Document Overview
Document Overview This page presents the official UL 2743 test report issued for the ETENWOLF Helios J1 Portable Automotive Jump Starter. The report was prepared by Waltek Testing Group Co., Ltd., an accredited third-party testing laboratory located at No. 77, Houjie Section, Guantai Road, Houjie…
- Document type
- Certification Report
- Prepared by
- Michelle Torres
- Published
- Last reviewed
- Topics
- North America: FCC / UL
Document Overview
This page presents the official UL 2743 test report issued for the ETENWOLF Helios J1 Portable Automotive Jump Starter. The report was prepared by Waltek Testing Group Co., Ltd., an accredited third-party testing laboratory located at No. 77, Houjie Section, Guantai Road, Houjie Town, Dongguan City, Guangdong, China.
- Reference Number: WTH25D05119733R1S001
- Document Type: Test Report
- Applicable Standard: ANSI/CAN/UL 2743:2023
- Date of Sample Receipt: 2025-05-14
- Date of Testing: 2025-05-14 to 2025-05-27
- Date of Issue: 2025-06-25
- Overall Test Result: PASS
- Applicant / Manufacturer: Guangdong Bestek Technology Co., LTD, No. 1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China
This report supersedes original report WTH25D05119733S001 (dated 2025-05-30). The revision (R1, dated 2025-06-25) was issued solely to update the product name and model designation; no additional testing was required following the review.
Product Information
The ETENWOLF Helios J1 is a compact, portable power pack designed to jump-start automotive vehicles. It combines a high-current jump-start output with multi-protocol USB charging ports and integrated LED flashlights, making it a versatile roadside emergency tool.
| Attribute | Detail |
|---|---|
| Product Category | Portable Automotive Jump Starter |
| Brand / Model | ETENWOLF Helios J1 |
| Trade Mark | None declared |
| Battery Capacity | 59.2 Wh |
| Cell Configuration | 4 cells in series (4S1P) |
| Start Current | 240 A |
| Peak Current | 800 A |
| Type-C Input / Output | 5 V DC / 3 A, 9 V DC / 3 A, 12 V DC / 2.5 A, 15 V DC / 2 A, 20 V DC / 1.5 A |
| USB-A Output | 5 V DC / 3 A, 9 V DC / 2 A, 12 V DC / 1.5 A |
| Operating Temperature | 0 °C to 40 °C |
| Equipment Mobility | Portable |
| Operating Condition | Continuous |
| Mass | Approx. 0.79 kg + 0.24 kg (booster cable) |
| Ports | 1× Type-C (input/output), 1× USB-A (output), 1× jump-start output, 2× LED flashlight |
Note: The USB-A and Type-C ports cannot be loaded simultaneously.
Key Details
All applicable test clauses under ANSI/CAN/UL 2743:2023 were performed at Waltek’s Dongguan facility. The table below summarises each tested clause, the method applied, and the verdict.
| Clause | Test Name | Method / Condition | Result | Verdict |
|---|---|---|---|---|
| 42 | Power Input Test | Per standard appended table | Compliant | Pass |
| 43 | Normal Charging Operation Test | Per standard appended table | Compliant | Pass |
| 47 | Normal Temperature Test | Maximum normal load; power pack ampacity temperature test | Compliant | Pass |
| 50.2 | Output Connections Short Circuit Test | Per standard appended table | Compliant | Pass |
| 50.3 | Reverse Polarity of Booster Cables | Booster cable connections reverse-connected to a fully charged battery | Internal protection opens; sample complies with Clause 50.1.1 | Pass |
| 50.4 | Component Faults | Per standard appended table | Compliant | Pass |
| 50.9 | Overcharging Test | Per standard appended table | Compliant | Pass |
| 51 | Vibration Test | 4 hours at 22 cycles/second, 1/4 inch (6.4 mm) displacement, vertical plane | No catch fire or explosion; complies with Clause 50.1.1 | Pass |
| 55.2 | Impact Test | Steel sphere dropped from 1.30 m height | Test probe cannot contact hazardous live parts; no fire, no explosion | Pass |
| 55.3 | Drop Test | Sample dropped 3 times from 0.9 m height | Test probe cannot contact hazardous live parts; no fire, no explosion | Pass |
| 56 | Mold Stress Test | Conditioned in oven at 70 °C for 7 hours | No distortion, deterioration, shrinkage, warping, or softening that would expose live parts | Pass |
| 65 | Power Pack Ampacity Test | Per standard | Compliant | Pass |
| 67 | Cold Bend Test | Per standard | Compliant | Pass |
| 68 | Clamp Tests | Per standard | Compliant | Pass |
Clauses deemed not applicable (N/A) include: Clause 44 (Lithium Charging System Test), Clause 45 (Capacitor Discharge Test), Clause 46 (Leakage Current Test), Clause 48 (Dielectric Voltage Withstand Test), Clause 50.5 (Relay and Solenoid Burnout — approved relay used), Clause 50.7 (Disconnected Fan Test — no fan), Clause 50.8 (Blocked Ventilation Test — no ventilation), Clause 50.10 (Internal Battery Reverse Polarity — construction prevents reverse connection), Clause 50.11 (Thermal Propagation Test), and Clause 54 (Strain Relief — detachable power cord used).
