Document Overview
Key Findings All three HB3 hair dryer samples measured front-face sound pressure levels between 83.2 dB and 84.0 dB at 1 m distance, falling within the evaluated range of 35–100 dB; results are provided for reference only per internal standard. Product: HB3 Hair Dryer Report…
- Document type
- Test Report
- Prepared by
- Alex Newman
- Published
- Last reviewed
- Topics
- Noise Testing
Key Findings
All three HB3 hair dryer samples measured front-face sound pressure levels between 83.2 dB and 84.0 dB at 1 m distance, falling within the evaluated range of 35–100 dB; results are provided for reference only per internal standard.
- Product: HB3 Hair Dryer
- Report No.: 2025052101
- Test Date: 2025-05-21
- Samples: 3 PCS
- Measurement direction: Front face
- Microphone distance: 1 m
- Range tested: 83.2 – 84.0 dB
- Acceptance band: Lmax 35–100 dB
- Verdict: For Reference Only
Test Overview
| Field | Detail |
|---|---|
| Report Title | Noise Test Report |
| Product No. / Name | HB3 Hair Dryer |
| Report No. | 2025052101 |
| Test Date | 2025-05-21 |
| Model / Type Specification | HB3 |
| Sample Quantity / No. | 3 PCS |
| Type of Test | ■ Reliability Test |
| Test Standard | Internal Standard |
| Test Purpose | Evaluate the noise level of the sample under different operating scenarios |
| Test Procedure (summary) | With the product powered on, measure noise level with the microphone positioned 1 m horizontally from the front face of the product |
| Acceptance Criterion | Evaluate sound pressure level of noise source (Lmax 35–100 dB) |
| Test Equipment | Sound Level Meter (Noise Meter) |
| Test Conditions | Room Temperature: 23 °C; Relative Humidity: 60% |
Test Equipment & Setup
| Parameter | Value |
|---|---|
| Instrument | Sound Level Meter (Noise Meter) |
| Measurement Quantity | Sound Pressure Level (SPL) |
| Microphone Distance from Product | 1 m (horizontal, front face) |
| Measurement Direction | Front face (正面) |
| Acceptance Band (Lmax) | 35 dB – 100 dB |
| Ambient Temperature | 23 °C |
| Relative Humidity | 60% |
| Product Operating State | Powered on (normal operation) |
Test Procedure
- Pre-test: Confirm ambient conditions are 23 °C and 60% RH. Verify the sound level meter is calibrated and functional.
- Sample preparation: Label samples 1#, 2#, and 3#. Place each HB3 hair dryer on a stable surface in the test environment.
- Microphone placement: Position the microphone 1 m horizontally from the front face of the product at the same height as the air outlet.
- Measurement: Power on the product. Record the maximum sound pressure level (dB) displayed on the noise meter for each sample.
- Repeat: Perform the measurement for all three samples in sequence under identical conditions.
- Post-test: Power off each sample after measurement. Record all readings in the test data table.
- Acceptance criteria: Measured Lmax must fall within 35–100 dB. Final verdict is issued as Pass, Fail, or For Reference Only based on the evaluation.
Test Data & Results
| Sample No. | Direction | Distance from Microphone | Noise Level (dB) |
|---|---|---|---|
| 1# | Front face | 1 m | 84.0 |
| 2# | Front face | 1 m | 83.2 |
| 3# | Front face | 1 m | 83.4 |
Observations: All three samples produced consistent readings within a 0.8 dB spread. The highest recorded value was 84.0 dB (Sample 1#) and the lowest was 83.2 dB (Sample 2#). All values fall comfortably within the evaluated acceptance band of 35–100 dB. No anomalies or outliers were observed during testing. Results are designated For Reference Only per the internal standard classification.
Conclusion
| Field | Detail |
|---|---|
| Test Item | Noise Level — Sound Pressure Level (SPL) |
| Standard / Criterion | Internal Standard — Lmax 35–100 dB |
| Test Conditions | Front face, 1 m distance, 23 °C, 60% RH, product powered on |
| Samples Tested | 3 PCS (1#, 2#, 3#) |
| Results | 84.0 dB / 83.2 dB / 83.4 dB |
| Pass / Fail Verdict | ☐ Pass (合格) ☐ Fail (不合格) ■ For Reference Only (供参考) |
Document Information
| Role | Name (Pinyin) | Date |
|---|---|---|
| Tested By (测试/日期) | Li Guanghua | 2025-05-21 |
| Checked By (审核/日期) | Zhang Ronggui | 2025-05-21 |
| Approved By (核准/日期) | Mai Shaoqiang | 2025-05-21 |
| Form / Report No. | 2025052101 | — |
Frequently Asked Questions
What noise level did the ETENWOLF HB3 hair dryer measure during testing?
The HB3 measured between 83.2 dB and 84.0 dB at 1 m from the front face during powered-on operation, across all three test samples.
What standard was used for the HB3 noise test?
The test followed ETENWOLF’s internal standard, evaluating sound pressure level against an acceptance band of Lmax 35–100 dB.
Why is the HB3 noise test result listed as ‘For Reference Only’ rather than Pass or Fail?
The internal test classification designated the result as ‘For Reference Only’ (供参考), meaning the data is used to characterize the product’s acoustic performance rather than to certify compliance with a mandatory regulatory limit.
At what distance and direction was the noise measurement taken for the HB3?
The microphone was placed 1 m horizontally from the front face of the product while it was powered on under standard room conditions of 23 °C and 60% relative humidity.
Related Products
- ETENWOLF Official Website — explore the full range of ETENWOLF hair care and inflation tools
- ETENWOLF HB3 Hair Dryer — product details and specifications