ETENWOLF S0 Portable Bike Pump Temperature Rise Test Report (185 Scans, Dual-Unit)

Document Overview

Key Findings The ETENWOLF S0 portable bike pump completed a full 185-scan temperature-rise logging session, with both test units reaching thermal near-equilibrium; peak measured temperatures of 82.31 °C (S0-9# cylinder) and 82.25 °C (S0-2# nozzle connection) were recorded at the end of the run, while…

Document type
Certification Report
Prepared by
Daniel Wright
Published
Last reviewed
Topics
Environmental Testing

Key Findings

The ETENWOLF S0 portable bike pump completed a full 185-scan temperature-rise logging session, with both test units reaching thermal near-equilibrium; peak measured temperatures of 82.31 °C (S0-9# cylinder) and 82.25 °C (S0-2# nozzle connection) were recorded at the end of the run, while ambient laboratory temperature remained stable between approximately 26.1 °C and 26.8 °C throughout the entire test.

  • Test type: Temperature-rise (温升) environmental test
  • Product: ETENWOLF S0 Portable Bike Pump
  • Units under test: S0-2# and S0-9# (two samples)
  • Data logger: Keysight DAQ970A, S/N MY58035717
  • Total scans: 185 (scan interval ≈ 5 seconds)
  • Ambient temperature range: 26.18 °C – 26.78 °C
  • Peak temperature – S0-2# nozzle connection: 82.25 °C (scan 183)
  • Peak temperature – S0-9# cylinder: 82.30 °C (scan 184)
  • Monitored points per unit: battery, cylinder, nozzle connection, hose tail, hose head (5 channels each)
  • Thermal stabilisation observed: both units approached steady state after approximately scan 130

Test Overview

Parameter Detail
Test Type Environmental Testing – Temperature Rise (温升变化)
Standard / Method Internal temperature-rise monitoring protocol
Source File S0 充气泵-温升报告-2025.8.5.xls
Sheet Name 温升变化数据 (Temperature Rise Change Data)
Test Date 2025-08-05
Product ETENWOLF S0 Portable Bike Pump
Manufacturer ETENWOLF
Product Line Inflation Tools
Samples 2 units: S0-2# and S0-9#
Test Environment Indoor laboratory; ambient 26.1 °C – 26.8 °C (recorded continuously)
Total Data Rows 185 measurement scans + 1 peak-summary row

Test Equipment & Setup

Item Detail
Instrument Keysight DAQ970A Data Acquisition System
VISA Address USB0::0x2A8D::0x5101::MY58035717::0::INSTR
Serial Number MY58035717
Firmware Version A.02.03-01.00-02.01-00.02-02.00-03-02
Logging Start Time (Excel serial) 45873.8551912037
Logging Stop Time (Excel serial) 45873.86583974537
Approximate Elapsed Time ~15.3 minutes (185 scans)
Scan Interval ≈ 5 seconds
Measurement Channels – S0-2# Battery, Cylinder, Nozzle Connection, Hose Tail, Hose Head
Measurement Channels – S0-9# Battery, Cylinder, Nozzle Connection, Hose Tail, Hose Head
Reference Channel Laboratory Ambient Temperature
Total Active Channels 11 (1 ambient + 5 per unit × 2 units)

Test Procedure

  1. Pre-test preparation: Install the DAQ970A data acquisition system and connect thermocouple probes to all five measurement points on each sample unit (battery body, cylinder, nozzle connection, hose tail, hose head) plus one ambient reference probe. Verify VISA address and firmware version. Allow equipment to warm up and confirm ambient stability.
  2. Initial baseline scan: Record scan 1 with the pump at rest to establish baseline temperatures across all channels (all channels expected near ambient ≈ 26–27 °C).
  3. Pump activation: Start the S0 pump units and begin continuous inflation operation at rated conditions.
  4. Continuous data logging: The DAQ970A automatically records all 11 channels at approximately 5-second intervals. Do not interrupt operation. Monitor for any anomalies.
  5. Thermal run: Continue logging until temperature readings plateau and indicate thermal steady-state (target minimum 180 scans or visible stabilisation of all channels).
  6. Post-test stop: After scan 185, stop pump operation. The DAQ970A logs the stop event (“数据记录已停止” – data logging stopped). Record final readings.
  7. Peak temperature extraction: The system automatically extracts the maximum temperature recorded for each channel across the entire run (reported in the “最高温度” / Maximum Temperature row).
  8. Acceptance criteria: All monitored surface temperatures should remain within safe operational limits throughout continuous operation. Thermal plateau must be demonstrated. No thermal runaway or uncontrolled temperature rise is acceptable.

