CE-LVD Test Report for ETENWOLF C2PRO Wireless Portable Tire Pump – WTH25X11289148J

Document Overview

Document Overview This article covers the official CE Low Voltage Directive (LVD) test report issued for the ETENWOLF C2PRO Wireless Portable Tire Pump. The document is classified as a full safety test report prepared by Waltek Testing Group (Shenzhen) Co., Ltd., an accredited third-party testing…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
European Union: CE / RoHS / REACH / WEEE

Document Overview

This article covers the official CE Low Voltage Directive (LVD) test report issued for the ETENWOLF C2PRO Wireless Portable Tire Pump. The document is classified as a full safety test report prepared by Waltek Testing Group (Shenzhen) Co., Ltd., an accredited third-party testing laboratory located at 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70, Bao’an District, Shenzhen, Guangdong, China.

  • Reference Number: WTH25X11289148J
  • Document Type: CE-LVD Safety Test Report
  • Test Report Form No.: WTX_EN IEC 60335_1_2023B
  • Date of Sample Receipt: 2025-11-05
  • Test Period: 2025-11-05 to 2025-11-13
  • Date of Issue: 2025-11-17
  • Overall Test Result: Pass

The report scope covers household and similar electrical appliance safety requirements, as well as electromagnetic field measurement methods relevant to human exposure. It applies exclusively to the sample(s) submitted for testing and may not be reproduced in part without prior written permission from the issuing laboratory.

Product Information

The product evaluated in this report is the ETENWOLF C2PRO, a compact and cordless inflation solution engineered for consumer and household use.

Field Details
Product Name Wireless Portable Tire Pump
Model Number C2pro
Trademark ETENWOLF
Rated Input 5 V, 2.0 A
Equipment Class Class III (Safety Extra-Low Voltage)
Supply Connection DC Connector
Installation & Use Classification Hand-held appliance, indoor use only
Ingress Protection IPX0 (no water ingress protection rated)
Intended Application Household and indoor use only
Country of Manufacture China

The applicant and manufacturer for this report is Guangdong Bestek Technology Co., Ltd., located at No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China. The factory address is the same as the manufacturer address.

The product label must include, at minimum: rated input voltage and current, manufacturer name and address, importer name and address (when placed on the EU market), model reference, CE mark (minimum height 5 mm), and WEEE mark (minimum height 7 mm).

Key Details

The following table summarises the primary test clauses evaluated under EN IEC 60335-1:2023+A11:2023 and the corresponding verdicts recorded by Waltek Testing Group.

Clause Requirement / Test Area Verdict
Clause 5 General Conditions for the Tests (nature of supply, sequence of testing) Pass
Clause 6 – 6.1 Classification – Protection against electric shock: Class III Pass
Clause 6 – 6.2 Protection against harmful ingress of water – IPX0 N/A
Clause 7 – 7.1 Marking: Rated voltage, current, manufacturer identification, model reference Pass
Clause 7 – 7.1 Symbol IEC 60417-5180 for Class III (battery-operated exemption applied) Pass
Clause 7 – 7.1 Appliances intended to be supplied from a detachable power supply part to recharge the battery Pass
Clause 7 – 7.2 Warning for stationary appliances for multiple supply N/A
Clause 7 – 7.3 Range of rated values marking requirements N/A

Test verdict key used throughout the report:

  • P (Pass) — Test object meets the requirement
  • F (Fail) — Test object does not meet the requirement
  • N/A (Not Applicable) — Test case does not apply to this product

No subcontracting of test items to external laboratories was required for this evaluation. All testing was conducted entirely at the Waltek Testing Group Shenzhen facility.

Standards & Compliance

The ETENWOLF C2PRO was evaluated against the following applicable European harmonised standards, confirming conformity with the CE Low Voltage Directive requirements:

Standard Title Scope Relevance
EN IEC 60335-1:2023+A11:2023 Household and similar electrical appliances – Safety – Part 1: General requirements Primary safety standard covering electrical, mechanical, thermal, and marking requirements for household appliances
EN 62233:2008 Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure EMF measurement methodology ensuring safe human exposure levels during normal product operation

The product is classified as Class III equipment, meaning it operates at Safety Extra-Low Voltage (SELV) supplied via a DC connector rated at 5 V / 2.0 A. This classification exempts certain high-voltage marking requirements while still mandating full compliance with general safety and EMF exposure clauses. The submitted samples were found to comply with all applicable requirements of the above specifications.

Validity & Certification Body

The test report bearing reference number WTH25X11289148J was issued on 2025-11-17 and remains valid for the product configuration and samples tested. Any modifications to the product design, components, or rated parameters would require re-evaluation.

