Document Overview
Key Findings All three C2 samples completed multiple high-pressure cyclic discharge cycles from 0 to 150 psi using a 0.6 L cylinder, with discharge times increasing progressively across cycles — consistent with normal battery depletion under repeated load. Product: ETENWOLF C2 Tire Inflator Test Type:…
- Document type
- Test Report
- Prepared by
- Daniel Wright
- Published
- Last reviewed
- Topics
- Others
Key Findings
All three C2 samples completed multiple high-pressure cyclic discharge cycles from 0 to 150 psi using a 0.6 L cylinder, with discharge times increasing progressively across cycles — consistent with normal battery depletion under repeated load.
- Product: ETENWOLF C2 Tire Inflator
- Test Type: High-Pressure Cyclic Discharge (高压循环放电测试)
- Cylinder Volume: 0.6 L
- Pressure Range: 0–150 psi
- Samples Tested: 3 units (1#, 2#, 3#)
- Discharge Rounds: First discharge (第一次放电测试) and Second full-charge discharge (第二次充满放电测试)
- Cycle Counts — Round 1: 1# = 8 cycles, 2# = 7 cycles, 3# = 8 cycles
- Cycle Counts — Round 2: 1# = 9 cycles, 2# = 8 cycles, 3# = 8 cycles
- Verdict: All samples performed within expected parameters across both discharge rounds
Test Overview
| Field | Details |
|---|---|
| Test Name | C2PV High-Pressure Cyclic Discharge Test (0.6 L Cylinder, 0–150 psi) |
| Original Title | C2PV-高压循环放电测试(0.6L气缸0-150psi) |
| Model | C2 |
| Product Line | Inflation Tools |
| Source File | C2PV-高压循环放电测试-2025.11.2.xls |
| Test Date | 2025-11-02 |
| Manufacturer | ETENWOLF |
| Samples | 3 units (1#, 2#, 3#) |
| Cylinder Volume | 0.6 L |
| Pressure Range | 0–150 psi |
| Discharge Rounds | 2 (First discharge; Second discharge after full recharge) |
Test Equipment & Setup
| Parameter | Value |
|---|---|
| Product Model | ETENWOLF C2 Tire Inflator |
| Cylinder Volume | 0.6 L |
| Pressure Range | 0–150 psi |
| Number of Samples | 3 |
| Discharge Test Rounds | 2 (First discharge; Second discharge after full recharge) |
| Maximum Cycles per Round | 10 |
| Time Unit Recorded | Days (decimal fraction, converted to seconds in analysis) |
| Data Recording Method | Per-cycle elapsed time logged for each sample |
Test Procedure
- Pre-Test: Verify each sample (1#, 2#, 3#) is fully charged before the first discharge round.
- Setup: Connect the 0.6 L cylinder to the C2 unit. Set target pressure to 150 psi starting from 0 psi.
- First Discharge Round (第一次放电测试): Run the unit through consecutive inflation cycles. Record elapsed time (in fractional days) for each cycle. Continue until the battery is exhausted. Record the total number of completed cycles.
- Recharge: Fully recharge each sample unit before proceeding to the second round.
- Second Discharge Round (第二次充满放电测试): Repeat the cyclic inflation procedure under identical conditions. Record elapsed time for each cycle and total cycle count until battery exhaustion.
- Post-Test: Inspect each sample for physical anomalies. Record all cycle times and counts in the data sheet.
- Acceptance Criteria: Each sample must complete multiple cycles in both rounds; elapsed time per cycle should increase monotonically, reflecting normal battery depletion under repeated high-pressure load.
Test Data & Results
First Discharge Test (第一次放电测试) — Test Time (days)
| Sample No. | Cycle 1 | Cycle 2 | Cycle 3 | Cycle 4 | Cycle 5 | Cycle 6 | Cycle 7 | Cycle 8 | Cycle 9 | Cycle 10 | Total Cycles |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1# | 0.06944 | 0.07014 | 0.07431 | 0.07778 | 0.08056 | 0.08333 | 0.08611 | 0.08750 | — | — | 8 |
| 2# | 0.07222 | 0.07569 | 0.07986 | 0.08472 | 0.08819 | 0.09028 | 0.09306 | — | — | — | 7 |
| 3# | 0.05694 | 0.05833 | 0.06806 | 0.07153 | 0.07500 | 0.07778 | 0.07986 | 0.08264 | — | — | 8 |
Observations (Round 1): All three samples show a consistent upward trend in per-cycle elapsed time, confirming progressive battery depletion under repeated 0–150 psi loading. Sample 2# completed 7 cycles before exhaustion; samples 1# and 3# each completed 8 cycles.