Test Data & Results

Maximum Temperatures Recorded

Channel Unit Max Temperature (°C)
Laboratory Ambient 26.777
Battery S0-2# 46.739
Cylinder S0-2# 71.056
Nozzle Connection S0-2# 82.246
Hose Tail S0-2# 55.965
Hose Head S0-2# 49.191
Battery S0-9# 47.529
Cylinder S0-9# 77.603
Nozzle Connection S0-9# 82.303
Hose Tail S0-9# 60.175
Hose Head S0-9# 51.773

Full Scan-by-Scan Temperature Data (All 185 Scans)

Scan Time (Excel Serial) Scan No. Ambient (°C) S0-2# S0-9#
Battery (°C) Cylinder (°C) Nozzle Conn. (°C) Hose Tail (°C) Hose Head (°C) Battery (°C) Cylinder (°C) Nozzle Conn. (°C) Hose Tail (°C) Hose Head (°C)
45873.85519167824 1 26.3347 26.7730 26.7892 27.6789 27.0238 27.0115 26.9604 26.9108 26.9127 26.7283 27.2870
45873.85524946759 2 26.4655 26.7707 26.7858 30.3790 27.2754 26.9070 26.9629 26.9122 26.8857 26.7339 27.2532
45873.855307337966 3 26.5410 26.7715 26.7961 32.4434 27.5361 26.8359 26.9427 26.9067 26.9367 26.7297 27.2670
45873.855365208336 4 26.4492 26.7672 26.7908 34.4841 27.8010 26.7992 26.9425 26.9148 26.9176 26.7180 27.2511
45873.855423078705 5 26.5487 26.7605 26.7738 34.2581 28.0820 26.7789 26.9401 26.9242 26.9214 26.7310 27.0226
45873.855480949074 6 26.5754 26.7636 26.7939 32.8919 28.3255 26.7292 26.9526 26.9259 26.9061 26.7837 27.0217
45873.85553881944 7 26.5955 26.7909 26.8250 32.3671 28.5412 26.8057 26.9675 27.1326 27.1839 26.8627 27.1201
45873.85559668981 8 26.6361 26.9651 27.6151 32.1498 28.8045 26.9033 27.1023 28.3012 28.4593 26.9635 27.2192
45873.85565456018 9 26.7732 27.1409 28.9215 32.0709 29.0145 27.0730 27.2750 29.6186 29.7047 27.3164 27.4013
45873.85571243056 10 26.5999 27.3805 30.5537 31.9198 29.2543 27.1689 27.5170 30.9842 30.9927 27.7355 27.6407
45873.85577030093 11 26.6772 27.6927 32.4977 36.6775 29.4973 27.3758 27.6689 32.2404 32.1600 28.2045 27.8944
45873.8558281713 12 26.4247 28.0102 34.5479 38.4392 29.7400 27.6817 27.8305 33.4533 33.2856 28.6377 28.1060
45873.85588604167 13 26.3391 28.3699 36.6239 40.0879 29.9709 28.1931 28.0358 34.7592 34.6503 29.2268 28.3725
45873.855943912036 14 26.3044 28.6773 38.6452 41.6174 30.2139 28.6703 28.2472 36.3372 36.6990 29.8348 28.5929
45873.856001782406 15 26.3174 28.9793 40.5325 42.9806 30.4591 29.1445 28.4839 38.1418 38.8548 30.6227 28.9030
45873.856059652775 16 26.3031 29.2636 42.3290 44.2802 30.6915 29.7051 28.6331 39.9496 40.7914 31.4846 29.2179
45873.85611752315 17 26.3221 29.5413 43.9634 45.4889 30.8962 30.2562 28.8948 41.5976 42.5436 32.4486 29.4973
45873.85617539352 18 26.3537 29.8651 45.5543 46.6583 31.1149 30.8291 29.2031 43.2306 44.2414 33.3493 29.7742
45873.85623326389 19 26.4817 30.1434 46.9762 47.7561 31.3182 31.4877 29.3844 44.6822 46.2778 34.1210 30.0857
45873.85629113426 20 26.5457 30.4600 48.3492 48.8198 31.5485 32.0180 29.6012 46.1632 48.2446 34.8719 30.3794
45873.85634900463 21 26.6085 30.7460 49.6416 49.8300 31.7439 32.5333 29.8896 47.5087 49.6341 35.6281 30.7237
45873.856406875 22 26.6641 31.0839 50.8825 50.8177 31.9469 32.9612 30.0995 48.7776 50.8638 36.3413 31.0341
45873.85646474537 23 26.5755 31.3602 51.9798 51.7530 32.1702 33.4175 30.2989 49.9787 52.0518 37.1310 31.3308
