ETENWOLF S1 Portable Tire Inflator LED Illuminance Test Report (10 cm, Front White Light)

Document Overview

Key Findings The ETENWOLF S1 portable tire inflator’s built-in LED lamp was measured at a maximum illuminance of 286 LUX at 10 cm distance in a darkroom environment, with both samples performing consistently and the report filed for reference. Product: ETENWOLF S1 Portable Tire Inflator…

Document type
Test Report
Prepared by
Daniel Wright
Published
Last reviewed
Topics
Illuminance Testing

Key Findings

The ETENWOLF S1 portable tire inflator’s built-in LED lamp was measured at a maximum illuminance of 286 LUX at 10 cm distance in a darkroom environment, with both samples performing consistently and the report filed for reference.

  • Product: ETENWOLF S1 Portable Tire Inflator (Air Pump)
  • Test Type: Reliability Test — LED Illuminance Measurement
  • Distance: 10 cm from light source
  • Light Mode: Front white light (正面白光)
  • Sample 1 (1#): 277 LUX
  • Sample 2 (2#): 286 LUX
  • Test Standard: Internal standard — range and luminous intensity uniformity evaluation
  • Verdict: For Reference Only

Test Overview

Field Detail
Report Title Illuminance Value Test Report (照度值测试报告)
Product No. / Name Air Pump (充气泵) — ETENWOLF S1 Portable Tire Inflator
Report No. 2025081601
Test Date 2026-08-16
Type Specification S1
Sample Quantity / No. 2 PCS
Type of Test ■ Reliability Test (可靠性测试)
Test Standard (Basis) Internal Standard (内部标准)
Test Purpose Evaluate the maximum illuminance value of the sample’s LED lamp (评估样品LED灯照度最大值)
Test Procedure Summary Measure the maximum value on the optical axis light at a distance of 10 cm using an illuminance meter in a darkroom (距离10厘米,在暗室中用照度计测量光轴灯光上的最大值)
Test Criteria Range and luminous intensity uniformity evaluation (射程与光强均匀性评估)
Manufacturer / Brand ETENWOLF

Test Equipment & Setup

Item Detail
Test Equipment Illuminance Meter (照度计, unit: LX / LUX)
Measurement Distance 10 cm
Measurement Location Darkroom, on the optical axis of the LED lamp
Light Mode Tested Front white light (正面白光)
Room Temperature 23 °C
Relative Humidity 60 %
Test Conditions Label ROOM TEMP. & HUMIDITY: 23 °C, 60 %
Photo Reference 10 cm LED high-brightness photo (10cm LED高亮); image reference index: 9

Test Procedure

  1. Pre-Test: Prepare 2 PCS S1 samples. Allow samples to acclimatize to room temperature (23 °C) and humidity (60 %) conditions.
  2. Equipment Setup: Power on the calibrated illuminance meter (LX unit). Position the meter probe on the optical axis of the LED lamp at exactly 10 cm from the light-emitting surface.
  3. Environment: Conduct all measurements inside a darkroom to eliminate ambient light interference.
  4. Measurement: Activate the front white light mode on each sample. Record the maximum illuminance value (LUX) displayed on the illuminance meter for each sample individually.
  5. Post-Test: Record results, capture test photos (reference: 10 cm LED high-brightness image), and evaluate uniformity of range and luminous intensity.
  6. Acceptance Criteria: Results are evaluated against range and luminous intensity uniformity standards. This test is classified as For Reference Only (供参考).

Test Data & Results

Sample No. (编号) Distance (cm) (距离) Light Mode (灯光) Illuminance Value / LUX (照度值)
1# 10 Front white light (正面白光) 277
2# 10 Front white light (正面白光) 286

Observations: Both samples were tested under identical conditions (10 cm distance, front white light, darkroom). Sample 1# registered 277 LUX and Sample 2# registered 286 LUX, yielding a spread of 9 LUX between the two units. The test image (10cm LED高亮, index 9) was captured for visual documentation. Remarks/Notes field was left blank by the tester.

Conclusion

Field Detail
Result Classification ■ For Reference Only (供参考)
Pass / Fail ☐ Pass (合格) — not checked; ☐ Fail (不合格) — not checked
Test Standard Applied Internal standard — range and luminous intensity uniformity evaluation
Test Conditions Darkroom, 10 cm distance, front white light, 23 °C / 60 % RH
Samples Tested 2 PCS (1#: 277 LUX; 2#: 286 LUX)
Verdict Data recorded for reference. No pass/fail threshold formally applied in this report.

Document Information

Role Name (Pinyin) Date
Tested By (测试/日期) Li Guanghua 2025-08-16
Checked By (审核/日期) Zhang Ronggui 2025-08-16
Approved By (核准/日期) Mai Shaoqiang 2025-08-16
Source File S1-_光照度测试2025.8.16.xlsx
Sheet Name 照度值测试 (Sheet 1 of 1)
Report No. 2025081601

Frequently Asked Questions

What illuminance does the ETENWOLF S1 LED light produce at 10 cm?

In controlled darkroom testing at 10 cm distance, the ETENWOLF S1’s front white LED lamp measured between 277 LUX and 286 LUX across two production samples, with a maximum recorded value of 286 LUX.

What test standard was used for the S1 LED illuminance test?

The test was conducted against ETENWOLF’s internal standard focused on range and luminous intensity uniformity evaluation. No external standard (such as IEC or ISO) was referenced for this specific test; results are filed for reference only.

What equipment was used to measure the S1 LED brightness?

An illuminance meter (照度计) measuring in LUX was used. Measurements were taken in a darkroom at exactly 10 cm from the LED light source on the optical axis to ensure accuracy and eliminate ambient light interference.

Does the ETENWOLF S1 tire inflator have a functional LED light?

Yes. The ETENWOLF S1 portable tire inflator includes a built-in front white LED lamp. Based on illuminance testing, it delivers up to 286 LUX at 10 cm, making it suitable for use in low-light conditions such as roadside tire inflation at night.

Related Products