CE-EMC Test Report for ETENWOLF V3 Air Inflator — Report WTH25H05129146E

Document Overview

Document Overview This article presents the CE Electromagnetic Compatibility (EMC) Test Report issued for the ETENWOLF V3 Air Inflator. The report was prepared by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited third-party EMC testing laboratory located in Longgang District, Shenzhen, Guangdong, China. Field…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
European Union: CE / RoHS / REACH / WEEE

Document Overview

This article presents the CE Electromagnetic Compatibility (EMC) Test Report issued for the ETENWOLF V3 Air Inflator. The report was prepared by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited third-party EMC testing laboratory located in Longgang District, Shenzhen, Guangdong, China.

Field Details
Reference Number WTH25H05129146E
Document Type CE-EMC Test Report
Test Report Form No. TRF EN IEC 55014-1: 2021-EMC-001-V01
Internal Reference HCT/RF-23-21
Date of Sample Receipt 2025-05-22
Date of Testing 2025-05-26 to 2025-05-27
Date of Issue 2025-05-29
Overall Test Result Pass

The report covers conducted disturbance at mains terminals, disturbance power in the frequency range, and radiated disturbances, confirming that the product meets all applicable CE-EMC requirements for placing on the European market.

Product Information

The Equipment Under Test (EUT) evaluated in this CE-EMC report is the ETENWOLF V3 Air Inflator, a portable cordless inflation tool designed for inflating tyres, sports equipment, and other inflatable items.

Attribute Details
Product Name Air Inflator
Model Number V3
Brand ETENWOLF
Applicant Guangdong Bestek Technology Co., Ltd.
Manufacturer Guangdong Bestek Technology Co., Ltd.
Manufacturer Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China

The V3 Air Inflator is classified as a household and similar electrical appliance, falling within the product scope of EN IEC 55014 series standards. The device was submitted in its standard production configuration for all EMC measurements.

Key Details

The test report covers four primary EMC measurement categories as required by the applicable EN IEC 55014 series and EN IEC 61000 series standards. The following table summarises the test scope and results for each section.

Test Section Test Category Standard Applied Result
Section 3 Conducted Disturbance at Mains Terminals EN IEC 55014-1: 2021 Pass
Section 4 Disturbance Power in the Frequency Range EN IEC 55014-1: 2021 Pass
Section 5 Radiated Disturbances EN IEC 55014-1: 2021 Pass
Section 6 Harmonic Current Emissions EN IEC 61000-3-2: 2019+A1:2021 Pass
Section 7 Voltage Fluctuations and Flicker EN 61000-3-3: 2013+A2:2021 Pass

For each test category, measurement uncertainty was documented in accordance with laboratory accreditation requirements. The test system configuration, EUT setup, instrument setup, test procedure, and full measurement data were recorded across 54 pages in the original report. All measured values were confirmed to be within the permitted limits defined by the respective standards.

Report Detail Value
Total Report Pages 54
Prepared By Snow Zeng
Approved By Tony Wu
Laboratory Contact [email protected]
Laboratory Tel 0755-84616666
Service Tel 400-0066-989

Standards & Compliance

The ETENWOLF V3 Air Inflator was tested against the following European harmonised standards as part of its CE-EMC conformity assessment. These standards are published and maintained by IEC and adopted in the EU through CENELEC.

Standard Title / Scope Relevance
EN IEC 55014-1: 2021 Electromagnetic Compatibility — Requirements for household appliances, electric tools and similar apparatus — Part 1: Emission Conducted and radiated emission limits
EN IEC 55014-2: 2021 Electromagnetic Compatibility — Requirements for household appliances, electric tools and similar apparatus — Part 2: Immunity Immunity requirements
EN IEC 61000-3-2: 2019+A1:2021 Electromagnetic Compatibility — Limits for harmonic current emissions (equipment input current ≤16 A per phase) Harmonic current emission limits
EN 61000-3-3: 2013+A2:2021 Electromagnetic Compatibility — Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems Voltage fluctuation and flicker limits

Compliance with these standards supports the CE marking of the V3 under the EU Radio Equipment Directive (RED) and/or the Electromagnetic Compatibility Directive (2014/30/EU). The test report form reference TRF EN IEC 55014-1: 2021-EMC-001-V01 confirms alignment with the current edition of the standard.

Validity & Certification Body

This test report was issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited EMC testing laboratory operating under internationally recognised quality and technical standards.