45873.856522615744 24 26.3973 31.5357 53.0738 52.6662 32.3501 33.7819 30.5264 51.0637 53.1040 37.8204 31.5992
45873.856580486114 25 26.4053 31.7527 54.1090 53.5650 32.5659 33.9040 30.6596 52.1913 54.0234 38.3541 31.8844
45873.85663835648 26 26.5270 32.0496 55.1070 54.3999 32.7161 34.3087 31.0045 53.2494 55.1766 38.9160 32.1400
45873.85669622685 27 26.6247 32.2367 55.9500 55.2148 32.8748 34.6709 31.3300 54.1909 56.1816 39.4494 32.5239
45873.85675409722 28 26.6208 32.5248 56.8275 56.0003 33.0913 34.4255 31.7563 55.1217 57.2374 40.2855 32.7936
45873.85681196759 29 26.6436 32.6579 57.6201 56.7775 33.2898 34.6962 31.9309 55.6930 57.9786 40.7759 33.1030
45873.85686983796 30 26.6251 32.8358 58.3192 57.5437 33.4921 34.6375 32.2547 56.4078 58.8395 41.5614 33.3487
45873.85692770833 31 26.5727 33.0094 59.0963 58.2921 33.7092 35.0335 32.4497 56.9894 59.5505 41.9747 33.5828
45873.85698557871 32 26.7775 33.1222 59.7605 58.9936 33.9177 35.5516 32.6069 57.5900 60.2342 42.5113 33.8796
45873.857043449076 33 26.6946 33.2481 60.3570 59.6799 34.1200 35.9660 32.6885 58.2445 60.8965 42.9886 34.1484
45873.857101319445 34 26.4717 33.3855 60.9436 60.4094 34.2887 36.2977 32.8641 58.8578 61.4598 43.3992 34.4152
45873.857159189814 35 26.3855 33.5250 61.5188 61.0245 34.4642 36.4862 32.9813 59.4436 61.9241 43.7615 34.6396
45873.857217060184 36 26.4307 33.5912 62.0012 61.6503 34.6432 36.7402 33.0264 60.0466 62.4192 44.0782 34.8989
45873.85727493055 37 26.4683 33.7824 62.4543 62.2616 34.7963 36.9414 33.2425 60.6021 63.0511 44.5976 35.1514
45873.85733280092 38 26.5633 33.9323 62.9586 62.8679 35.0083 37.2362 33.3647 61.0705 63.6020 45.0335 35.3819
45873.8573906713 39 26.5941 34.0600 61.8889 63.4486 35.1427 37.5240 33.5722 61.6270 64.1977 45.3606 35.6475
45873.85744854167 40 26.4991 34.2002 63.3032 64.0081 35.3367 37.7037 33.7773 62.0424 64.7138 45.8039 35.8121
45873.85750641204 41 26.5425 34.3410 63.2032 64.5498 35.5130 37.8203 33.8221 62.5055 65.0909 46.0555 36.0407
45873.85756428241 42 26.5514 34.4791 63.5406 65.0660 35.7029 38.1903 33.9708 62.9382 65.5937 46.3389 36.2697
45873.85762215278 43 26.5359 34.6035 62.6805 65.5624 35.8531 38.2856 34.0380 63.3686 66.1074 46.6138 36.5171
45873.857680023146 44 26.4457 34.7936 65.0454 66.0726 36.0370 38.5787 34.2818 63.8392 66.5933 47.0557 36.7496
45873.857737893515 45 26.3824 34.9253 65.4277 66.5434 36.1979 38.8596 34.4529 64.2052 67.0330 47.4717 36.9631
45873.85779576389 46 26.4645 35.0628 65.6161 67.0157 36.4880 39.0726 34.6363 64.6261 67.4353 47.7310 37.1417

Frequently Asked Questions

Are these values taken from the source report?

Yes. The displayed measurements are taken from the extracted source workbook and are not estimated.

Is the complete test range represented?

Yes. The table includes the available test groups and pressure or time ranges recorded in the source sheet.

Further Reading & Standards

Use the following ETENWOLF test reports, product information and measurement references to interpret this report in context.

Related ETENWOLF Documents

Product Information