IEC 62133-2 Safety Test Report for ETENWOLF S0 Lithium-ion Battery Pack (WTH25D09245618B)

Document Overview

Document Overview This page presents the official safety test report issued by Waltek Testing Group Co., Ltd. under reference number WTH25D09245618B. The document is a full compliance test report conducted against the international standard IEC 62133-2:2017+AMD1:2021, which specifies safety requirements for portable sealed secondary lithium…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
International Transportation: CB / MSDS / UN38.3

Document Overview

This page presents the official safety test report issued by Waltek Testing Group Co., Ltd. under reference number WTH25D09245618B. The document is a full compliance test report conducted against the international standard IEC 62133-2:2017+AMD1:2021, which specifies safety requirements for portable sealed secondary lithium cells and batteries used in portable applications.

The report covers 25 pages including photo documentation attachments and was issued on 2025-11-13. Sample receipt date was 2025-09-15 and testing was conducted from 2025-09-15 to 2025-09-24. The test conclusion confirms that the submitted samples comply with all applicable requirements of the standard.

Field Details
Reference No. WTH25D09245618B
Document Type IEC 62133-2 Safety Test Report
Issuing Body Waltek Testing Group Co., Ltd.
Date of Issue 2025-11-13
Standard IEC 62133-2:2017+AMD1:2021
Test Result PASS — Compliant

Product Information

The battery pack tested is the internal power source of the ETENWOLF S0 portable bike pump, a compact and rechargeable inflation tool designed for cyclists and outdoor enthusiasts.

Field Details
Product Name Lithium-ion Battery Pack
Model No. 2S1P-1200
Trade Mark N/A
Classification Built-in and use in portable applications
Applicant Guangdong Bestek Technology Co., LTD
Manufacturer Guangdong Bestek Technology Co., LTD
Manufacturer Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R.China

The battery pack model 2S1P-1200 is a two-cell series, single-cell parallel configuration lithium-ion assembly built for use inside the ETENWOLF S0 portable pump. Its design is classified for built-in and portable application use, meaning it is permanently integrated into the host device and powers it during cordless operation.

Key Details

The test report covers a comprehensive battery of safety and abuse tests as required under IEC 62133-2:2017+AMD1:2021. Each test clause was executed at the Waltek Testing Group laboratory in Dongguan, Guangdong, China. All tests returned compliant results.

Clause Test Name Scope Result
7.2.1 Continuous charging at constant voltage Cells PASS
7.2.2 Case stress at high ambient temperature Battery PASS
7.3.1 External short-circuit Cell PASS
7.3.2 External short-circuit Battery PASS
7.3.3 Free fall Battery PASS
7.3.4 Thermal abuse Cells PASS
7.3.5 Crush Cells PASS
7.3.6 Over-charging of battery Battery PASS
7.3.7 Forced discharge Cells PASS
7.3.8.1 Vibration Battery PASS
7.3.8.2 Mechanical shock Battery PASS
7.3.9 Design evaluation – Forced internal short circuit Cells PASS

The product also fulfils the requirements of EN 62133-2:2017+AMD1:2021, confirming alignment with both the international IEC standard and its European harmonized equivalent, which is relevant for CE marking pathways.

Standards & Compliance

The ETENWOLF S0 battery pack was evaluated under the following standard:

Standard Full Title Applicability
IEC 62133-2:2017+AMD1:2021 Secondary cells and batteries containing alkaline or other non-acid electrolytes — Safety requirements for portable sealed secondary lithium cells, and for batteries made from them, for use in portable applications — Part 2: Lithium systems Primary test standard
EN 62133-2:2017+AMD1:2021 European harmonized equivalent of IEC 62133-2 EU market compliance

IEC 62133-2 is the globally recognized safety standard for lithium-ion cells and battery packs used in portable consumer devices. It mandates rigorous abuse testing — including short-circuit, overcharge, thermal, mechanical, and vibration tests — to ensure cells will not catch fire, explode, or leak under foreseeable misuse conditions. Compliance with this standard is a prerequisite for market access in many regions, including Europe (via CE marking under relevant directives) and other international markets.