Field Details
Issuing Laboratory Waltek Testing Group (Shenzhen) Co., Ltd.
Laboratory Address 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70, Bao’an District, Shenzhen, Guangdong, China
Laboratory Website http://www.waltek.com.cn
Telephone +86-755-33663308
Fax +86-755-33663309
Email [email protected]
Prepared By John Zhong, Project Engineer
Approved By Harvid Wei, Manager
Report Total Pages 128 pages
Date of Issue 2025-11-17

This report is valid only when accompanied by the specific stamp of the issuing test institute and the original signatures of the approver. Partial reproduction is not permitted without prior written consent from Waltek Testing Group.

Frequently Asked Questions

What does the CE-LVD certification mean for the C2PRO tire pump?

CE-LVD (Low Voltage Directive) certification confirms that the ETENWOLF C2PRO meets the European Union’s safety requirements for electrical equipment operating at low voltage. It demonstrates that the product has been independently tested against EN IEC 60335-1:2023+A11:2023 and passed all applicable safety and EMF exposure checks, making it legally compliant for sale across EU member states.

Who conducted the CE-LVD testing for the C2PRO, and is the lab accredited?

The testing was conducted by Waltek Testing Group (Shenzhen) Co., Ltd., a recognised third-party testing and certification laboratory based in Shenzhen, China. The laboratory issued report number WTH25X11289148J, dated 2025-11-17, covering 128 pages of detailed test results and clause-by-clause compliance assessments.

What is the rated input for the C2PRO and why is it classified as Class III?

The C2PRO operates at a rated input of 5 V / 2.0 A supplied via a DC connector. Class III classification applies to appliances that operate at Safety Extra-Low Voltage (SELV), which poses a lower risk of electric shock. This classification is consistent with battery-powered or USB-charged portable devices and drives specific marking and construction requirements under EN IEC 60335-1.

Can this test report be used to support CE marking on product packaging and documentation?

Yes. This test report forms part of the technical file required to support the CE Declaration of Conformity for the ETENWOLF C2PRO. However, the report must be reproduced in full and must bear the original laboratory stamp and approver signature to be valid. When the product is placed on the EU market, the product label must also include the importer’s name and address alongside the manufacturer details.

Related Documents

For a complete compliance and regulatory documentation package for the ETENWOLF C2PRO, the following related certification and test report types are recommended:

  • CE-EMC Test Report — Electromagnetic Compatibility testing under EN 55014-1 and EN 55014-2, required alongside LVD for full CE marking of household appliances.
  • CE Declaration of Conformity (DoC) — The formal manufacturer declaration referencing this LVD report and all applicable EU directives.
  • UN 38.3 Battery Safety Report — Required for lithium battery transport compliance, applicable given the C2PRO’s rechargeable battery design.
  • RoHS Compliance Report — Confirming restriction of hazardous substances under EU RoHS Directive 2011/65/EU.
  • REACH SVHC Declaration — Substance of Very High Concern assessment under REACH Regulation (EC) No 1907/2006.
  • FCC ID / SDOC Report — Required for sale in the United States market, covering radio frequency and unintentional radiation standards.
  • KC Certification — Korea Certification mark required for the South Korean market under the KC Safety Act.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22
Document Page 23
Document Page 24
Document Page 25
Document Page 26
Document Page 27
Document Page 28
Document Page 29
Document Page 30
Document Page 31
Document Page 32
Document Page 33
Document Page 34
Document Page 35
Document Page 36
Document Page 37
Document Page 38
Document Page 39
Document Page 40
Document Page 41
Document Page 42
Document Page 43
Document Page 44
Document Page 45
Document Page 46
Document Page 47
Document Page 48
Document Page 49
Document Page 50
Document Page 51
Document Page 52
Document Page 53
Document Page 54
Document Page 55
Document Page 56
Document Page 57
Document Page 58
Document Page 59
Document Page 60
Document Page 61
Document Page 62
Document Page 63
Document Page 64
Document Page 65
Document Page 66
Document Page 67
Document Page 68
Document Page 69
Document Page 70
Document Page 71
Document Page 72
Document Page 73
Document Page 74
Document Page 75
Document Page 76
Document Page 77
Document Page 78
Document Page 79
Document Page 80
Document Page 81
Document Page 82
Document Page 83
Document Page 84
Document Page 85
Document Page 86
Document Page 87
Document Page 88
Document Page 89
Document Page 90
Document Page 91
Document Page 92
Document Page 93
Document Page 94
Document Page 95
Document Page 96
Document Page 97
Document Page 98
Document Page 99
Document Page 100
Document Page 101
Document Page 102
Document Page 103
Document Page 104
Document Page 105
Document Page 106
Document Page 107
Document Page 108
Document Page 109
Document Page 110
Document Page 111
Document Page 112
Document Page 113
Document Page 114
Document Page 115
Document Page 116
Document Page 117
Document Page 118
Document Page 119
Document Page 120
Document Page 121
Document Page 122
Document Page 123
Document Page 124
Document Page 125
Document Page 126
Document Page 127
Document Page 128