Detail Information
Issuing Laboratory Waltek Testing Group HCT (Shenzhen) Co., Ltd.
Laboratory Address Building B, Tianji Industrial Park, 1/F. & 2/F. & 3/F., No.30-9, Laiyin Road, Xinsheng Community, Longgang Subdistrict, Longgang District, Shenzhen, Guangdong, China
Report Reference No. WTH25H05129146E
Date of Issue 2025-05-29
Test Dates 2025-05-26 to 2025-05-27
Prepared By Snow Zeng
Approved By Tony Wu
Contact Email [email protected]

The report is valid for the specific product model, configuration, and firmware version submitted for testing. Any significant design change, change in components, or change in the intended market may require re-testing. The report supports CE-EMC conformity declarations for the ETENWOLF V3 Air Inflator and can be referenced in the product’s EU Declaration of Conformity (DoC).

Frequently Asked Questions

What does the CE-EMC test report WTH25H05129146E confirm for the ETENWOLF V3?

Report WTH25H05129146E confirms that the ETENWOLF V3 Air Inflator passed all required electromagnetic compatibility (EMC) emission and immunity tests conducted by Waltek Testing Group HCT (Shenzhen) Co., Ltd. The device met the limits set by EN IEC 55014-1: 2021, EN IEC 55014-2: 2021, EN IEC 61000-3-2: 2019+A1:2021, and EN 61000-3-3: 2013+A2:2021, qualifying it for CE marking in European markets.

Which EMC standards were applied during testing of the V3 Air Inflator?

The V3 was tested against four harmonised European standards: EN IEC 55014-1: 2021 for emission limits, EN IEC 55014-2: 2021 for immunity requirements, EN IEC 61000-3-2: 2019+A1:2021 for harmonic current emissions, and EN 61000-3-3: 2013+A2:2021 for voltage fluctuations and flicker. All four test categories returned a Pass result.

Who conducted the CE-EMC testing for the ETENWOLF V3 and when?

Testing was performed by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited third-party laboratory based in Shenzhen, China. The sample was received on 2025-05-22, testing was carried out from 2025-05-26 to 2025-05-27, and the report was issued on 2025-05-29. The report was prepared by Snow Zeng and approved by Tony Wu.

Does a passed CE-EMC report mean the ETENWOLF V3 can be sold across all EU member states?

A passed CE-EMC test report is a key technical document supporting the CE marking process, but it is one component of full CE conformity. The manufacturer must also complete an EU Declaration of Conformity (DoC) and ensure compliance with all other applicable directives (such as the Low Voltage Directive or Battery Directive, depending on the product configuration). Once CE marking is properly affixed, the V3 may be placed on the market throughout the European Economic Area (EEA).

Related Documents

The CE-EMC test report is one part of the complete compliance documentation package for the ETENWOLF V3 Air Inflator. The following related certification and test document types are typically required or recommended for this product category:

  • CE-LVD Test Report — Low Voltage Directive safety testing under EN 60335-1 and EN 60335-2-29, covering electrical safety for battery-powered appliances.
  • UN 38.3 Test Report — Transportation safety testing for lithium-ion battery cells and packs, required for air and sea freight compliance.
  • RoHS Compliance Report — Restriction of Hazardous Substances testing confirming the absence of restricted materials such as lead, mercury, cadmium, and hexavalent chromium under EU RoHS Directive 2011/65/EU.
  • REACH SVHC Declaration — Declaration confirming compliance with REACH Regulation (EC) No 1907/2006 regarding Substances of Very High Concern.
  • FCC ID / SDOC Report — Federal Communications Commission compliance documentation for sale in the United States market.
  • KC Certification — Korean Certification mark compliance documentation required for sale in the Republic of Korea market.
  • EU Declaration of Conformity (DoC) — The manufacturer’s formal declaration referencing all applicable directives and harmonised standards, including this EMC test report.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22
Document Page 23
Document Page 24
Document Page 25
Document Page 26
Document Page 27
Document Page 28
Document Page 29
Document Page 30
Document Page 31
Document Page 32
Document Page 33
Document Page 34
Document Page 35
Document Page 36
Document Page 37
Document Page 38
Document Page 39
Document Page 40
Document Page 41
Document Page 42
Document Page 43
Document Page 44
Document Page 45
Document Page 46
Document Page 47
Document Page 48
Document Page 49
Document Page 50
Document Page 51
Document Page 52
Document Page 53
Document Page 54