ETENWOLF HB1 Air Pump High/Low Temperature Storage Cycle Test Report (60°C / −20°C, 72 h)

Document Overview

Key Findings The HB1 air pump (HB1-吹气泵) successfully passed the high/low temperature storage cycle test, showing no appearance anomalies or functional failures after exposure to extreme temperature conditions. Test Type: High/Low Temperature Storage Cycling (高低温存储测试) Report No.: 2025072801 Test Dates: 2025-07-25 to 2025-07-28 Product: HB1…

Document type
Test Report
Prepared by
Alex Newman
Published
Last reviewed
Topics
Environmental Testing

Key Findings

The HB1 air pump (HB1-吹气泵) successfully passed the high/low temperature storage cycle test, showing no appearance anomalies or functional failures after exposure to extreme temperature conditions.

  • Test Type: High/Low Temperature Storage Cycling (高低温存储测试)
  • Report No.: 2025072801
  • Test Dates: 2025-07-25 to 2025-07-28
  • Product: HB1 Air Pump (HB1-吹气泵)
  • Manufacturer: BTK
  • Sample Quantity: 3 pcs
  • High Temperature Condition: 60°C, 80% RH, 2 hours
  • Low Temperature Condition: −20°C, 2 hours
  • Total Storage Duration: 72 hours
  • Verdict: PASS — no appearance defects, no functional failure, normal power-on and charging after test

Test Overview

Field Details
Test Type Environmental Testing — High/Low Temperature Storage Cycle (高低温存储测试)
Standard / Sheet 高低温 (Sheet Index 1 of 1)
Report No. 2025072801
Page 1
Test Dates 2025-07-25 to 2025-07-28
Product HB1 Air Pump (HB1-吹气泵)
Manufacturer BTK
Surface Treatment /
Sample Quantity 3 pcs
Test Reason New Product (■ New Product; Engineering Change Notice — No; Regular Verification — No; Quality Abnormal — No; Other — No)
Test Purpose Evaluate the durability of the prototype during storage under extreme temperature environments
Laboratory Environment Temperature: 24°C; Humidity: 45% RH
Test Class / Level
Product Line Inflation Tools
Category Air Pump / Blower Class (吹风机类)

Test Equipment & Setup

Item Parameter Value
Instrument Name Constant Temperature and Humidity Testing Machine (恒温恒湿试验机)
Test Condition 2.1 High Temperature 60°C, Humidity 80% RH, Duration 2 hours
Test Condition 2.2 Low Temperature −20°C, Duration 2 hours
Test Condition 2.3 Total Storage Duration 72 hours
Test Condition 2.4 Post-Test Functional Check Functional test required
Test Requirement Objective Verify stability under extreme environmental conditions

Test Procedure

  1. Pre-Test: Record laboratory ambient conditions (Temperature: 24°C, Humidity: 45% RH). Inspect and document sample appearance for 3 pcs of HB1 air pump. Photograph samples before testing (程序控制图 / pre-test images captured).
  2. High Temperature Phase: Place samples in the constant temperature and humidity testing machine. Set chamber to 60°C and 80% RH. Maintain for 2 hours.
  3. Low Temperature Phase: Transition chamber to −20°C. Maintain for 2 hours.
  4. Cycle Continuation: Repeat high/low temperature cycles as required to complete a total cumulative storage duration of 72 hours.
  5. Post-Test Functional Check (2.4): Remove samples from chamber. Allow samples to return to ambient conditions. Power on each sample and verify normal operation. Verify charging function operates normally.
  6. Post-Test Appearance Inspection: Examine all 3 samples for any physical deformation, cracking, discoloration, or surface anomalies.
  7. Acceptance Criteria: No appearance abnormalities. All functional checks (power-on, charging) pass. Verdict recorded as Pass (合格), Fail (不合格), or Reference (参考).

Test Data & Results

Check Item Condition Requirement Result / Observation
Pre-Test Appearance Ambient (24°C, 45% RH) No defects Normal — images captured (测试前程序控制图)
High Temperature Exposure 60°C, 80% RH, 2 hours No deformation, no failure Completed
Low Temperature Exposure −20°C, 2 hours No cracking, no failure Completed
Total Storage Duration Cumulative cycling 72 hours Completed
Post-Test Power-On Ambient recovery Normal start-up PASS — 开机正常 (Power-on normal)
Post-Test Charging Ambient recovery Charging functions correctly PASS — 充电正常 (Charging normal)
Post-Test Appearance Ambient recovery No appearance anomalies PASS — No anomalies observed
Overall Functional Test Post-cycle No functional failure PASS — 功能无失效

Observations: All 3 samples of the HB1 air pump passed the extreme environment cyclic temperature/humidity shock test. Post-test inspection confirmed no appearance abnormalities (外观无异常) and no functional failures (功能无失效). Both power-on and charging operations were confirmed normal after the test cycle.

Conclusion

Field Details
Result ■ Pass (合格Pass)
Fail / Reference Fail — No; Reference — No
Test Standard / Conditions High Temp: 60°C / 80% RH / 2 h; Low Temp: −20°C / 2 h; Total storage: 72 h
Samples Tested 3 pcs — HB1 Air Pump (HB1-吹气泵), Manufacturer: BTK
Appearance Verdict No abnormalities detected
Functional Verdict No failures — power-on normal, charging normal
Overall Verdict PASS

Document Information

Role Name (Pinyin)
Approval (核准) Mai Shaoqiang
Review / Check (审查) Zhang Ronggui
Tester (试验人) Li Guanghua
Form Number (表单编号) BTK-R-Q-087A/1
Report No. 2025072801
Page 1

Frequently Asked Questions

What is a high/low temperature storage cycle test?

A high/low temperature storage cycle test exposes a product to alternating extremes of heat and cold while in a non-operating (stored) state. The purpose is to evaluate whether materials, joints, and components can withstand thermal expansion and contraction without cracking, deforming, or losing function. In this test, the HB1 was subjected to 60°C at 80% RH and −20°C in repeated cycles over a total of 72 hours.

Why is the total storage duration set to 72 hours?

72 hours is a commonly used benchmark in consumer electronics environmental testing because it provides sufficient time to stress-test material bonds, plastic housings, and internal electronics across multiple thermal cycles. It balances thoroughness with practical test turnaround time.

What does it mean that charging and power-on were tested after the cycles?

Post-test functional checks — specifically power-on and charging — are the primary pass/fail indicators. If the internal battery, charging circuit, or control board were compromised by thermal stress, these functions would fail. A normal result on both checks confirms the HB1’s core electronics remained intact through the extreme temperature exposure.

What standard does this test follow?

The report references BTK internal form number BTK-R-Q-087A/1 and was conducted under BTK’s internal test protocol. The test conditions (60°C/80% RH for high temp, −20°C for low temp, 72-hour total storage) are consistent with common consumer product environmental durability requirements. The specific external standard cited is not listed in this report.