RoHS Compliance Test Report – ETENWOLF V3 Air Inflator (Report No. WTH25X05129148C)

Document Overview

Document Overview This page presents the official RoHS test report issued for the ETENWOLF V3 Air Inflator. The report was prepared by Waltek Testing Group (Shenzhen) Co., Ltd., an accredited third-party testing laboratory, and carries Report Number WTH25X05129148C. The test was conducted in accordance with…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
European Union: CE / RoHS / REACH / WEEE

Document Overview

This page presents the official RoHS test report issued for the ETENWOLF V3 Air Inflator. The report was prepared by Waltek Testing Group (Shenzhen) Co., Ltd., an accredited third-party testing laboratory, and carries Report Number WTH25X05129148C.

The test was conducted in accordance with the EU RoHS Directive 2011/65/EU and its amending regulation (EU) 2015/863, which restricts the use of 10 hazardous substances in electrical and electronic equipment placed on the European market.

  • Report Number: WTH25X05129148C
  • Document Type: RoHS Test Report
  • Issuing Body: Waltek Testing Group (Shenzhen) Co., Ltd.
  • Date of Issue: 2025-06-17
  • Test Conclusion: PASS
  • Applicable Directive: EU RoHS Directive 2011/65/EU and amendment (EU) 2015/863
  • Scope: Determination of 10 restricted hazardous substances in all submitted sample components

Product Information

The tested product is the V3 Air Inflator, an electric portable inflation tool manufactured by Guangdong Bestek Technology Co., LTD and distributed under the ETENWOLF brand. The product is designed for inflating tires, sports equipment, and other inflatable items.

Field Details
Sample Name Air Inflator
Model Number V3
Reference Model NA
Brand NA (distributed by ETENWOLF)
Applicant Guangdong Bestek Technology Co., LTD
Manufacturer Guangdong Bestek Technology Co., LTD
Manufacturer Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China
Date of Sample Receipt 2025-05-23 & 2025-06-10 & 2025-06-13
Testing Period 2025-05-23 ~ 2025-06-04 & 2025-06-10 ~ 2025-06-12 & 2025-06-13 ~ 2025-06-15

Key Details

The V3 Air Inflator was disassembled into 84 individual component parts, each tested for the presence of RoHS-restricted substances. All components returned results below detection limits (BL) or were confirmed as Not Detected (ND) through follow-up chemical analysis where flagged as Inconclusive (IN) by XRF screening. The overall test conclusion is PASS.

Below is a representative summary of tested parts and their results for the primary restricted substances: Lead (Pb), Cadmium (Cd), Mercury (Hg), Total Chromium (Cr), and Bromine (Br) via XRF, with chemical confirmation where required.

Part No. Part Description XRF Result Chemical Confirmation
1 Orange plastic shell All BL NA
5–10 Black rubber / Black rubber ring All BL NA
14 Silvery metal spring Cr: IN Cr6+: Negative
17 Black cladding metal screw Cr: IN Cr6+: ND
24 Dark metal gear Cr: IN Cr6+: Negative
25 Silvery metal axle Cr: IN Cr6+: Negative
40 Silvery metal cover Cr: IN Cr6+: Negative
50 Black cladding PCB board Br: IN PBBs: ND / PBDEs: ND
62 Silvery square metal body (switch) Cr: IN Cr6+: Negative
64 Black cladding PCB board (whole) Br: IN PBBs: ND / PBDEs: ND
74 Green cladding PCB board (whole) All BL NA
79 Gray solid material body (Inductance) Cr: IN Cr6+: ND

In every case where XRF screening produced an Inconclusive (IN) result, follow-up chemical analysis confirmed no hexavalent chromium (Cr6+), no polybrominated biphenyls (PBBs), and no polybrominated diphenyl ethers (PBDEs) in excess of permissible limits. All remaining parts tested Below Limit (BL) for all restricted substances.