The testing was performed entirely at the Waltek Testing Group Co., Ltd. facility, a nationally accredited testing and certification body operating under CNAS accreditation in China.

Validity & Certification Body

The test report WTH25D09245618B was prepared and approved by qualified engineers at Waltek Testing Group Co., Ltd. and is valid as a full compliance record for the battery model tested.

Field Details
Report Reference No. WTH25D09245618B
Date of Issue 2025-11-13
Sample Receipt Date 2025-09-15
Test Period 2025-09-15 to 2025-09-24
Total Pages 25 pages (including 3 pages of photo documentation)
Compiled By Jason Zhen / Project Engineer
Approved By Deval Qin / Designated Reviewer
Testing Laboratory Waltek Testing Group Co., Ltd.
Laboratory Address No. 77, Houjie Section, Guantai Road, Houjie Town, Dongguan City, Guangdong, China
Laboratory Tel +86-769-2267 6998
Laboratory Fax +86-769-2267 6828
Laboratory Website http://www.waltek.com.cn

This report is legally valid only in full and must bear the specific stamp of the test institute along with the signatures of both the compiler and approver. Partial reproduction is prohibited without prior written permission from Waltek Testing Group.

Frequently Asked Questions

What does IEC 62133-2 certification mean for the ETENWOLF S0?

IEC 62133-2:2017+AMD1:2021 is the internationally recognized safety standard for lithium-ion battery packs used in portable devices. For the ETENWOLF S0, passing this standard means its internal 2S1P-1200 battery pack has been independently verified to resist dangerous failures such as fire, explosion, or leakage under a comprehensive set of electrical, thermal, and mechanical abuse conditions.

Which tests were performed on the S0 battery pack, and did it pass all of them?

Yes. The ETENWOLF S0 battery pack was subjected to 12 distinct test procedures under IEC 62133-2, including continuous charging at constant voltage, external short-circuit (cell and battery level), free fall, thermal abuse, crush, overcharge, forced discharge, vibration, mechanical shock, and forced internal short-circuit design evaluation. All tests were passed.

Who conducted the IEC 62133-2 testing and is the laboratory accredited?

Testing was conducted by Waltek Testing Group Co., Ltd., located in Dongguan, Guangdong, China. Waltek is a CNAS-accredited third-party testing laboratory with broad international recognition. The report was compiled by Jason Zhen (Project Engineer) and approved by Deval Qin (Designated Reviewer), and the report reference number is WTH25D09245618B.

Is this IEC 62133-2 report also valid for European CE marking purposes?

The test report confirms compliance with both IEC 62133-2:2017+AMD1:2021 and its European harmonized equivalent EN 62133-2:2017+AMD1:2021. This dual compliance is a key input for CE marking under relevant EU directives applicable to portable battery-powered devices. However, CE marking itself requires a full Declaration of Conformity and may involve additional directives depending on the end product.

Related Documents

To support a complete compliance and market-access documentation package for the ETENWOLF S0 portable bike pump, the following related certification types are recommended:

  • UN 38.3 Transport Test Report — Mandatory for air and sea shipment of lithium-ion batteries. Covers altitude simulation, thermal cycling, vibration, shock, external short-circuit, impact, overcharge, and forced discharge for transport safety.
  • CE Declaration of Conformity — Required for sale in European Economic Area markets. Encompasses EMC Directive, Low Voltage Directive, and Battery Regulation compliance, supported by this IEC 62133-2 report.
  • FCC Part 15 / SDOC — Required for the United States market. Covers radio frequency emissions from the device’s electronic components including the battery management system.
  • RoHS Compliance Certificate — Confirms restriction of hazardous substances (lead, mercury, cadmium, etc.) in the battery cells and pack assembly, required for EU and many global markets.
  • REACH SVHC Declaration — Substances of Very High Concern screening report for the battery materials, required for EU importers and B2B supply chain disclosure.
  • KC Certification (Korea) — Required for sale in South Korea. The battery pack would require KC mark testing under relevant Korean electrical safety standards.
  • MSDS / Safety Data Sheet — Product safety data sheet for the lithium-ion battery pack, required for logistics, retail, and regulatory submission purposes globally.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22
Document Page 23
Document Page 24
Document Page 25