Drop Test Report – ETENWOLF X5 PRO Jump Starter with Air Compressor | GB/T 4857.5-1992

Document Overview

Document Overview This page presents the official free drop test report issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd. (http://www.hct-test.com), an accredited third-party testing laboratory located in Longgang District, Shenzhen, Guangdong, China. Field Detail Report Number WTH25H12334291P Document Type Free Drop Test Report (自由跌落测试)…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
Mechanical Reliability

Document Overview

This page presents the official free drop test report issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd. (http://www.hct-test.com), an accredited third-party testing laboratory located in Longgang District, Shenzhen, Guangdong, China.

Field Detail
Report Number WTH25H12334291P
Document Type Free Drop Test Report (自由跌落测试)
Test Standard GB/T 4857.5-1992
Date of Sample Receipt 2025/12/15
Testing Period 2025/12/17 to 2025/12/23
Date of Issue 2025/12/25
Test Report Form No. TRFCHEN-SE-001-V01
Total Pages 7

The report was prepared by Jack L (钟祺泷), inspected by Jeson Qi (戚照刚), and approved by Sem Huang (黄庆盛). It evaluates whether the product packaging and unit integrity survive a standardised free drop sequence simulating real-world handling and shipping conditions.

Product Information

The tested product is the X5 PRO Jump Starter with Air Compressor (多合一启充宝), a multi-function portable power device combining jump-start capability with an integrated air compressor.

Field Detail
Product Name Jump Starter with Air Compressor (多合一启充宝)
Model Number X5 PRO
Sample ID WTH25H12334291P_S-01
Applicant Guangdong Bestek Technology Co., LTD (广东贝仕达克科技有限公司)
Manufacturer Guangdong Bestek Technology Co., LTD (广东贝仕达克科技有限公司)
Manufacturer Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R.China

The X5 PRO is designed for automotive emergency use and outdoor activities, combining high-capacity battery cells with an onboard compressor. Robust drop performance is critical for a device intended for roadside and field deployment.

Key Details

Testing was performed using a Packaging Drop Testing Machine (Model: DT-325, Equipment No.: WTHP1300A1-001), calibrated on 2025/12/01 with calibration valid through 2026/11/30. All instruments are traceable to national or international standards.

Environmental Conditions

Parameter Value
Temperature 23.0 °C
Humidity 51.0 %RH

Drop Test Sequence — Drop Height: 1200 mm

Sequence Drop Position
1 Corner 2-3-5 (2-3-5 角)
2 Edge 3-5 (3-5 棱)
3 Edge 2-3 (2-3 棱)
4 Edge 2-5 (2-5 棱)
5 Face 5 (5 面)
6 Face 6 (6 面)
7 Face 3 (3 面)
8 Face 1 (1 面)
9 Face 2 (2 面)
10 Face 4 (4 面)

Test Results

Sample ID Sample Name Visual Inspection Result Functional Result
WTH25H12334291P_S-01 Jump Starter with Air Compressor No cracking or damage to packaging; no cracking or damage to product exterior Unit powers on and operates normally after all 10 drop sequences

Overall Conclusion: PASSED. The X5 PRO sample sustained no structural or functional damage across all 10 drop positions at a height of 1200 mm.

Standards & Compliance

The free drop test was conducted in strict accordance with the Chinese national packaging standard GB/T 4857.5-1992Packaging — Basic tests for transport packages — Part 5: Free drop test method. This standard specifies the test procedures for evaluating the ability of a packaged product to withstand free drops from a defined height onto a rigid surface, covering corner, edge, and face impact orientations.

Standard Scope Applicability
GB/T 4857.5-1992 Free drop test for transport packages Packaging integrity and product protection during handling and shipping

The evaluation rule applied states: if the measured outcome is equal to or below the defined limit (i.e., no cracking, damage, or functional failure), the test is passed, regardless of measurement uncertainty. If the outcome exceeds the limit, the test is not passed.

All calibration equipment used is traceable to national or international metrological standards. Further traceability information is available from Waltek HCT upon request.

Validity & Certification Body

This test report was issued on 2025/12/25 by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an independent testing laboratory. The report is valid only when bearing the approved signature of Sem Huang (黄庆盛) and the laboratory’s official seal.

Field Detail
Issuing Laboratory Waltek Testing Group HCT (Shenzhen) Co., Ltd.
Laboratory Address Building B, Tianji Industrial Park, 1/F, 2/F & 3/F, No.30-9, Laiyin Road, Xinsheng Community, Longgang Subdistrict, Longgang District, Shenzhen, Guangdong, China
Telephone +86-0755-84616666
Email [email protected]
Report Issue Date 2025/12/25
Calibration Equipment Valid Until 2026/11/30
Prepared By Jack L (钟祺泷)
Inspected By Jeson Qi (戚照刚)
Approved By Sem Huang (黄庆盛)

Important notes regarding report validity:

  • This report is invalid without the approving signatory and the laboratory’s special seal.
  • The report results apply solely to the specific sample tested (WTH25H12334291P_S-01).
  • Reports without the CMA logo are intended for internal reference purposes such as R&D, quality control, and scientific research, and do not constitute public certification.
  • Partial reproduction of this report is prohibited without written consent from Waltek HCT.
  • Any dispute regarding this report must be raised within 15 days of receipt.

Frequently Asked Questions

What does the drop test for the X5 PRO evaluate?
The drop test evaluates the ability of the X5 PRO packaging and product to withstand impacts from a height of 1200 mm across 10 different orientations — including corners, edges, and all six faces — as specified by GB/T 4857.5-1992. It confirms that the product arrives intact and fully functional after normal shipping and handling stresses.
What was the outcome of the drop test?
The X5 PRO passed all 10 drop sequences. After testing, the packaging showed no cracking or damage, the product exterior was undamaged, and the unit powered on and functioned normally. The result is documented in report WTH25H12334291P, issued on 2025/12/25.
Which laboratory conducted the drop test?
The test was conducted by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an independent third-party testing laboratory in Shenzhen, China. The laboratory’s equipment is calibrated and traceable to national and international standards.
Does this report serve as a public certification?
This report does not carry the CMA logo and is therefore intended for internal purposes such as product development, quality control, and research. It confirms drop test performance against GB/T 4857.5-1992 but does not constitute a regulatory certification for public market access on its own. For full regulatory compliance, refer to the product’s broader certification portfolio.

Related Documents

The drop test report is one component of the X5 PRO compliance documentation. The following related certification types are relevant for a Jump Starter with Air Compressor and are recommended as companion documents:

  • UN 38.3 Transportation Test Report — Required for lithium battery cells and packs in international shipping; covers altitude simulation, thermal testing, vibration, shock, external short circuit, impact, overcharge, and forced discharge.
  • CE Certification (LVD / EMC Directives) — Mandatory for sale in the European Economic Area; covers electrical safety and electromagnetic compatibility per applicable IEC standards.
  • FCC Declaration of Conformity — Required for sale in the United States; covers radio frequency emissions and electromagnetic interference.
  • KC Certification — Required for sale in South Korea; covers electrical safety and EMC.
  • RoHS Compliance Report — Confirms restriction of hazardous substances (lead, mercury, cadmium, etc.) per EU Directive 2011/65/EU and its amendment 2015/863/EU.
  • REACH Compliance Statement — Documents conformity with EU REACH regulations on substances of very high concern (SVHC).
  • Vibration Test Report — Complements the drop test by assessing resistance to sustained vibration during transport, typically per GB/T 4857.7 or ISTA protocols.
  • Battery Safety Test Report — Covers lithium battery safety per IEC 62133 or equivalent standards.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7