ETENWOLF HB1 Blower Pump Noise Test Report (Ambient Sound Pressure Level, 1 m)

Document Overview

Key Findings All three HB1 blower pump samples produced sound pressure levels between 69.8 dB and 72.5 dB at 1 m horizontal distance from the front face during powered operation, falling within the evaluated range of 35–100 dB. Results are provided for reference only and…

Document type
Test Report
Prepared by
Alex Newman
Published
Last reviewed
Topics
Noise Testing

Key Findings

All three HB1 blower pump samples produced sound pressure levels between 69.8 dB and 72.5 dB at 1 m horizontal distance from the front face during powered operation, falling within the evaluated range of 35–100 dB. Results are provided for reference only and are not rated as pass/fail.

  • Product: HB1 Blower Pump (吹气泵)
  • Report No.: 2025072301
  • Test Date: 2025-07-23
  • Samples: 3 units (7#, 8#, 9#)
  • Measurement distance: 1 m, front face, horizontal
  • Sound pressure range measured: 69.8 – 72.5 dB
  • Evaluated criterion: Lmax 35–100 dB
  • Verdict: For Reference Only

Test Overview

Field Details
Report Title Ambient Noise Test Report (环境噪音测试报告)
Product No./Name HB1 Blower Pump (吹气泵)
Model / Type Specification HB1
Report No. 2025072301
Test Date 2025-07-23
Sample Quantity / No. 3 PCS
Type of Test ■ Reliability Test (可靠性测试)
Test Standard Internal Standard (内部标准)
Test Purpose Evaluate the noise level of the sample under different operating scenarios (评估样品在不同场景下的噪声水平)
Acceptance Criterion Evaluate sound pressure level of noise source (Lmax 35–100 dB)
Manufacturer / Brand ETENWOLF

Test Equipment & Setup

Item Details
Test Equipment Sound Level Meter (噪音计)
Microphone Placement 1 m horizontal distance from the front face of the product
Measurement Direction Front face (正面)
Ambient Temperature 23 °C
Relative Humidity 60 %
Test Conditions Label Room Temperature & Humidity: 23 °C, 60 %

Test Procedure

  1. Pre-test: Confirm ambient temperature (23 °C) and relative humidity (60 %) are within specified conditions. Verify the sound level meter is calibrated and ready.
  2. Sample placement: Position the HB1 blower pump on a stable surface. Place the sound level meter microphone at 1 m horizontal distance from the front face of the product.
  3. Power on: Switch the product to its powered-on operating state.
  4. Measurement: Record the maximum sound pressure level (dB) displayed on the sound level meter for each sample unit.
  5. Repeat: Perform the measurement for all three samples (7#, 8#, 9#) under identical conditions.
  6. Post-test: Power off each unit after measurement. Record all readings and compare against the evaluated criterion (Lmax 35–100 dB).
  7. Acceptance criteria: Results are evaluated against a sound pressure level range of Lmax 35–100 dB. This test is for reference only; no pass/fail verdict is assigned.

Test Data & Results

Sample No. (编号) Direction (方向) Distance from Microphone (距离麦克风距离) Noise Level — dB (噪音)
7# Front (正面) 1 m 70.9
8# Front (正面) 1 m 69.8
9# Front (正面) 1 m 72.5

Observations: All three samples operated within the evaluated sound pressure range of 35–100 dB. Sample 9# recorded the highest level at 72.5 dB; Sample 8# recorded the lowest at 69.8 dB. The spread across samples is 2.7 dB, indicating consistent acoustic output across the production lot. No anomalies were noted during measurement.

Conclusion

Field Details
Test Result Label ■ For Reference Only (供参考)
Pass / Fail Status □ Pass (合格)   □ Fail (不合格)   ■ For Reference Only (供参考)
Evaluated Standard Internal Standard — Lmax 35–100 dB
Test Conditions 23 °C, 60 % RH; microphone at 1 m horizontal distance, front face
Samples Tested 3 PCS (7#, 8#, 9#)
Measured Range 69.8 dB – 72.5 dB
Verdict For Reference Only — all readings within evaluated range

Document Information

Role Name (Pinyin) Date
Tested By (测试/日期) Li Guanghua 2025-07-23
Checked By (审核/日期) Zhang Ronggui 2025-07-23
Approved By (核准/日期) Mai Shaoqiang 2025-07-23
Source File HB1吹气泵-噪音测试 2025.7.23.xlsx
Sheet Name 噪音测试
Report No. 2025072301

Frequently Asked Questions

What is the measured noise level of the ETENWOLF HB1 blower pump?

During testing, the three HB1 samples recorded sound pressure levels of 70.9 dB, 69.8 dB, and 72.5 dB at 1 m horizontal distance from the front face while powered on. The average is approximately 71.1 dB.

What test standard was used for the HB1 noise test?

The test followed ETENWOLF’s internal standard, evaluating the sound pressure level (Lmax) of the noise source against a criterion range of 35–100 dB. No third-party international standard was applied for this report.

Does the HB1 blower pump pass the noise test?

This report is classified as For Reference Only. No formal pass or fail verdict was issued. All three samples fell within the evaluated range of 35–100 dB, confirming typical operational noise characteristics.

How was the HB1 noise measurement conducted?

The product was powered on and a calibrated sound level meter was positioned with its microphone at exactly 1 m horizontal distance from the front face of the unit. Measurements were taken under stable indoor conditions at 23 °C and 60 % relative humidity.