ETENWOLF S7 Tire Inflator Discharge Duration Test Report (35 PSI Load, 3-Sample)

Document Overview

Key Findings All three S7 tire inflator units completed full-battery discharge cycles within a consistent range of 39–43 minutes under a sustained 35 ± 2 PSI pressure load, demonstrating stable battery endurance across repeated runs. Test type: Battery discharge duration Load condition: 35 ± 2…

Document type
Test Report
Prepared by
Daniel Wright
Published
Last reviewed
Topics
Battery Testing

Key Findings

All three S7 tire inflator units completed full-battery discharge cycles within a consistent range of 39–43 minutes under a sustained 35 ± 2 PSI pressure load, demonstrating stable battery endurance across repeated runs.

  • Test type: Battery discharge duration
  • Load condition: 35 ± 2 PSI continuous pressure
  • Samples tested: 3 units (1#, 2#, 3#), 3 runs each
  • Discharge time range: 39 – 43 minutes
  • Unit 1# average: 40.3 min | Unit 2# average: 42.0 min | Unit 3# average: 40.7 min
  • Overall verdict: Consistent battery performance across all units and runs

Test Overview

Field Detail
Test Type Battery Discharge Duration
Sheet Name 放电时间 (Discharge Duration)
Source File S7充气泵-放电时间测试数据20250312.xlsx
Date (file) 2025-03-12
Product ETENWOLF Vortex S7 Tire Inflator
Model S7
Product Line Inflation Tools
Category Air Pump / Compressor Products (0气泵类项目)
Number of Samples 3 units (1#, 2#, 3#)
Runs per Sample 3
Total Data Points 9
Load Condition 35 ± 2 PSI, continuous discharge
Starting State Battery fully charged before each test

Test Equipment & Setup

Parameter Value
Test Subject ETENWOLF S7 Tire Inflator (bare unit)
Charge State at Start Fully charged (100%)
Pressure Load 35 ± 2 PSI
Discharge Mode Continuous operation at set pressure
Measurement Parameter Elapsed time from start to battery depletion (minutes)
Timing Unit Minutes
Sample Count 3 units
Repetitions per Unit 3 runs

Test Procedure

  1. Pre-test: Fully charge each S7 unit until the charging indicator confirms 100% capacity.
  2. Setup: Connect the unit to a pressure load fixture calibrated to 35 ± 2 PSI.
  3. Start timing: Activate the inflator and begin recording elapsed time in minutes.
  4. Continuous discharge: Allow the unit to operate continuously at the set pressure load without interruption.
  5. End point: Stop the timer when the battery is fully depleted and the unit ceases operation.
  6. Record: Log the elapsed discharge time (minutes) for the completed run.
  7. Repeat: Recharge the unit fully and repeat steps 2–6 for a total of 3 runs per unit.
  8. Repeat for all samples: Perform the full 3-run sequence on units 2# and 3#.
  9. Post-test: Compile all 9 recorded times and review for consistency across runs and units.

Acceptance criteria: Results are considered consistent when discharge times across all runs and units fall within a narrow, repeatable range with no outliers indicating premature battery failure.

Test Data & Results

Unit No. Run Discharge Time (min) Unit No. Run Discharge Time (min) Unit No. Run Discharge Time (min)
1# 1 41 2# 1 43 3# 1 40
1# 2 39 2# 2 41 3# 2 41
1# 3 41 2# 3 42 3# 3 41

Observations:

  • Unit 1# recorded times of 41, 39, and 41 minutes — average 40.3 min. The single 39-minute run is within 1 minute of the other two, indicating normal variation.
  • Unit 2# recorded times of 43, 41, and 42 minutes — average 42.0 min. This unit consistently performed at the upper end of the range.
  • Unit 3# recorded times of 40, 41, and 41 minutes — average 40.7 min. Highly consistent across all three runs.
  • Overall range across all 9 data points: 39 – 43 minutes. Spread of 4 minutes across 9 runs is indicative of stable, repeatable battery capacity.

Conclusion

Item Detail
Test Battery Discharge Duration at 35 ± 2 PSI
Load Condition 35 ± 2 PSI continuous pressure
Starting Condition Fully charged battery
Samples 3 units × 3 runs = 9 data points
Discharge Time Range 39 – 43 minutes
Unit 1# Average 40.3 min
Unit 2# Average 42.0 min
Unit 3# Average 40.7 min
Overall Average 41.0 min
Verdict PASS — All units demonstrated consistent and repeatable battery discharge performance

Document Information

Role Name Detail
Author / Tester Daniel Wright ETENWOLF Test Lab
Source Document S7充气泵-放电时间测试数据20250312.xlsx
Sheet 放电时间 (Sheet Index 2 of 2)
Term ID 93
Author ID 3
Publication Date 2026-07-10

Frequently Asked Questions

How long does the ETENWOLF S7 tire inflator battery last on a single charge?

Under a continuous 35 ± 2 PSI pressure load, the S7 ran for between 39 and 43 minutes per charge across 9 test runs on 3 separate units, with an overall average of approximately 41 minutes.

What pressure load was used in the S7 discharge duration test?

The test applied a sustained pressure load of 35 ± 2 PSI throughout each discharge cycle, simulating a representative continuous inflation workload.

Were multiple S7 units tested for battery life consistency?

Yes. Three individual units (1#, 2#, 3#) were each tested across three full discharge runs. All nine results fell within a 39–43 minute window, confirming consistent battery performance across production samples.

What does the S7 discharge duration test tell us about battery reliability?

The narrow 4-minute spread across all 9 runs indicates that S7 battery capacity is stable and repeatable. No unit showed premature shutdown or significant degradation across repeated cycles, supporting confidence in the battery’s real-world endurance.