ETENWOLF Air3 Hair Dryer High/Low Temperature Storage Test Report (72 h, 60 °C / −20 °C)

Document Overview

Key Findings The ETENWOLF Air3 hair dryer successfully passed a 72-hour high/low temperature storage test with no appearance anomalies and all button functions operating normally after exposure to extreme thermal conditions. Product: TB1 (Air3 hair dryer) Manufacturer: BTK Sample Quantity: 3 pcs High-Temperature Condition: 60…

Document type
Test Report
Prepared by
Alex Newman
Published
Last reviewed
Topics
Environmental Testing

Key Findings

The ETENWOLF Air3 hair dryer successfully passed a 72-hour high/low temperature storage test with no appearance anomalies and all button functions operating normally after exposure to extreme thermal conditions.

  • Product: TB1 (Air3 hair dryer)
  • Manufacturer: BTK
  • Sample Quantity: 3 pcs
  • High-Temperature Condition: 60 °C, 80% RH, 4 hours
  • Low-Temperature Condition: −20 °C, 4 hours
  • Total Storage Duration: 72 hours
  • Test Dates: 2025-03-08 to 2025-03-11
  • Overall Verdict: Pass

Test Overview

Field Details
Test Type High/Low Temperature Storage Test
Report Number 2025031101
Page 1
Test Dates 2025-03-08 to 2025-03-11
Product Name TB1 (Air3 Hair Dryer)
Manufacturer BTK
Surface Treatment /
Sample Quantity 3 pcs
Test Reason New product qualification
Test Purpose Evaluate the durability of the prototype unit when stored in extreme temperature environments
Laboratory Temperature 24 °C
Laboratory Humidity 45% RH

Test Equipment & Setup

Item Details
Instrument Constant Temperature and Humidity Testing Machine
Test Class / Level
Condition 1 — High Temperature 60 °C, Humidity 80% RH, Duration 4 hours
Condition 2 — Low Temperature −20 °C, Duration 4 hours
Total Storage Duration 72 hours
Post-Storage Functional Test Required
Acceptance Requirement No functional abnormalities after testing

Test Procedure

  1. Pre-test preparation: Record laboratory ambient conditions (temperature 24 °C, humidity 45% RH). Confirm 3 sample units are in normal operating condition. Document report number 2025031101.
  2. High-temperature phase: Place samples in the constant temperature and humidity testing machine. Set chamber to 60 °C and 80% RH. Maintain for 4 hours.
  3. Low-temperature phase: Adjust chamber to −20 °C (no humidity control required). Maintain for 4 hours.
  4. Extended storage: Continue cycling/storage in the chamber for a total cumulative storage duration of 72 hours as programmed in the controller profile.
  5. Post-test functional verification: Remove samples from chamber. Allow units to return to ambient conditions. Power on each unit and verify normal startup. Test all button functions. Verify airflow pressure (wind pressure) is within normal range.
  6. Acceptance criteria: No appearance anomalies; all button functions normal; wind pressure OK. Any failure on any sample constitutes a Fail verdict.

Test Data & Results

Check Item Requirement Observation After 72 h Storage Result
Unit Power-On Normal startup after test All 3 samples powered on normally Pass
Button Functions All buttons functional All button functions normal on all samples Pass
Appearance / Exterior No anomalies No appearance anomalies observed Pass
Wind Pressure (Airflow) Normal / OK Wind pressure OK Pass

Summary observation (translated from report): After 72 hours of high/low temperature storage testing, the sample exterior showed no anomalies, all button functions were normal, and wind pressure was OK. The unit could power on normally after the test; all button functions performed correctly per the program control profile.

Conclusion

Field Details
Result Statement After 72-hour high/low temperature storage, sample appearance showed no anomalies, all button functions were normal, and wind pressure was OK.
High-Temperature Condition 60 °C, 80% RH, 4 hours
Low-Temperature Condition −20 °C, 4 hours
Total Storage 72 hours
Samples Tested 3 pcs
Judgment Pass (■ 合格)

Document Information

Role Name (Pinyin)
Approval (核准)
Review / Check (审查) Mai Shaoqiang
Tester (试验人) Zhang Ronggui
Form Number (表单编号) BTK-R-Q-087A/1

Frequently Asked Questions

What temperature conditions were used in the ETENWOLF Air3 high/low temperature storage test?

The Air3 was tested at 60 °C with 80% relative humidity for 4 hours (high-temperature phase) and at −20 °C for 4 hours (low-temperature phase), with a total cumulative storage duration of 72 hours inside a constant temperature and humidity chamber.

Did the ETENWOLF Air3 pass the high/low temperature storage test?

Yes. All 3 sample units passed. After 72 hours of high/low temperature storage, the Air3 showed no appearance anomalies, all button functions operated normally, and airflow pressure was confirmed OK.

What equipment was used to conduct the Air3 temperature storage test?

A constant temperature and humidity testing machine was used. The laboratory ambient conditions during the test were 24 °C and 45% RH. The test was conducted from 2025-03-08 to 2025-03-11 at BTK’s facility.

How many samples of the Air3 were tested in the high/low temperature storage test?

Three (3) samples were tested. All three units demonstrated normal power-on behavior, normal button functionality, and acceptable wind pressure after the full 72-hour storage cycle.

Related Products