercury, cadmium, and hexavalent chromium under EU RoHS Directive 2011/65/EU.
- REACH SVHC Declaration — Declaration confirming compliance with REACH Regulation (EC) No 1907/2006 regarding Substances of Very High Concern.
- FCC ID / SDOC Report — Federal Communications Commission compliance documentation for sale in the United States market.
- KC Certification — Korean Certification mark compliance documentation required for sale in the Republic of Korea market.
- EU Declaration of Conformity (DoC) — The manufacturer’s formal declaration referencing all applicable directives and harmonised standards, including this EMC test report.
Document Pages