Document Overview
Document Overview This article covers the official CE Low Voltage Directive (LVD) test report issued by Waltek Testing Group (Shenzhen) Co., Ltd. for the ETENWOLF S6C inflator pump. The report reference number is WTH25X07183681J, issued on 2025-07-23, covering tests conducted from 2025-07-14 to 2025-07-22. The…
- Document type
- Certification Report
- Prepared by
- Michelle Torres
- Published
- Last reviewed
- Topics
- European Union: CE / RoHS / REACH / WEEE
Document Overview
This article covers the official CE Low Voltage Directive (LVD) test report issued by Waltek Testing Group (Shenzhen) Co., Ltd. for the ETENWOLF S6C inflator pump. The report reference number is WTH25X07183681J, issued on 2025-07-23, covering tests conducted from 2025-07-14 to 2025-07-22. The document certifies compliance with applicable EU safety directives for household and similar electrical appliances intended for indoor use.
| Field | Detail |
|---|---|
| Document Type | CE-LVD Test Report |
| Reference No. | WTH25X07183681J |
| Issuing Body | Waltek Testing Group (Shenzhen) Co., Ltd. |
| Date of Issue | 2025-07-23 |
| Test Report Form No. | WTX_EN IEC 60335_1_2023B |
| Overall Result | Pass |
Product Information
The product evaluated in this report is the S6C inflator pump, manufactured and supplied by Guangdong Bestek Technology Co., Ltd. It is classified as a portable, indoor-use household appliance powered via DC connector under Class III equipment classification.
| Field | Detail |
|---|---|
| Product Name | Inflator Pump |
| Model No. | S6C |
| Trademark | — |
| Input Ratings | 5V 3A / 9V 3A / 12V 3A / 15V 3A / 20V 2.2A |
| Supply Connection | DC Connector |
| Equipment Class | Class III |
| Installation Type | Portable appliance, indoor use only |
| Water Ingress Protection | IPX0 |
| Manufacturer | Guangdong Bestek Technology Co., Ltd. |
| Manufacturer Address | No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China |
| Country of Origin | Made in China |
Note: LED lights incorporated in the product were not evaluated as part of this test report.
Key Details
The following table summarises the key test clauses evaluated under EN IEC 60335-1:2023+A11:2023, with results recorded per clause.
| Clause | Requirement / Test | Verdict |
|---|---|---|
| 5 | General Conditions for the Tests | Pass |
| 6 | Classification | Pass |
| 6.1 | Protection against electric shock — Class III | Pass |
| 6.2 | Protection against harmful ingress of water — IPX0 | N/A |
| 7 | Marking and Instructions | Pass |
| 7.1 | Rated voltage, current, manufacturer identification, model reference on marking label | Pass |
| 7.1 | Symbol IEC 60417-5172 (Class II) — not applicable to Class III | N/A |
| 7.1 | Appliance powered by rechargeable batteries recharged in the appliance | Pass |
Additional marking requirements noted in the report:
- Minimum CE mark height: 5 mm
- Minimum WEEE mark height: 7 mm
- The name and address of the EU Importer AND Manufacturer must be affixed on the product when placed on the EU market.
- Importer fields on the reference label are indicated as placeholder (XXX) pending final EU importer designation.
Standards & Compliance
The S6C inflator pump was tested against the following standards as part of its CE-LVD certification process:
| Standard | Title | Result |
|---|---|---|
| EN IEC 60335-1:2023+A11:2023 | Household and similar electrical appliances — Safety — Part 1: General requirements | Pass |
| EN 62233:2008 | Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure | Pass |
The product classification and applicable scope are as follows:
- Equipment Class: Class III (operates at Safety Extra-Low Voltage, SELV)
- Use Category: Household and indoor portable appliance
- Subcontracting: No test items were subcontracted to other laboratories; all testing was performed in-house at Waltek Testing Group (Shenzhen) Co., Ltd.
Validity & Certification Body
The test report was prepared and approved by Waltek Testing Group (Shenzhen) Co., Ltd., an accredited third-party testing laboratory. The report is valid under the condition that it bears the specific stamp of the test institute and the authorised signatures of the approver. Reproduction of the report is only permitted in full, with prior written permission from Waltek.
| Field | Detail |
|---|---|
| Testing Laboratory | Waltek Testing Group (Shenzhen) Co., Ltd. |
| Laboratory Address | 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70, Bao’an District, Shenzhen, Guangdong, China |
| Laboratory Website | http://www.waltek.com.cn |
| Tel | +86-755-33663308 |
| Fax | +86-755-33663309 |
| [email protected] | |
| Tested By | John Zhong / Project Engineer |
| Approved By | Harvid Wei / Manager |
| Date of Sample Receipt | 2025-07-14 |
| Test Period | 2025-07-14 to 2025-07-22 |
| Date of Issue | 2025-07-23 |
Frequently Asked Questions
- What does the CE-LVD certification mean for the S6C inflator pump?
-
CE-LVD (Low Voltage Directive) certification confirms that the S6C inflator pump meets the EU’s essential health and safety requirements for electrical equipment. It allows the product to be legally placed on the European market.
- Which standards was the S6C tested against?
-
The S6C was tested against EN IEC 60335-1:2023+A11:2023 (general household appliance safety) and EN 62233:2008 (electromagnetic field measurement for human exposure). Both tests returned a Pass result.
- What is the equipment class of the S6C, and why does it matter?
-
The S6C is classified as Class III equipment, meaning it operates at Safety Extra-Low Voltage (SELV) supplied via a DC connector. This classification means no mains-level insulation is required, but the power supply must itself be safety-certified before EU market placement.
- Are the LED lights in the S6C covered by this test report?
-
No. The test report explicitly states that LED lights incorporated into the S6C were not evaluated as part of this certification. A separate assessment may be required for those components depending on applicable directives.
Related Documents
For a complete compliance picture of the S6C inflator pump, the following related certification documents are recommended:
- CE-EMC Test Report — Electromagnetic Compatibility testing under EN 55014 series, required alongside LVD for full CE marking.
- CE-RED Certification — If the S6C incorporates any wireless or Bluetooth functionality, Radio Equipment Directive compliance is required.
- RoHS Compliance Report — Confirms restriction of hazardous substances per EU RoHS Directive 2011/65/EU.
- REACH SVHC Declaration — Substances of Very High Concern declaration under REACH Regulation (EC) No 1907/2006.
- UN38.3 Battery Transport Report — Required if the S6C contains a lithium-ion battery, covering transport safety testing per UN Manual of Tests and Criteria.
Document Pages