CE EMC Test Report WTH25H05129161E — ETENWOLF Air3 Portable Air Pump

Document Overview

Document Overview This article covers the official CE/EMC test report issued for the ETENWOLF Air3 portable air pump. The report was prepared by Waltek Testing Group HCT (Shenzhen) Co., Ltd. under reference number WTH25H05129161E and test report form number TRF EN IEC 55014-1: 2021-EMC-001-V01 (internal…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
European Union: CE / RoHS / REACH / WEEE

Document Overview

This article covers the official CE/EMC test report issued for the ETENWOLF Air3 portable air pump. The report was prepared by Waltek Testing Group HCT (Shenzhen) Co., Ltd. under reference number WTH25H05129161E and test report form number TRF EN IEC 55014-1: 2021-EMC-001-V01 (internal form code HCT/RF-23-21).

  • Document Type: CE/CE-EMC Test Report
  • Issuing Laboratory: Waltek Testing Group HCT (Shenzhen) Co., Ltd., Building B, Tianji Industrial Park, 1/F. & 2/F. & 3/F., No.30-9, Laiyin Road, Xinsheng Community, Longgang Subdistrict, Longgang District, Shenzhen, Guangdong, China
  • Reference Number: WTH25H05129161E
  • Date of Sample Receipt: 2025-05-27
  • Test Period: 2025-05-27 to 2025-05-29
  • Date of Issue: 2025-06-04
  • Overall Test Result: Pass

The report covers electromagnetic compatibility (EMC) evaluations including conducted disturbance at mains terminals, disturbance power in the frequency range, and radiated disturbances, confirming compliance with applicable CE marking requirements for the European market.

Product Information

The equipment under test (EUT) is the ETENWOLF Air3, a compact and portable air pump designed for inflating tyres, sports equipment, and other inflatable items.

  • Product Name: Portable Air Pump
  • Model Number: Air3
  • Brand: ETENWOLF
  • Applicant: Guangdong Bestek Technology Co., Ltd.
  • Applicant Address: No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China
  • Manufacturer: Guangdong Bestek Technology Co., Ltd.
  • Manufacturer Address: No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China

The Air3 is a battery-powered portable inflation tool. As a motor-driven device intended for consumer and professional use, it is subject to CE marking under the EMC Directive, requiring demonstration that it does not generate excessive electromagnetic interference and maintains adequate immunity during operation.

Key Details

The table below summarises the key test parameters and results documented in report WTH25H05129161E.

Parameter Detail
Reference Number WTH25H05129161E
Test Report Form No. TRF EN IEC 55014-1: 2021-EMC-001-V01
Internal Form Code HCT/RF-23-21
Product Model Air3
Product Category Portable Air Pump (Motor-Driven Tool)
Date of Sample Receipt 2025-05-27
Test Start Date 2025-05-27
Test End Date 2025-05-29
Date of Issue 2025-06-04
Conducted Disturbance — Mains Terminals Tested per EN IEC 55014-1:2021 — Pass
Disturbance Power in Frequency Range Tested per EN IEC 55014-1:2021 — Pass
Radiated Disturbances Tested per EN IEC 55014-1:2021 — Pass
Harmonics Current Emissions Tested per EN IEC 61000-3-2:2019+A1:2021 — Pass
Voltage Fluctuations & Flicker Tested per EN 61000-3-3:2013+A2:2021 — Pass
Immunity Requirements Tested per EN IEC 55014-2:2021 — Pass
Overall Result Pass
Prepared By Snow Zeng
Approved By Tony Wu

The test scope encompassed all major EMC emission and immunity categories required for CE marking of household and similar electrical motor-operated tools, consistent with the product classification under the relevant EU directives.

Standards & Compliance

The ETENWOLF Air3 was evaluated against the following harmonised European standards. Compliance with these standards supports the CE marking declaration of conformity.

  • EN IEC 55014-1:2021 — Electromagnetic disturbances from household appliances, electric tools and similar apparatus. Part 1: Emission. This standard specifies limits and measurement methods for conducted and radiated disturbances in the frequency range 9 kHz to 400 GHz for motor-operated and thermal appliances.
  • EN IEC 55014-2:2021 — Electromagnetic disturbances from household appliances, electric tools and similar apparatus. Part 2: Immunity. This standard defines immunity requirements ensuring the product functions correctly in the presence of electromagnetic disturbances.
  • EN IEC 61000-3-2:2019+A1:2021 — Limits for harmonic current emissions (equipment input current up to and including 16 A per phase). This standard limits the harmonic currents injected into the public supply network.
  • EN 61000-3-3:2013+A2:2021 — Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current up to and including 16 A per phase.

