Document Overview
Key Findings The ETENWOLF HB2 Hair Dryer passed a 100 cm, 6-face single-arm drop test with minor bottom-cover scuffing but fully intact structure, normal power-on function, and normal charging — all within acceptance criteria. Product: HB2 Hair Dryer Drop Height: 100 cm Drop Faces: 6…
- Document type
- Test Report
- Prepared by
- Alex Newman
- Published
- Last reviewed
- Topics
- Mechanical Reliability
Key Findings
The ETENWOLF HB2 Hair Dryer passed a 100 cm, 6-face single-arm drop test with minor bottom-cover scuffing but fully intact structure, normal power-on function, and normal charging — all within acceptance criteria.
- Product: HB2 Hair Dryer
- Drop Height: 100 cm
- Drop Faces: 6 (one drop per face, 6 total)
- Sample Size: 3 pcs
- Environment: 22 °C / 55 % RH
- Structural Damage: None (minor bottom-cover surface mark only)
- Function After Drop: Power-on normal, charging normal
- Verdict: Pass
Test Overview
| Field | Detail |
|---|---|
| Test Type | Drop Test (Mechanical Reliability) |
| Report No. | 20250419001.0 |
| Page | 1.0 |
| Date | 2025-04-19 |
| Product Name | HB2 Hair Dryer |
| Manufacturer | BTK |
| Sample Quantity | 3 PCS |
| Surface Treatment | — |
| Test Reason | New Product |
| Test Purpose | Evaluate the product’s resistance to drop impact and assess its reliability |
| Laboratory Temperature | 22 °C |
| Laboratory Humidity | 55 % RH |
Test Equipment & Setup
| Parameter | Value |
|---|---|
| Instrument | Single-arm drop testing machine |
| Drop Height | 100 cm |
| Number of Drop Faces | 6 faces (6 drops total) |
| Sample Weight | Not recorded |
| Test Class | Not specified |
Test Procedure
- Pre-test inspection: Visually inspect all 3 samples for pre-existing damage; record appearance baseline and verify power-on and charging function are normal.
- Environment conditioning: Confirm laboratory temperature is 22 °C and relative humidity is 55 % RH before testing.
- Mounting: Load the sample into the single-arm drop testing machine. Set drop height to 100 cm.
- Drop sequence: Execute one drop for each of the 6 faces (Face 1 through Face 6), for a total of 6 drops per sample unit.
- Post-drop visual inspection: Immediately after each drop, inspect the sample for cracks, deformation, fractures, or any structural damage to housing components.
- Functional verification: After all 6 drops, power on the device and verify normal operation; connect charger and verify normal charging.
- Acceptance criteria: Structural components must show no damage, cracking, or deformation. Power-on function and charging must operate normally.
Test Data & Results
| Stage | Observation |
|---|---|
| Before drop | Samples inspected prior to testing — appearance normal |
| Drop sequence (Faces 1–6) | 6 drops executed: Face 1, Face 2, Face 3, Face 4, Face 5, Face 6 |
| Post-drop — Appearance | No structural breakage; minor surface damage to bottom cover |
| Post-drop — Power-on function | Normal |
| Post-drop — Charging | Normal |
Test result summary (as recorded): After a 100 cm single-arm drop test, the HB2 sample showed no breakage to its exterior; the bottom cover sustained minor surface damage. Power-on function was normal and charging was normal.
Conclusion
| Item | Detail |
|---|---|
| Result | Pass |
| Standard / Condition | 100 cm, 6-face single-arm drop; 22 °C / 55 % RH |
| Acceptance Criterion | No structural damage, cracking, or deformation; functions normal after drop |
| Samples Tested | 3 PCS HB2 Hair Dryer |
| Verdict | ■ Pass |
Document Information
| Role | Name (Pinyin) |
|---|---|
| Approval (核准) | Mai Shaoqiang |
| Review (审查) | Zhang Ronggui |
| Tester (测试) | Li Guanghua |
| Form Number | BTK-R-Q-087A/1 |
Frequently Asked Questions
What drop height was used in the ETENWOLF HB2 hair dryer drop test?
The HB2 hair dryer was tested at a drop height of 100 cm using a single-arm drop testing machine, with one drop performed on each of 6 faces for a total of 6 drops.
Did the HB2 hair dryer pass the drop test?
Yes. The HB2 passed with a verdict of Pass. After 6 drops from 100 cm, the unit showed only minor surface marking on the bottom cover, with no structural damage, cracking, or deformation, and both power-on and charging functions remained fully normal.
What acceptance criteria were applied to the HB2 drop test?
The acceptance criteria required that all structural components show no damage, cracking, or deformation after the drops, and that the device power on and charge normally once testing was complete.
Who approved the HB2 drop test report?
The report was approved by Mai Shaoqiang, reviewed by Zhang Ronggui, and the tester was Li Guanghua. The form number is BTK-R-Q-087A/1, dated 2025-04-19.