Document Overview
Document Overview This page presents the CE Electromagnetic Compatibility (EMC) test report issued for the ETENWOLF C2 Wireless Portable Tire Pump. The report was prepared by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited electromagnetic compatibility testing laboratory located in Longgang District, Shenzhen, Guangdong,…
- Document type
- Certification Report
- Prepared by
- Michelle Torres
- Published
- Last reviewed
- Topics
- European Union: CE / RoHS / REACH / WEEE
Document Overview
This page presents the CE Electromagnetic Compatibility (EMC) test report issued for the ETENWOLF C2 Wireless Portable Tire Pump. The report was prepared by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited electromagnetic compatibility testing laboratory located in Longgang District, Shenzhen, Guangdong, China.
| Field | Detail |
|---|---|
| Reference Number | WTH25H09239214E |
| Document Type | CE-EMC Test Report |
| Test Report Form No. | TRF EN IEC 55014-1: 2021-EMC-001-V01 |
| Internal Form Reference | HCT/RF-23-21 |
| Date of Sample Receipt | 2025-09-05 |
| Date of Testing | 2025-09-08 to 2025-09-10 |
| Date of Issue | 2025-09-15 |
| Overall Test Result | Pass |
The scope of this report covers electromagnetic emissions testing — specifically conducted disturbances at mains terminals, disturbance power in the frequency range, and radiated disturbances — confirming the product’s compliance with applicable European EMC Directives for CE marking purposes.
Product Information
The Equipment Under Test (EUT) evaluated in report WTH25H09239214E is the ETENWOLF C2 Wireless Portable Tire Pump, a battery-powered cordless inflation tool designed for inflating vehicle tires and other inflatables without requiring a mains power connection during operation.
| Field | Detail |
|---|---|
| Product Name | Wireless Portable Tire Pump |
| Model Number | C2 |
| Brand | ETENWOLF |
| Applicant | Guangdong Bestek Technology Co., Ltd. |
| Manufacturer | Guangdong Bestek Technology Co., Ltd. |
| Manufacturer Address | No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China |
As a portable, motor-driven electrical appliance, the C2 falls under the product category addressed by the household and similar electrical appliances EMC standard series, requiring assessment of both conducted and radiated electromagnetic emissions to ensure it does not interfere with other equipment operating in its environment.
Key Details
The test report WTH25H09239214E covers a comprehensive set of EMC emission measurements conducted across three primary test categories. All measurements were performed with the EUT in its intended operational mode simulating active tire inflation. The following table summarises the test areas covered and their outcomes.
| Test Category | Section | Standard Applied | Result |
|---|---|---|---|
| Conducted Disturbance at Mains Terminals | Section 3 | EN IEC 55014-1: 2021 | Pass |
| Disturbance Power in the Frequency Range | Section 4 | EN IEC 55014-1: 2021 | Pass |
| Radiated Disturbances | Section 5 | EN IEC 55014-1: 2021 | Pass |
| Harmonics Current Emissions | Referenced | EN IEC 61000-3-2: 2019+A1:2021 | Pass |
| Voltage Fluctuations and Flicker | Referenced | EN 61000-3-3: 2013+A2:2021 | Pass |
The test configuration included justification documentation, EUT exercise procedures, equipment modification records, basic system configuration descriptions, general descriptions of test auxiliaries, and application of the laboratory’s decision rule — all detailed across sections 2.1 through 2.6 of the full 51-page report. Measurement uncertainty budgets were documented for each test category in accordance with laboratory quality requirements.
Tests were carried out between 2025-09-08 and 2025-09-10 at the HCT Shenzhen facility. The report was prepared by Snow Zeng and approved by Tony Wu of Waltek Testing Group HCT (Shenzhen) Co., Ltd.
Standards & Compliance
The ETENWOLF C2 was evaluated against the following European harmonised standards. Compliance with these standards supports the CE marking declaration for the EMC Directive 2014/30/EU.
| Standard | Title | Scope |
|---|---|---|
| EN IEC 55014-1: 2021 | Electromagnetic Compatibility — Requirements for Household Appliances, Electric Tools and Similar Apparatus — Part 1: Emission | Conducted and radiated emission limits for motor-operated and switching devices |
| EN IEC 55014-2: 2021 | Electromagnetic Compatibility — Requirements for Household Appliances, Electric Tools and Similar Apparatus — Part 2: Immunity | Immunity requirements for the same product category |
| EN IEC 61000-3-2: 2019+A1:2021 | Electromagnetic Compatibility — Limits for Harmonic Current Emissions | Harmonic current emissions for equipment with input current up to and including 16 A per phase |
| EN 61000-3-3: 2013+A2:2021 | Electromagnetic Compatibility — Limitation of Voltage Changes, Voltage Fluctuations and Flicker | Voltage fluctuation and flicker limits for equipment with rated current up to and including 16 A |
The test report form used was TRF EN IEC 55014-1: 2021-EMC-001-V01, which is the standardised reporting template aligned with the EN IEC 55014-1: 2021 test methodology. The laboratory’s decision rule for determining pass/fail against measurement uncertainty was applied as documented in Section 2.6 of the report.