Testing covered three primary EMC measurement categories: conducted disturbance at mains terminals, disturbance power in the frequency range, and radiated disturbances. All measurements were performed with the EUT operating under representative load conditions and using calibrated test equipment traceable to national standards.

Validity & Certification Body

The test report WTH25H05129161E was issued on 2025-06-04 by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited EMC and safety testing laboratory.

  • Issuing Laboratory: Waltek Testing Group HCT (Shenzhen) Co., Ltd.
  • Laboratory Website: http://www.hct-test.com
  • Laboratory Address: Building B, Tianji Industrial Park, 1/F. & 2/F. & 3/F., No.30-9, Laiyin Road, Xinsheng Community, Longgang Subdistrict, Longgang District, Shenzhen, Guangdong, China
  • Telephone: 0755-84616666
  • Service Hotline: 400-0066-989
  • Email: [email protected]
  • Report Prepared By: Snow Zeng
  • Report Approved By: Tony Wu
  • Date of Issue: 2025-06-04

CE/EMC test reports of this type support the manufacturer’s Declaration of Conformity (DoC) for CE marking purposes. The report remains valid as long as the product design, components, and intended use remain unchanged from the tested configuration. Any modification to the EUT may require re-testing. This report covers 51 pages in total as documented in the original filing.

Frequently Asked Questions

What does the CE EMC test report WTH25H05129161E confirm for the Air3?
Report WTH25H05129161E confirms that the ETENWOLF Air3 portable air pump passed all required electromagnetic compatibility (EMC) tests for CE marking, including conducted disturbance, radiated disturbance, harmonic current emissions, and voltage flicker, tested against EN IEC 55014-1:2021, EN IEC 55014-2:2021, EN IEC 61000-3-2:2019+A1:2021, and EN 61000-3-3:2013+A2:2021.
Which laboratory conducted the CE EMC testing for the Air3?
The testing was performed by Waltek Testing Group HCT (Shenzhen) Co., Ltd., located in Longgang District, Shenzhen, Guangdong, China. The report was prepared by Snow Zeng and approved by Tony Wu, and issued on 2025-06-04.
Does the Air3 comply with the EU EMC Directive based on this report?
Yes. The Pass result across all test categories in report WTH25H05129161E supports the manufacturer’s Declaration of Conformity under the EU EMC Directive (2014/30/EU), allowing the Air3 to carry the CE mark for sale in the European Economic Area.
What happens if the Air3 design is modified after this report was issued?
If the product design, internal components, firmware, or intended use of the ETENWOLF Air3 changes after the test date of 2025-05-27 to 2025-05-29, re-testing may be required to maintain the validity of the CE EMC compliance documentation. The report is specific to the tested configuration.

Related Documents

The following certification and compliance document types are typically required alongside a CE/EMC test report for a portable air pump such as the ETENWOLF Air3:

  • CE LVD (Low Voltage Directive) Test Report — Required if the product operates at mains voltage levels; covers electrical safety under Directive 2014/35/EU and relevant EN standards such as EN 62368-1 or EN 60335 series.
  • CE Declaration of Conformity (DoC) — The manufacturer’s signed declaration referencing all applicable directives and harmonised standards, required to legally affix the CE mark.
  • UN 38.3 Battery Test Report — Required for the lithium-ion or lithium polymer battery pack inside the Air3 for safe transport classification under UN Recommendations on the Transport of Dangerous Goods.
  • RoHS Compliance Report — Confirms restriction of hazardous substances (lead, mercury, cadmium, etc.) under EU Directive 2011/65/EU.
  • REACH SVHC Declaration — Declares compliance with REACH Regulation (EC) No 1907/2006 regarding substances of very high concern.
  • FCC Test Report — Required for market access in the United States, covering unintentional radiator requirements under FCC Part 15.
  • KC Certification (KC Mark) — Required for the South Korean market, covering both safety and EMC requirements under Korean standards.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22
Document Page 23
Document Page 24
Document Page 25
Document Page 26
Document Page 27
Document Page 28
Document Page 29
Document Page 30
Document Page 31
Document Page 32
Document Page 33
Document Page 34
Document Page 35
Document Page 36
Document Page 37
Document Page 38
Document Page 39
Document Page 40
Document Page 41
Document Page 42
Document Page 43
Document Page 44
Document Page 45
Document Page 46
Document Page 47
Document Page 48
Document Page 49
Document Page 50
Document Page 51