Document Overview

Document Overview This page presents the FCC Supplier’s Declaration of Conformity (SDoC) test report for the ETENWOLF P100 Ball Pump, issued by Waltek Testing Group (Shenzhen) Co., Ltd. The report reference number is WTH25X04098554E, and the test report form number is WTX_FCC PART15B_001. The document…

Document type
User Manual
Prepared by
Michelle Torres
Published
Last reviewed
Topics
North America: FCC / UL

Document Overview

This page presents the FCC Supplier’s Declaration of Conformity (SDoC) test report for the ETENWOLF P100 Ball Pump, issued by Waltek Testing Group (Shenzhen) Co., Ltd. The report reference number is WTH25X04098554E, and the test report form number is WTX_FCC PART15B_001.

The document covers electromagnetic emission testing performed under 47 CFR FCC Part 15, Subpart B — Unintentional Radiators. The overall test result is Pass. The scope of the report includes conducted emissions on AC mains and radiated emissions below 1 GHz, covering the product in both charge mode and working mode.

Field Detail
Report Reference No. WTH25X04098554E
Certificate Type FCC SDoC (Supplier’s Declaration of Conformity)
Issuing Body Waltek Testing Group (Shenzhen) Co., Ltd.
Date of Issue 2025-04-23
Report Version Rev.00 — Original
Test Result Pass
Standard Applied 47 CFR FCC Part 15, Subpart B

Product Information

The equipment under test (EUT) is the ETENWOLF P100 Ball Pump, manufactured and supplied by Guangdong Bestek Technology Co., Ltd. The product is classified as a Class B unintentional radiator under FCC rules, meaning it is designed for use in residential environments where stricter emission limits apply.

Attribute Value
Product Name Ball Pump
Model No. P100
Trade Name
Additional Models
Applicant Guangdong Bestek Technology Co., Ltd.
Manufacturer Guangdong Bestek Technology Co., Ltd.
Manufacturer Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China
Power Supply (Input) DC 5V
Battery DC 3.7V
Highest Internal Frequency Below 108 MHz
FCC Equipment Classification Class B

The test data was gathered from a production sample provided by the manufacturer. No power adaptor or rated current specifications were designated for this EUT beyond what is listed above.

Key Details

Testing was conducted from 2025-04-18 to 2025-04-22, with the sample received on 2025-04-18. The report was issued on 2025-04-23. Two test modes were defined to capture the highest possible emission levels from the EUT.

EUT Operation Modes

Mode ID Title Description
TM1 Charge Mode DC 5V via adapter input AC 120V/60Hz
TM2 Working Mode DC 3.7V (battery powered)

Auxiliary Equipment Used

Description Manufacturer Model Serial Number
Adapter Xiaomi MDY-12-EQ QA622020106645G

Measurement Uncertainty

Test Item Measurement Uncertainty
Conducted Emissions (AC Mains 150 kHz – 30 MHz) ±3.34 dB
Radiated Emissions (30 MHz – 200 MHz) ±4.52 dB
Radiated Emissions (200 MHz – 1000 MHz) ±5.56 dB

Test Scope Summary

  • Conducted emissions on AC mains (Section 3.1)
  • Radiated emissions below 1 GHz (Section 3.2)
  • Product labeling review (Exhibit 1)
  • EUT photographs (Exhibit 2)
  • Test setup photographs (Exhibit 3)
  • User manual review (Exhibit 4)

Standards & Compliance

The ETENWOLF P100 was tested in accordance with the following regulatory standard:

Standard Scope Classification
47 CFR FCC Part 15, Subpart B Unintentional Radiators — conducted and radiated emissions limits Class B Digital Device

Class B devices are held to more stringent emission limits than Class A devices because they are marketed for use in residential settings. Compliance with FCC Part 15 Subpart B ensures the P100 does not cause harmful electromagnetic interference to licensed radio communications.

Per FCC requirements, maintenance of compliance after the initial certification is the ongoing responsibility of the manufacturer. Any product modification that could affect emission or immunity performance must be re-evaluated to confirm continued compliance.

Validity & Certification Body

The test report was prepared and approved by Waltek Testing Group (Shenzhen) Co., Ltd., an FCC-registered test laboratory operating a 3-meter semi-anechoic chamber.

Field Detail
Laboratory Waltek Testing Group (Shenzhen) Co., Ltd.
Lab Address 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70, Bao’an District, Shenzhen, Guangdong, China
FCC Registration No. 125990
FCC Designation No. CN5010
Industry Canada (IC) Registration No. 11464A
IC CAB Identifier CN0057
Report Prepared By Toby Zhang — Project Engineer
Report Approved By Evan Cai — Manager
Contact Tel: +86-755-33663308 | Email: [email protected]

The report is valid as an original document only when it bears the specific stamp of the test institute and the signatures of the approver. Reproduction is not permitted without prior written permission from Waltek Testing Group. The report version Rev.00, issued on 2025-04-23, is the original and only version on record.

Frequently Asked Questions

What does FCC Part 15 Subpart B compliance mean for the P100 Ball Pump?

It means the ETENWOLF P100 Ball Pump has been tested and confirmed to meet the FCC Part 15 Subpart B limits for unintentional electromagnetic emissions. As a Class B device, it is approved for residential use without causing harmful interference to radio communications.

What test house conducted the FCC testing and is it accredited?

Testing was conducted by Waltek Testing Group (Shenzhen) Co., Ltd., an FCC-registered laboratory with FCC Test Firm Registration Number 125990 and Designation Number CN5010. The facility also holds Industry Canada registration number 11464A, confirming its accreditation for North American market compliance testing.

Which emission tests were performed on the P100?

Two categories of emission tests were performed: conducted emissions on AC mains (covering 150 kHz to 30 MHz) and radiated emissions below 1 GHz (covering 30 MHz to 1000 MHz). Both tests were conducted in charge mode (TM1) and working mode (TM2) to capture the highest possible emission levels.

Can the FCC test report be used as a standalone compliance declaration?

The report supports the FCC Supplier’s Declaration of Conformity (SDoC) process. It is valid only as a complete document bearing the lab’s official stamp and the approver’s signature. It cannot be partially reproduced. For full regulatory compliance, the report is used alongside the FCC SDoC declaration filed by the responsible party.

Related Documents

The following certification and compliance documents are relevant for the ETENWOLF P100 Ball Pump and are recommended to complete a full regulatory compliance package for global market access:

  • CE Declaration of Conformity — Required for the European market; covers electromagnetic compatibility (EMC) under EN 55032 and related directives.
  • RoHS Compliance Report — Confirms restriction of hazardous substances per EU RoHS Directive 2011/65/EU.
  • REACH SVHC Declaration — Addresses substance of very high concern requirements under REACH Regulation (EC) No 1907/2006.
  • UN38.3 Battery Test Report — Required for transport certification of the built-in DC 3.7V lithium battery under UN38.3 regulations.
  • KC Certification — Required for the South Korean market, covering electromagnetic compatibility and safety of electrical products.
  • Product Safety Test Report (IEC/EN 62368-1) — Audio/video, information, and communication technology equipment safety standard applicable to battery-powered electronic devices.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22
Document Page 23
Document Page 24
Document Page 25