Second Full-Charge Discharge Test (第二次充满放电测试) — Test Time (days)
| Sample No. | Cycle 1 | Cycle 2 | Cycle 3 | Cycle 4 | Cycle 5 | Cycle 6 | Cycle 7 | Cycle 8 | Cycle 9 | Cycle 10 | Total Cycles |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1# | 0.04444 | 0.05069 | 0.06806 | 0.07083 | 0.07569 | 0.07917 | 0.08194 | 0.08472 | 0.08889 | — | 9 |
| 2# | 0.05417 | 0.06389 | 0.07083 | 0.07431 | 0.07986 | 0.08750 | 0.09236 | 0.09931 | — | — | 8 |
| 3# | 0.04792 | 0.05208 | 0.06250 | 0.06806 | 0.07361 | 0.07847 | 0.08125 | 0.08472 | — | — | 8 |
Observations (Round 2): After a full recharge, all samples again demonstrated monotonically increasing cycle times. Sample 1# extended to 9 cycles in this round; samples 2# and 3# completed 8 cycles each. Cycle times in Round 2 are generally comparable to Round 1, indicating consistent battery capacity retention between charges.
Conclusion
| Item | Details |
|---|---|
| Test | High-Pressure Cyclic Discharge (0.6 L, 0–150 psi) |
| Samples | 3 units (1#, 2#, 3#) |
| Round 1 Cycle Counts | 1# = 8, 2# = 7, 3# = 8 |
| Round 2 Cycle Counts | 1# = 9, 2# = 8, 3# = 8 |
| Time Trend | Monotonically increasing per cycle in both rounds — consistent with normal depletion |
| Battery Retention | Cycle counts and times are consistent between Round 1 and Round 2, indicating stable capacity |
| Verdict | PASS — All samples performed within expected parameters across both discharge rounds |
Document Information
| Role | Name | Details |
|---|---|---|
| Author / Tester | Daniel Wright | Translated and structured from source file C2PV-高压循环放电测试-2025.11.2.xls |
| Source File Date | — | 2025-11-02 |
| Publication Date | — | 2026-07-12 |
| Form / File Reference | — | C2PV-高压循环放电测试-2025.11.2.xls |
| Product Line | — | Inflation Tools |
| Term ID | — | 97 |
Frequently Asked Questions
What does the ETENWOLF C2 high-pressure cyclic discharge test measure?
The test measures how many consecutive inflation cycles the C2 can complete when pressurizing a 0.6 L cylinder from 0 to 150 psi on a single battery charge. Elapsed time per cycle is recorded to track battery depletion under repeated high-pressure load.
How many cycles did the ETENWOLF C2 complete in the discharge test?
Across two discharge rounds, the three test samples completed between 7 and 9 cycles each. In Round 1 (first discharge): 1# completed 8 cycles, 2# completed 7, and 3# completed 8. In Round 2 (after full recharge): 1# completed 9 cycles, 2# completed 8, and 3# completed 8.
Why do cycle times increase with each successive cycle in the C2 discharge test?
As the battery depletes under repeated high-pressure load, the motor delivers slightly less power per cycle, causing each successive inflation cycle to take marginally longer. A monotonically increasing time trend is the expected and normal result, confirming the battery is discharging progressively rather than failing abruptly.
Is the ETENWOLF C2 battery capacity consistent between charges?
Yes. The Round 2 discharge results (after a full recharge) show cycle counts and per-cycle times comparable to Round 1, indicating stable battery capacity retention between charge cycles for all three samples tested.
Related Products
Explore other ETENWOLF inflation tools and related test reports:
- ETENWOLF Official Website
- More reports by Daniel Wright