RoHS Compliance Test Report for ETENWOLF HB3 Air Pump (PUMP5) — Report WTH25X09260772C

Document Overview

Document Overview This page presents the RoHS compliance test report for the ETENWOLF HB3 Air Pump, issued under Report No. WTH25X09260772C by Waltek Testing Group (Shenzhen) Co., Ltd. The report verifies that all tested components comply with the requirements of the EU RoHS Directive 2011/65/EU…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
European Union: CE / RoHS / REACH / WEEE

Document Overview

This page presents the RoHS compliance test report for the ETENWOLF HB3 Air Pump, issued under Report No. WTH25X09260772C by Waltek Testing Group (Shenzhen) Co., Ltd. The report verifies that all tested components comply with the requirements of the EU RoHS Directive 2011/65/EU and its amendment (EU) No. 2015/863, which restricts the use of 10 hazardous substances in electrical and electronic equipment.

Field Details
Document Type RoHS Test Report
Report Number WTH25X09260772C
Issuing Body Waltek Testing Group (Shenzhen) Co., Ltd.
Date of Issue 2025-10-20
Testing Period 2025-09-29 to 2025-10-13
Date of Sample Receipt 2025-09-29
Test Conclusion Pass
Applicable Directive EU RoHS 2011/65/EU and amendment (EU) 2015/863

Product Information

The product submitted for RoHS testing is the ETENWOLF HB3 Air Pump, marketed under the internal model designation PUMP5. The unit is manufactured by Guangdong Bestek Technology Co., Ltd. and is designed as a portable inflation tool for a wide range of applications including tires, sports equipment, and inflatable goods.

Field Details
Sample Name AIR PUMP
Model No. PUMP5
Reference Model No. NA
Brand ETENWOLF HB3
Applicant Guangdong Bestek Technology Co., LTD
Applicant Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R.China
Manufacturer Guangdong Bestek Technology Co., LTD
Manufacturer Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R.China

The product consists of 72 individual tested parts spanning plastics, rubbers, metals, electronic components, PCB assemblies, cables, and battery sub-components, all of which were evaluated for restricted substance content.

Key Details

A total of 72 component parts were sampled and tested from the ETENWOLF HB3 unit. XRF primary screening was applied to all parts, with confirmatory chemical analysis (ICP-OES, UV-Vis, GC-MS) performed where XRF results fell in the indeterminate (IN) range. All results were found to be either Below Limit (BL) or confirmed Negative/Not Detected (ND) upon further chemical testing. A representative selection of tested parts is shown below.

Part No. Part Description Pb Cd Hg Cr (XRF) Br Chemical Result
1 Yellow plastic BL BL BL BL BL NA
2 Black rubber BL BL BL BL BL NA
7 Silvery metal BL BL BL IN NA Cr6+: Negative
8 Silvery metal BL BL BL IN NA Cr6+: Negative
16 Green cladding metal stator BL BL BL IN NA Cr6+: Negative
21 Silvery metal BL BL BL IN NA Cr6+: Negative
40 Silvery metal shell BL BL BL IN NA Cr6+: Negative
43 Silvery square metal (switch) BL BL BL IN NA Cr6+: Negative
56 Black IC SMD BL BL BL BL IN PBBs: ND; PBDEs: ND
58 Green cladding PCB board (whole) BL BL BL BL IN PBBs: ND; PBDEs: ND
66 Silvery metal sheet (battery) BL BL BL BL NA NA
72 Solder BL BL BL BL NA NA

Legend: BL = Below Limit (compliant on XRF screening); IN = Indeterminate (requires chemical confirmation); NA = Not Applicable for that substance/method; ND = Not Detected; Negative = confirmed absent by UV-Vis analysis.

All 72 parts across the full product disassembly returned compliant results for Lead (Pb), Cadmium (Cd), Mercury (Hg), Hexavalent Chromium (Cr6+), Polybrominated Biphenyls (PBBs), Polybrominated Diphenyl Ethers (PBDEs), and all applicable phthalates. No part exceeded any threshold defined under RoHS 2011/65/EU or its amendment (EU) 2015/863.

Standards & Compliance

The testing programme for the ETENWOLF HB3 Air Pump was conducted in full accordance with the following international standards and analytical methods. All standards are published by the International Electrotechnical Commission (IEC).