Standards & Compliance
The ETENWOLF Helios J1 was tested against the following standard:
- ANSI/CAN/UL 2743:2023 — Standard for Portable Power Packs. This is the primary North American safety standard covering portable automotive jump starters and power packs, addressing electrical, mechanical, thermal, and abnormal-operation hazards.
Key test disciplines covered under this standard and applied to the Helios J1 include:
- Electrical performance: power input, normal charging, short-circuit output, overcharging, and reverse-polarity protection.
- Thermal safety: normal temperature test, mold stress test, and cold bend test.
- Mechanical safety: vibration, impact, and drop tests to verify enclosure integrity and absence of exposed live parts.
- Clamp and ampacity: booster cable clamp tests and power pack ampacity verification to confirm safe current-carrying capacity.
All subcontracting decisions for test items were confirmed as none — all tests were conducted entirely at the Waltek Dongguan facility.
Validity & Certification Body
Issuing Laboratory: Waltek Testing Group Co., Ltd.
Website: www.waltek.com.cn
Address: No. 77, Houjie Section, Guantai Road, Houjie Town, Dongguan City, Guangdong, China
Tel: +86-769-2267 6998 | Fax: +86-769-2267 6828
- Compiled by: Lucas Cao, Project Engineer
- Approved by: Sam Qi, Designated Reviewer
- Original Report: WTH25D05119733S001, dated 2025-05-30
- Revised Report: WTH25D05119733R1S001, dated 2025-06-25 (product name and model update; no re-testing required)
- Total Pages: 12 pages + 3 pages photo documentation
This test report is valid only for the specific sample(s) tested. It may not be reproduced except in full, and only with prior written permission from Waltek Testing Group Co., Ltd. The report is invalid without the test institute’s official stamp and the signatures of both the compiler and the approver.
Frequently Asked Questions
- Q: What does it mean that the Helios J1 passed ANSI/CAN/UL 2743:2023?
-
Passing ANSI/CAN/UL 2743:2023 means the ETENWOLF Helios J1 has been independently verified to meet the North American safety standard for portable power packs and automotive jump starters. The testing covered electrical hazards (short circuit, reverse polarity, overcharging), mechanical hazards (drop, impact, vibration), and thermal stress — confirming the device operates safely under both normal and abnormal conditions.
- Q: Who conducted the UL 2743 testing for the Helios J1, and is the lab credible?
-
Testing was conducted by Waltek Testing Group Co., Ltd., a third-party testing laboratory based in Dongguan, Guangdong, China. Waltek is an accredited testing body that issues reports recognised for UL standard compliance. The report was compiled by a Project Engineer and reviewed by a Designated Reviewer, following a formal internal approval process.
- Q: What is the battery capacity and peak current of the Helios J1?
-
The Helios J1 has a battery capacity of 59.2 Wh, a start current of 240 A, and a peak current of 800 A. The battery uses a 4S1P cell configuration (four cells in series, one cell in parallel). Total unit weight is approximately 0.79 kg, plus 0.24 kg for the booster cable.
- Q: Can the USB-A and Type-C ports be used at the same time?
-
No. According to the product specifications documented in report WTH25D05119733R1S001, the USB-A and Type-C ports on the Helios J1 cannot be operated simultaneously. Only one output port may be loaded at a time. The Type-C port supports both input (charging the unit) and output (charging devices), while the USB-A port is output-only.
Related Documents
For a complete compliance picture of the ETENWOLF Helios J1, the following related certification and test document types are recommended:
- UN 38.3 Transport Test Report — Required for air and ground transport of lithium-ion battery products. Confirms the 4S1P cell pack meets UN 38.3 safety requirements for vibration, shock, temperature cycling, and overcharge during transportation.
- CE Declaration of Conformity (DoC) — Required for sale within the European Economic Area. Typically references IEC 62133-2 (safety for portable sealed secondary lithium cells) and the EU Low Voltage Directive.
- FCC Declaration of Conformity — Required for the US market if the device emits radio-frequency energy. Covers unintentional radiators under FCC Part 15 Subpart B.
- RoHS / REACH Compliance Statement — Confirms the product and its components are free from restricted hazardous substances under RoHS and REACH regulations.
- KC Certification (Korea) — Required for sales in South Korea; covers safety and EMC requirements for battery-powered portable devices under the KC Mark scheme.
- IEC 62619 Safety Test Report — International standard for safety requirements of secondary lithium cells and batteries used in industrial applications; relevant as a supplementary reference for the cell pack used in the Helios J1.
Document Pages