Document Overview
Key Findings All three S6V cordless inflator samples measured between 83.6 dB and 84.2 dB at 1 m front-face distance, falling within the evaluated sound pressure range of 35–100 dB. Results are provided for reference only under internal standard criteria. Product: ETENWOLF S6V Electric Cordless…
- Document type
- Test Report
- Prepared by
- Daniel Wright
- Published
- Last reviewed
- Topics
- Noise Testing
Key Findings
All three S6V cordless inflator samples measured between 83.6 dB and 84.2 dB at 1 m front-face distance, falling within the evaluated sound pressure range of 35–100 dB. Results are provided for reference only under internal standard criteria.
- Product: ETENWOLF S6V Electric Cordless Inflator
- Test Type: Reliability Test — Noise / Vibration Assessment
- Standard: Internal Standard (sound pressure level Lmax 35–100 dB)
- Samples Tested: 3 PCS
- Measurement Distance: 1 m (microphone to front face, horizontal)
- Result Range: 83.6 dB – 84.2 dB
- Verdict: For Reference Only
Test Overview
| Field | Detail |
|---|---|
| Report Title | Environmental Noise Test Report |
| Report No. | 2025090601 |
| Test Date | 2025-09-06 |
| Product No. / Name | Electric Cordless Inflator |
| Model / Type Specification | S6V |
| Product Page | ETENWOLF Vortex S6 Heavy-Duty Cordless Inflator |
| Sample Quantity / No. | 3 PCS |
| Type of Test | Reliability Test (■) — EMC Test, Safety Test, and Functional Test were not selected |
| Test Standard | Internal Standard |
| Test Purpose | Evaluate motor noise and vibration under different operating scenarios |
| Acceptance Criterion | Sound pressure level Lmax 35–100 dB |
| Test Conditions | Room Temperature 23 °C, Relative Humidity 60 % |
Test Equipment & Setup
| Item | Detail |
|---|---|
| Test Equipment | Sound Level Meter (Noise Meter) |
| Measurement Position | Front face of product |
| Microphone Distance | 1 m horizontal from product front face |
| Product State During Test | Powered on (operating state) |
| Ambient Temperature | 23 °C |
| Relative Humidity | 60 % |
| Remarks / Notes | — |
Test Procedure
- Pre-test: Confirm ambient conditions — room temperature 23 °C, relative humidity 60 %. Verify sound level meter calibration and positioning.
- Sample preparation: Label three S6V units as 1#, 2#, and 3#.
- Microphone placement: Position microphone at 1 m horizontal distance from the front face of the unit under test.
- Power on: Start the inflator and allow it to reach normal operating state.
- Measurement: Record peak sound pressure level (dB) displayed on the noise meter for each sample.
- Repeat: Perform the same measurement for samples 2# and 3# under identical conditions.
- Post-test: Power off each sample. Record all readings in the test log.
- Acceptance evaluation: Compare readings against the internal standard criterion of Lmax 35–100 dB and assign verdict.
Test Data & Results
| Sample No. | Direction | Distance to Microphone | Noise (dB) |
|---|---|---|---|
| 1# | Front Face (正面) | 1 M | 84.2 |
| 2# | Front Face (正面) | 1 M | 83.7 |
| 3# | Front Face (正面) | 1 M | 83.6 |
Observations: All three samples recorded noise levels between 83.6 dB and 84.2 dB, a spread of 0.6 dB. All readings fall within the evaluated sound pressure range of 35–100 dB. No anomalous vibration or noise events were noted during testing. Test images were captured but are not reproduced here.
Conclusion
| Item | Detail |
|---|---|
| Result Range | 83.6 dB – 84.2 dB |
| Evaluated Standard | Internal Standard — Sound Pressure Level Lmax 35–100 dB |
| Test Conditions | 23 °C, 60 % RH, 1 m front-face, product powered on |
| Samples | 3 PCS (S6V) |
| Verdict | For Reference Only (■ 供参考) — Pass and Fail checkboxes were not selected |
Document Information
| Role | Name (Pinyin) | Date |
|---|---|---|
| Tested By (测试/日期) | Li Guanghua | 2025-09-06 |
| Checked By (审核/日期) | Zhang Ronggui | 2025-09-06 |
| Approved By (核准/日期) | Mai Shaoqiang | 2025-09-06 |
| Form / Source File | S6VE充气泵-噪音测试 2025.9.6.xlsx | — |
| Report No. | 2025090601 | — |
Frequently Asked Questions
How loud is the ETENWOLF S6 cordless inflator during operation?
In controlled lab conditions at 1 m front-face distance, the S6V measured between 83.6 dB and 84.2 dB across three samples. This is comparable to a busy street or vacuum cleaner. Hearing protection is advisable for extended continuous use in enclosed spaces.
What test standard was used for the S6 noise measurement?
The test followed ETENWOLF’s internal standard, which evaluates sound pressure level across a range of Lmax 35–100 dB. The microphone was placed 1 m horizontally from the product’s front face while the unit was powered on and operating.
Did the ETENWOLF S6 pass its noise test?
The three S6V samples were assessed under the workplace noise exposure evaluation framework. The report verdict is For Reference Only — neither a formal Pass nor Fail was assigned, meaning the data serves as a baseline characterization rather than a compliance determination against a mandatory limit.
What environmental conditions were maintained during the S6 noise test?
Testing was conducted at room temperature of 23 °C and 60 % relative humidity. These conditions are standard for reliability testing and ensure consistent, repeatable acoustic measurements.