Standard Scope Analytical Method
IEC 62321-3-1:2013 Screening for Pb, Hg, Cd, total Cr, total Br X-ray Fluorescence Spectrometry (XRF / EDXRF)
IEC 62321-4:2013+AMD1:2017 CSV Mercury (Hg) determination ICP-OES
IEC 62321-5:2013 Lead (Pb) and Cadmium (Cd) determination ICP-OES
IEC 62321-7-2:2017 and/or IEC 62321-7-1:2015 Hexavalent Chromium (Cr6+) determination UV-Vis Spectrophotometry
IEC 62321-6:2015 Polybrominated Biphenyls (PBBs) and Polybrominated Diphenyl Ethers (PBDEs) GC-MS
IEC 62321-8:2017 Phthalates (DEHP, BBP, DBP, DIBP) GC-MS

The applicable regulatory framework is EU RoHS Directive 2011/65/EU as amended by (EU) 2015/863, which expanded the list of restricted substances from 6 to 10 by adding four phthalates: DEHP, BBP, DBP, and DIBP, each with a maximum concentration limit of 0.1% by weight in homogeneous material.

Validity & Certification Body

The test report was issued on 2025-10-20 by Waltek Testing Group (Shenzhen) Co., Ltd., an accredited third-party testing laboratory. The report covers the specific production samples received on 2025-09-29 and tested through 2025-10-13. Validity of the report is contingent on the product design, materials, and supply chain remaining unchanged from the tested samples.

Field Details
Report Number WTH25X09260772C
Date of Issue 2025-10-20
Testing Period 2025-09-29 to 2025-10-13
Date of Sample Receipt 2025-09-29
Laboratory Waltek Testing Group (Shenzhen) Co., Ltd.
Laboratory Address 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70, Bao’an District, Shenzhen, Guangdong, China
Laboratory Website http://www.waltek.com.cn
Contact Tel +86-755-33663308
Contact Fax +86-755-33663309
Contact Email [email protected]
Signatory Hugo Chen, Waltek Testing Group (Shenzhen) Co., Ltd.
Overall Result PASS

This report is applicable to the product model PUMP5 as submitted. Any material changes to components, suppliers, or manufacturing processes would require re-testing to maintain RoHS compliance status.

Frequently Asked Questions

What does it mean that the ETENWOLF HB3 Air Pump passed RoHS testing?

A RoHS Pass result means that all tested components of the ETENWOLF HB3 Air Pump contain restricted hazardous substances — including Lead, Mercury, Cadmium, Hexavalent Chromium, PBBs, PBDEs, and four phthalates — at levels below the maximum concentration thresholds set by EU Directive 2011/65/EU and amendment (EU) 2015/863. This confirms the product is legally compliant for sale in the European Union and other markets that adopt RoHS standards.

Which substances were tested and what are their legal limits under RoHS?

The EU RoHS Directive restricts 10 substances. Lead (Pb), Mercury (Hg), Hexavalent Chromium (Cr6+), PBBs, and PBDEs are each limited to a maximum of 0.1% (1,000 mg/kg) by weight in homogeneous material. Cadmium (Cd) is limited to 0.01% (100 mg/kg). The four phthalates added by amendment (EU) 2015/863 — DEHP, BBP, DBP, and DIBP — are each also limited to 0.1% by weight. All 72 parts of the ETENWOLF HB3 were confirmed below these thresholds.

What test methods were used to verify compliance?

Testing followed a two-stage approach. First, all parts underwent XRF (X-ray fluorescence) screening per IEC 62321-3-1:2013 to rapidly identify any elevated substance concentrations. Parts where XRF returned indeterminate results were then subjected to confirmatory chemical analysis: ICP-OES for Pb, Cd, and Hg; UV-Vis spectrophotometry for Cr6+; and GC-MS for PBBs, PBDEs, and phthalates. All confirmatory results returned Negative or Not Detected.

How long is the RoHS test report valid, and when does re-testing become necessary?

RoHS test reports do not carry a fixed expiry date under the directive itself, but the report WTH25X09260772C is valid as long as the product’s materials, components, and supply chain remain consistent with the tested samples received on 2025-09-29. Re-testing is recommended — and may be legally required — if any material substitution, new supplier, or design change is introduced, as these could alter the hazardous substance profile of the product.

Related Documents

The following certification and compliance document types are relevant for the ETENWOLF HB3 Air Pump and are recommended to be maintained alongside this RoHS test report for complete market access and regulatory coverage:

  • CE Declaration of Conformity — Required for EU market access; covers the full CE marking framework including Low Voltage Directive (LVD) and EMC Directive for electrically powered inflation tools.
  • REACH SVHC Compliance Statement — Addresses Substances of Very High Concern under the EU REACH Regulation (EC) No. 1907/2006, complementing RoHS substance restrictions.
  • UN 38.3 Battery Transport Test Report — Mandatory for products containing lithium-ion batteries; certifies safe transport per UN 38.3 requirements.
  • FCC Declaration of Conformity — Required for the US market; covers electromagnetic emissions compliance for electronic devices under FCC Part 15 regulations.
  • KC Certification — Required for the South Korean market; covers electrical safety and EMC standards administered by the Korea Agency for Technology and Standards.
  • ISO 9001 Quality Management Certification — Documents the manufacturer’s quality management system, supporting confidence in consistent production standards for the ETENWOLF HB3 product line.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21