Validity & Certification Body
The test report WTH25H09239214E was issued on 2025-09-15 by Waltek Testing Group HCT (Shenzhen) Co., Ltd. Details of the issuing laboratory are provided below.
| Field | Detail |
|---|---|
| Laboratory Name | Waltek Testing Group HCT (Shenzhen) Co., Ltd. |
| Laboratory Address | Building B, Tianji Industrial Park, 1/F. & 2/F. & 3/F., No.30-9, Laiyin Road, Xinsheng Community, Longgang Subdistrict, Longgang District, Shenzhen, Guangdong, China |
| Website | http://www.hct-test.com |
| Service Telephone | 400-0066-989 |
| Service Email | [email protected] |
| Prepared By | Snow Zeng |
| Approved By | Tony Wu |
| Report Issue Date | 2025-09-15 |
| Total Report Pages | 51 |
This test report supports CE marking under the CE EMC Directive 2014/30/EU. The report is valid for the specific product model, configuration, and manufacturer identified herein. Any changes to the product design, circuitry, or construction may require re-evaluation. Validity is contingent on the product remaining unchanged from the tested sample configuration.
Frequently Asked Questions
- What does the CE-EMC test report WTH25H09239214E confirm about the ETENWOLF C2?
-
Report WTH25H09239214E confirms that the ETENWOLF C2 Wireless Portable Tire Pump passed all electromagnetic compatibility emission tests required for CE marking under the EMC Directive 2014/30/EU. Tests covered conducted disturbances at mains terminals, disturbance power, radiated disturbances, harmonic current emissions, and voltage fluctuation/flicker — all evaluated against the applicable EN IEC 55014-1: 2021, EN IEC 55014-2: 2021, EN IEC 61000-3-2: 2019+A1:2021, and EN 61000-3-3: 2013+A2:2021 standards.
- Which standards were used to test the ETENWOLF C2 for CE-EMC compliance?
-
The C2 was tested against four harmonised European standards: EN IEC 55014-1: 2021 and EN IEC 55014-2: 2021 (emission and immunity requirements for household appliances and electric tools), EN IEC 61000-3-2: 2019+A1:2021 (harmonic current emissions), and EN 61000-3-3: 2013+A2:2021 (voltage fluctuations and flicker). These standards are harmonised under the EU EMC Directive 2014/30/EU.
- Who conducted the CE-EMC testing for the ETENWOLF C2?
-
The testing was conducted by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an EMC testing laboratory based in Longgang District, Shenzhen, China. The report was prepared by Snow Zeng and approved by Tony Wu. Testing took place from 2025-09-08 to 2025-09-10, and the report was issued on 2025-09-15.
- Does the CE-EMC pass mean the ETENWOLF C2 is safe to sell in Europe?
-
A passing CE-EMC test report is a key component of the CE marking process, demonstrating that the C2 meets electromagnetic compatibility requirements for the European market. However, full CE marking may also require compliance with other applicable directives (such as the Low Voltage Directive or Machinery Directive depending on the product classification) and a complete Declaration of Conformity from the manufacturer. The EMC report alone covers the electromagnetic emissions and immunity aspect.
Related Documents
The CE-EMC test report is one component of the full compliance documentation for the ETENWOLF C2 Wireless Portable Tire Pump. The following related certification and test document types are typically associated with this product category and are relevant for market access across different regions.
- CE-LVD Test Report — Low Voltage Directive safety testing (EN 62368-1 or EN 60335 series) required alongside EMC for full CE marking of electrically powered portable tools.
- UN 38.3 Battery Test Report — UN 38.3 transport safety certification for the lithium-ion battery cells used in the C2, required for air freight and international shipping compliance.
- FCC ID / FCC Part 15B Report — FCC electromagnetic compatibility certification required for sale in the United States market, covering unintentional radiators.
- KC Certification (KС EMC) — KC mark electromagnetic compatibility certification required for the South Korean market under the Radio Waves Act.
- RoHS Compliance Report — RoHS Directive 2011/65/EU compliance documentation confirming restriction of hazardous substances in the product.
- REACH SVHC Declaration — REACH regulation substance declaration confirming no substances of very high concern exceed threshold limits in the C2 and its components.
- CE Declaration of Conformity (DoC) — The manufacturer’s formal declaration combining all applicable CE directive results, signed by an authorised representative, required to affix the CE mark to the product.
Document Pages