ETENWOLF S4 SUP Pump Transportation Vibration Test Report (ISTA-2A, 1 Hour Random)

Document Overview

Key Findings The ETENWOLF S4 electric SUP pump passed a 1-hour random-axis vibration test per ISTA-2A with no functional failure, no power-on anomaly, and no visible appearance defects across all three samples. Test Standard: ISTA-2A Test Duration: 1 hour Vibration Mode: Random (X, Y, Z…

Document type
Test Report
Prepared by
Daniel Wright
Published
Last reviewed
Topics
Mechanical Reliability

Key Findings

The ETENWOLF S4 electric SUP pump passed a 1-hour random-axis vibration test per ISTA-2A with no functional failure, no power-on anomaly, and no visible appearance defects across all three samples.

  • Test Standard: ISTA-2A
  • Test Duration: 1 hour
  • Vibration Mode: Random (X, Y, Z axes)
  • Frequency: 4 Hz
  • Amplitude: 25.4 mm
  • Test Speed (CMP): 240 G
  • Sample Size: 3 PCS
  • Verdict: Pass

Test Overview

Field Detail
Test Type Transportation Vibration Test
Test Standard ISTA-2A
Report No. 2025081801
Page 1
Date 2025-08-18
Product Name S4 SUP Pump (S4-浆板泵)
Manufacturer BTK
Surface Treatment /
Sample Quantity 3 PCS
Test Reason New Product
Test Objective To verify the resistance of the sample under transportation and use environments.
Laboratory Environment Temperature: 22 °C; Humidity: 55% RH

Test Equipment & Setup

Parameter Detail
Instrument Name Vibration Testing Machine
Test Mode Random Mode
Test Duration 1 H
Random Direction X, Y, Z
Vibration Frequency 4 Hz
Test Speed (CMP) 240 G
Vibration Amplitude 25.4 mm

Test Procedure

  1. Pre-Test: Confirm laboratory environment is at 22 °C and 55% RH. Inspect all 3 samples for any pre-existing appearance defects and document baseline condition. Power on each unit to verify normal operation before testing.
  2. Sample Placement: Mount samples on the vibration testing machine platform according to the vibration placement diagram (振动摆放).
  3. Vibration Test Execution: Set the machine to Random Mode across X, Y, and Z axes simultaneously. Configure frequency to 4 Hz, amplitude to 25.4 mm, and CMP speed to 240 G. Run the test for 1 continuous hour.
  4. Post-Test Inspection: After the 1-hour cycle completes, remove samples from the platform. Power on each unit and verify normal startup and electrical operation. Inspect exterior surfaces for any cracks, deformation, or cosmetic damage. Perform full functional check to confirm no feature failures.
  5. Acceptance Criteria: After vibration testing, each sample must power on normally, exhibit no functional failure, and show no abnormal appearance. Any failure in power-on, function, or appearance constitutes a Fail result.

Test Data & Results

Check Item Sample #1 Sample #2 Sample #3
Power-On After Vibration Normal Normal Normal
Functional Operation No Failure No Failure No Failure
Appearance After Vibration No Abnormality No Abnormality No Abnormality

After completing the 1-hour random vibration test, all three S4 SUP pump samples powered on correctly, operated without any functional failure, and showed no appearance anomalies. The vibration control chart (振动控制图) and pre/post-test photographic records confirm consistent performance across all axes.

Conclusion

Item Detail
Test Result After 1 hour of vibration testing, samples powered on normally with no appearance abnormalities and no functional failures.
Applicable Standard ISTA-2A
Test Conditions Random mode; X/Y/Z axes; 4 Hz; 240 G CMP; 25.4 mm amplitude; 1 hour; 22 °C / 55% RH
Samples Tested 3 PCS
Verdict Pass

Document Information

Role Name (Pinyin)
Approval (核准) Mai Shaoqiang
Check / Review (审查) Zhang Ronggui
Tester (试验人) Li Guanghua
Form Number BTK-R-Q-087A/1

Frequently Asked Questions

What test standard was used for the ETENWOLF S4 SUP pump vibration test?

The test followed the ISTA-2A standard, which is a widely recognized protocol for evaluating packaged product performance under transportation simulation conditions including random vibration.

What were the vibration test parameters for the S4 SUP pump?

The S4 was tested in random mode across all three axes (X, Y, Z) for 1 hour at a vibration frequency of 4 Hz, an amplitude of 25.4 mm, and a test speed of 240 G CMP, in a controlled environment of 22 °C and 55% RH.

Did the ETENWOLF S4 SUP pump pass the transportation vibration test?

Yes. All 3 samples passed. After the 1-hour vibration cycle, every unit powered on normally, showed no functional failures, and had no visible appearance abnormalities, resulting in a Pass verdict.

Why is transportation vibration testing important for electric SUP pumps?

Electric SUP pumps contain motors, PCBs, and mechanical seals that can be stressed during shipping. ISTA-2A vibration testing simulates real-world transport conditions to confirm the product arrives at customers in full working order without damage from road or freight vibration.