Document Overview
Key Findings ETENWOLF EV3 Tire Inflator completed a continuous temperature-rise logging run. The highest recorded channel value was 55.23 °C (Channel 1). The page presents engineering statistics and representative checkpoints instead of reproducing every acquisition row. Source workbook: EV3充气泵-温升报告-2025.4.7.xls Recorded scans: 185 Monitored numeric channels:…
- Document type
- Test Report
- Prepared by
- Daniel Wright
- Published
- Last reviewed
- Topics
- Environmental Testing
Key Findings
ETENWOLF EV3 Tire Inflator completed a continuous temperature-rise logging run. The highest recorded channel value was 55.23 °C (Channel 1). The page presents engineering statistics and representative checkpoints instead of reproducing every acquisition row.
- Source workbook: EV3充气泵-温升报告-2025.4.7.xls
- Recorded scans: 185
- Monitored numeric channels: 7
- Source sheet: 温升数据
Test Overview
| Field | Value |
|---|---|
| Product | ETENWOLF EV3 Tire Inflator |
| Test type | Continuous temperature-rise data acquisition |
| Instrument | Keysight DAQ970A (as identified in the source workbook) |
| Data treatment | Channel statistics plus evenly spaced representative scans |
| Raw-data authority | Original Excel workbook |
Test Method
- Operate the product under the load and setup defined by the companion test-report sheet.
- Log the ambient reference and component temperature channels continuously.
- Review start, peak, end and stabilization behavior for every numeric channel.
- Retain the workbook as the authoritative interval-by-interval record.
Test Data & Results
Channel Summary
| Channel | Start °C | Peak °C | Peak scan | End °C |
|---|---|---|---|---|
| Channel 1 | 28.39 | 55.23 | 185 | 55.23 |
| Channel 2 | 28.58 | 50.09 | 185 | 50.09 |
| Channel 3 | 27.85 | 49.28 | 185 | 49.28 |
| Channel 4 | 27.78 | 46.50 | 126 | 46.11 |
| Channel 5 | 28.26 | 52.91 | 185 | 52.91 |
| Channel 6 | 27.98 | 44.96 | 185 | 44.96 |
| Channel 7 | 26.74 | 27.42 | 88 | 26.87 |
Representative Checkpoints
| Scan | Channel 1 | Channel 2 | Channel 3 | Channel 4 | Channel 5 | Channel 6 | Channel 7 |
|---|---|---|---|---|---|---|---|
| 1 | 28.39 | 28.58 | 27.85 | 27.78 | 28.26 | 27.98 | 26.74 |
| 47 | 38.39 | 40.39 | 36.40 | 38.37 | 38.23 | 38.64 | 26.86 |
| 93 | 44.70 | 44.72 | 41.99 | 42.85 | 45.13 | 42.81 | 27.25 |
| 139 | 49.96 | 47.63 | 46.45 | 45.70 | 49.05 | 43.85 | 26.76 |
| 185 | 55.23 | 50.09 | 49.28 | 46.11 | 52.91 | 44.96 | 26.87 |
Data coverage note: The original sheet contains 185 acquisition rows. This web article intentionally condenses the series to channel-level statistics and representative checkpoints; no unreported value is inferred or fabricated.
Conclusion
This article reports the measured thermal profile without introducing a pass/fail threshold that is not present in the source data. Any formal compliance decision must be taken from the signed report sheet and its stated acceptance criteria.
Frequently Asked Questions
Why is the complete scan log not displayed?
The raw log is too long for a usable web page. Start, peak and end values are retained for every numeric channel, with representative checkpoints showing the progression.
Was any missing measurement estimated?
No. Blank or non-numeric source cells are shown as unavailable and are never interpolated.
Related Documents
- Companion test-report sheet in EV3充气泵-温升报告-2025.4.7.xls
- Original acquisition worksheet: 温升数据
- Product information for ETENWOLF EV3 Tire Inflator