Standards & Compliance

The testing program applied a suite of internationally recognised IEC test methods to characterise each restricted substance category. The following standards were used:

Standard Scope Analytical Method
IEC 62321-3-1:2013 Screening – Pb, Hg, Cd, total Cr, total Br X-Ray Fluorescence Spectrometry (XRF)
IEC 62321-4:2013+AMD1:2017 CSV Mercury (Hg) ICP-OES
IEC 62321-5:2013 Lead (Pb) and Cadmium (Cd) ICP-OES
IEC 62321-7-2:2017 and/or IEC 62321-7-1:2015 Hexavalent Chromium (Cr6+) UV-Vis Spectrophotometry
IEC 62321-6:2015 PBBs and PBDEs GC-MS
IEC 62321-8:2017 Phthalates (DEHP, BBP, DBP, DIBP) GC-MS

The applicable regulatory framework is the EU RoHS Directive 2011/65/EU, as amended by (EU) 2015/863, which extended restricted phthalates (DEHP, BBP, DBP, DIBP) to the full list of 10 restricted substances effective July 2019 for most product categories.

Validity & Certification Body

The test report was issued on 2025-06-17 by Waltek Testing Group (Shenzhen) Co., Ltd., a globally recognised third-party testing, inspection, and certification laboratory. RoHS test reports of this type are valid as long as the product design, materials, and supply chain remain unchanged. Any material substitution or design revision would require re-testing to maintain compliance status.

Field Details
Laboratory Waltek Testing Group (Shenzhen) Co., Ltd.
Laboratory Address 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70 Bao’an District, Shenzhen, Guangdong, China
Laboratory Website http://www.waltek.com.cn
Telephone +86-755-33663308
Fax +86-755-33663309
Email [email protected]
Report Signed By Hugo Chen
Date of Issue 2025-06-17
Report Number WTH25X05129148C
Validity Note Valid while product materials and design remain unchanged

Frequently Asked Questions

Q: What does the RoHS PASS result mean for the V3 Air Inflator?

A PASS result means that all 84 tested components of the V3 Air Inflator contain restricted hazardous substances — including lead, mercury, cadmium, hexavalent chromium, PBBs, PBDEs, and the four phthalates — at levels below the maximum concentration limits set by EU RoHS Directive 2011/65/EU and its amendment (EU) 2015/863. The product is legally compliant for sale in the European Union and other RoHS-adopting markets.

Q: Which hazardous substances were tested under this report?

The report covers the 10 substances restricted under the amended EU RoHS Directive: Lead (Pb), Mercury (Hg), Cadmium (Cd), Hexavalent Chromium (Cr6+), Polybrominated Biphenyls (PBBs), Polybrominated Diphenyl Ethers (PBDEs), and four phthalates — DEHP, BBP, DBP, and DIBP. Each substance was tested using internationally recognised IEC 62321-series methods.

Q: Why were some components flagged as Inconclusive (IN) in XRF screening?

XRF screening is a non-destructive primary screening technique. When a result is Inconclusive (IN) — typically due to chromium or bromine readings near detection thresholds — the laboratory performs confirmatory chemical analysis. For every IN result in this report, follow-up testing confirmed either Negative or Not Detected (ND) for the relevant restricted substance. All IN flags were resolved as compliant.

Q: Is this RoHS report sufficient for CE marking of the V3 Air Inflator?

RoHS compliance is one component of the CE marking requirements. This report, issued by accredited laboratory Waltek Testing Group, demonstrates conformity with the RoHS Directive 2011/65/EU for the V3 Air Inflator. CE marking may additionally require conformity assessments under other applicable directives such as the Low Voltage Directive or the Machinery Directive depending on the product’s full specification and intended market. Consult your regulatory advisor for complete CE marking documentation requirements.

Related Documents

For a complete compliance picture of the V3 Air Inflator, the following related certification and test documents are typically required or recommended alongside this RoHS report:

  • REACH SVHC Declaration — Confirms absence of Substances of Very High Concern under EU REACH Regulation (EC) No. 1907/2006, complementary to RoHS for chemical safety.
  • CE Declaration of Conformity — Manufacturer’s formal declaration covering all applicable EU directives for placing the product on the EU market.
  • FCC / IC Radio Frequency Report — Required for North American markets if the product includes wireless communication or emits RF energy. See FCC requirements.
  • UN 38.3 Battery Safety Test Report — If the V3 Air Inflator includes a lithium battery, a UN 38.3 transport safety test report is required for air and sea freight.
  • KC Certification (Korea) — Required for import and sale of electrical products in the Republic of Korea under the KC mark framework.
  • IEC 62133 / UL Battery Safety Report — Covers electrochemical safety of rechargeable battery cells and packs if applicable to the product configuration.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22
Document Page 23