Document Overview
Key Findings The HB1 air pump (HB1-吹气泵) successfully passed the high/low temperature storage cycle test, showing no appearance anomalies or functional failures after exposure to extreme temperature conditions. Test Type: High/Low Temperature Storage Cycling (高低温存储测试) Report No.: 2025072801 Test Dates: 2025-07-25 to 2025-07-28 Product: HB1…
- Document type
- Test Report
- Prepared by
- Alex Newman
- Published
- Last reviewed
- Topics
- Environmental Testing
Key Findings
The HB1 air pump (HB1-吹气泵) successfully passed the high/low temperature storage cycle test, showing no appearance anomalies or functional failures after exposure to extreme temperature conditions.
- Test Type: High/Low Temperature Storage Cycling (高低温存储测试)
- Report No.: 2025072801
- Test Dates: 2025-07-25 to 2025-07-28
- Product: HB1 Air Pump (HB1-吹气泵)
- Manufacturer: BTK
- Sample Quantity: 3 pcs
- High Temperature Condition: 60°C, 80% RH, 2 hours
- Low Temperature Condition: −20°C, 2 hours
- Total Storage Duration: 72 hours
- Verdict: PASS — no appearance defects, no functional failure, normal power-on and charging after test
Test Overview
| Field | Details |
|---|---|
| Test Type | Environmental Testing — High/Low Temperature Storage Cycle (高低温存储测试) |
| Standard / Sheet | 高低温 (Sheet Index 1 of 1) |
| Report No. | 2025072801 |
| Page | 1 |
| Test Dates | 2025-07-25 to 2025-07-28 |
| Product | HB1 Air Pump (HB1-吹气泵) |
| Manufacturer | BTK |
| Surface Treatment | / |
| Sample Quantity | 3 pcs |
| Test Reason | New Product (■ New Product; Engineering Change Notice — No; Regular Verification — No; Quality Abnormal — No; Other — No) |
| Test Purpose | Evaluate the durability of the prototype during storage under extreme temperature environments |
| Laboratory Environment | Temperature: 24°C; Humidity: 45% RH |
| Test Class / Level | — |
| Product Line | Inflation Tools |
| Category | Air Pump / Blower Class (吹风机类) |
Test Equipment & Setup
| Item | Parameter | Value |
|---|---|---|
| Instrument | Name | Constant Temperature and Humidity Testing Machine (恒温恒湿试验机) |
| Test Condition 2.1 | High Temperature | 60°C, Humidity 80% RH, Duration 2 hours |
| Test Condition 2.2 | Low Temperature | −20°C, Duration 2 hours |
| Test Condition 2.3 | Total Storage Duration | 72 hours |
| Test Condition 2.4 | Post-Test Functional Check | Functional test required |
| Test Requirement | Objective | Verify stability under extreme environmental conditions |
Test Procedure
- Pre-Test: Record laboratory ambient conditions (Temperature: 24°C, Humidity: 45% RH). Inspect and document sample appearance for 3 pcs of HB1 air pump. Photograph samples before testing (程序控制图 / pre-test images captured).
- High Temperature Phase: Place samples in the constant temperature and humidity testing machine. Set chamber to 60°C and 80% RH. Maintain for 2 hours.
- Low Temperature Phase: Transition chamber to −20°C. Maintain for 2 hours.
- Cycle Continuation: Repeat high/low temperature cycles as required to complete a total cumulative storage duration of 72 hours.
- Post-Test Functional Check (2.4): Remove samples from chamber. Allow samples to return to ambient conditions. Power on each sample and verify normal operation. Verify charging function operates normally.
- Post-Test Appearance Inspection: Examine all 3 samples for any physical deformation, cracking, discoloration, or surface anomalies.
- Acceptance Criteria: No appearance abnormalities. All functional checks (power-on, charging) pass. Verdict recorded as Pass (合格), Fail (不合格), or Reference (参考).
Test Data & Results
| Check Item | Condition | Requirement | Result / Observation |
|---|---|---|---|
| Pre-Test Appearance | Ambient (24°C, 45% RH) | No defects | Normal — images captured (测试前程序控制图) |
| High Temperature Exposure | 60°C, 80% RH, 2 hours | No deformation, no failure | Completed |
| Low Temperature Exposure | −20°C, 2 hours | No cracking, no failure | Completed |
| Total Storage Duration | Cumulative cycling | 72 hours | Completed |
| Post-Test Power-On | Ambient recovery | Normal start-up | PASS — 开机正常 (Power-on normal) |
| Post-Test Charging | Ambient recovery | Charging functions correctly | PASS — 充电正常 (Charging normal) |
| Post-Test Appearance | Ambient recovery | No appearance anomalies | PASS — No anomalies observed |
| Overall Functional Test | Post-cycle | No functional failure | PASS — 功能无失效 |
Observations: All 3 samples of the HB1 air pump passed the extreme environment cyclic temperature/humidity shock test. Post-test inspection confirmed no appearance abnormalities (外观无异常) and no functional failures (功能无失效). Both power-on and charging operations were confirmed normal after the test cycle.
Conclusion
| Field | Details |
|---|---|
| Result | ■ Pass (合格Pass) |
| Fail / Reference | Fail — No; Reference — No |
| Test Standard / Conditions | High Temp: 60°C / 80% RH / 2 h; Low Temp: −20°C / 2 h; Total storage: 72 h |
| Samples Tested | 3 pcs — HB1 Air Pump (HB1-吹气泵), Manufacturer: BTK |
| Appearance Verdict | No abnormalities detected |
| Functional Verdict | No failures — power-on normal, charging normal |
| Overall Verdict | PASS |
Document Information
| Role | Name (Pinyin) |
|---|---|
| Approval (核准) | Mai Shaoqiang |
| Review / Check (审查) | Zhang Ronggui |
| Tester (试验人) | Li Guanghua |
| Form Number (表单编号) | BTK-R-Q-087A/1 |
| Report No. | 2025072801 |
| Page | 1 |
Frequently Asked Questions
What is a high/low temperature storage cycle test?
A high/low temperature storage cycle test exposes a product to alternating extremes of heat and cold while in a non-operating (stored) state. The purpose is to evaluate whether materials, joints, and components can withstand thermal expansion and contraction without cracking, deforming, or losing function. In this test, the HB1 was subjected to 60°C at 80% RH and −20°C in repeated cycles over a total of 72 hours.
Why is the total storage duration set to 72 hours?
72 hours is a commonly used benchmark in consumer electronics environmental testing because it provides sufficient time to stress-test material bonds, plastic housings, and internal electronics across multiple thermal cycles. It balances thoroughness with practical test turnaround time.
What does it mean that charging and power-on were tested after the cycles?
Post-test functional checks — specifically power-on and charging — are the primary pass/fail indicators. If the internal battery, charging circuit, or control board were compromised by thermal stress, these functions would fail. A normal result on both checks confirms the HB1’s core electronics remained intact through the extreme temperature exposure.
What standard does this test follow?
The report references BTK internal form number BTK-R-Q-087A/1 and was conducted under BTK’s internal test protocol. The test conditions (60°C/80% RH for high temp, −20°C for low temp, 72-hour total storage) are consistent with common consumer product environmental durability requirements. The specific external standard cited is not listed in this report.