HB2 Pump RoHS Compliance Test Report – WTH25X07201672X1C

Document Overview

Document Overview This is an official RoHS Test Report issued by Waltek Testing Group (Shenzhen) Co., Ltd., a certified testing laboratory specializing in environmental compliance testing. The report confirms compliance with the EU RoHS Directive 2011/65/EU and its amendment (EU) 2015/863. Report Number: WTH25X07201672X1C Issue…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
European Union: CE / RoHS / REACH / WEEE

Document Overview

This is an official RoHS Test Report issued by Waltek Testing Group (Shenzhen) Co., Ltd., a certified testing laboratory specializing in environmental compliance testing. The report confirms compliance with the EU RoHS Directive 2011/65/EU and its amendment (EU) 2015/863.

  • Report Number: WTH25X07201672X1C
  • Issue Date: August 19, 2025
  • Testing Period: July 29, 2025 to August 13, 2025
  • Test Conclusion: PASS – The submitted samples comply with the requirements of EU RoHS Directive 2011/65/EU and its amendment (EU) 2015/863

Product Information

The tested product is the HB2 air pump, manufactured by Guangdong Bestek Technology Co., LTD and marketed under the ETENWOLF brand.

Parameter Details
Product Name PUMP 2
Model Number HB2
Brand ETENWOLF (manufactured by Guangdong Bestek Technology)
Manufacturer Guangdong Bestek Technology Co., LTD
Manufacturing Location No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R.China
Applicant Guangdong Bestek Technology Co., LTD
Sample Receipt Date July 29, 2025

Key Details

The HB2 pump was tested for 10 restricted substances as mandated by the EU RoHS Directive. The testing was conducted using internationally recognized analytical methods to detect the presence of hazardous materials in electrical and electronic equipment.

Restricted Substance Test Method Maximum Concentration Limit Test Result
Lead (Pb) IEC 62321-5:2013, ICP-OES 1000 mg/kg (0.1%) Pass
Mercury (Hg) IEC 62321-4:2013+AMD1:2017 CSV, ICP-OES 1000 mg/kg (0.1%) Pass
Cadmium (Cd) IEC 62321-5:2013, ICP-OES 100 mg/kg (0.01%) Pass
Hexavalent Chromium (Cr6+) IEC 62321-7-2:2017 / IEC 62321-7-1:2015, UV-Vis 1000 mg/kg (0.1%) Pass
Polybrominated Biphenyls (PBBs) IEC 62321-6:2015, GC-MS 1000 mg/kg (0.1%) Pass
Polybrominated Diphenyl Ethers (PBDEs) IEC 62321-6:2015, GC-MS 1000 mg/kg (0.1%) Pass
Phthalates (DEHP, BBP, DBP, DIBP) IEC 62321-8:2017, GC-MS 1000 mg/kg (0.1%) each Pass

The testing included initial screening by X-ray fluorescence spectrometry (XRF) per IEC 62321-3-1:2013, followed by confirmatory chemical analysis for detected elements. All tested components of the HB2 pump demonstrated compliance with maximum concentration limits.

Standards & Compliance

This RoHS test report demonstrates compliance with European Union regulations restricting hazardous substances in electrical and electronic equipment. The HB2 pump meets all requirements for sale in EU markets.

Applicable Directives and Standards

Test Methods Applied

  • IEC 62321-3-1:2013: Screening for lead, mercury, cadmium, total chromium and total bromine by XRF
  • IEC 62321-4:2013+AMD1:2017 CSV: Mercury determination by ICP-OES (Inductively Coupled Plasma Optical Emission Spectrometry)
  • IEC 62321-5:2013: Lead and cadmium determination by ICP-OES
  • IEC 62321-7-2:2017 and IEC 62321-7-1:2015: Hexavalent chromium determination by UV-Vis spectrophotometry
  • IEC 62321-6:2015: Polybrominated biphenyls and polybrominated diphenyl ethers in polymers by GC-MS (Gas Chromatography-Mass Spectrometry)
  • IEC 62321-8:2017: Phthalates determination by GC-MS

These internationally recognized IEC standards provide reliable, reproducible methods for detecting restricted substances in electronic products.

Validity & Certification Body

This RoHS compliance certificate was issued by Waltek Testing Group (Shenzhen) Co., Ltd., an accredited third-party testing laboratory specializing in environmental and safety compliance testing for electrical and electronic products.

Laboratory Information

Detail Information
Laboratory Name Waltek Testing Group (Shenzhen) Co., Ltd.
Address 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70 Bao’an District, Shenzhen, Guangdong, China
Website www.waltek.com.cn
Contact Phone +86-755-33663308
Contact Fax +86-755-33663309
Email [email protected]
Authorized Signatory Hugo Chen

Report Validity

This test report is valid from the date of issue (August 19, 2025) and applies to the specific samples tested. The report number WTH25X07201672X1C serves as the unique identifier for this certification. RoHS compliance should be maintained throughout the product lifecycle, and manufacturers should conduct periodic testing when materials or suppliers change.

Frequently Asked Questions

What does RoHS compliance mean for the HB2 pump?

RoHS (Restriction of Hazardous Substances) compliance means the HB2 pump does not contain restricted levels of 10 hazardous materials including lead, mercury, cadmium, hexavalent chromium, flame retardants (PBB, PBDE), and four phthalates. This ensures the product is safer for users and the environment.

Is the HB2 pump allowed to be sold in European markets?

Yes, the HB2 pump’s RoHS compliance is a mandatory requirement for sale in the European Union. This test report confirms the product meets EU Directive 2011/65/EU and its amendment (EU) 2015/863, making it legally compliant for European market distribution.

How often should RoHS testing be conducted?

While this report certifies the tested samples, manufacturers should conduct RoHS testing whenever there are changes to components, materials, suppliers, or manufacturing processes. Regular periodic testing (annually or bi-annually) is also recommended to ensure ongoing compliance throughout the product’s lifecycle.

What test methods were used to verify HB2 compliance?

Waltek Testing Group used internationally standardized IEC 62321 series methods including XRF screening, ICP-OES for metals, UV-Vis for hexavalent chromium, and GC-MS for organic compounds. These methods provide accurate, reliable detection of restricted substances at regulatory concentration limits.

Related Documents

For comprehensive compliance documentation of the HB2 pump, consider reviewing these related certification types:

  • CE Certification: Confirms conformity with EU health, safety, and environmental protection standards
  • REACH Compliance: Addresses Registration, Evaluation, Authorization and Restriction of Chemicals in EU markets
  • FCC Certification: Required for electromagnetic compatibility if the product contains electronic components
  • UN38.3 Battery Testing: If the HB2 pump includes lithium batteries, this certification verifies safe transport compliance
  • ISO 9001 Quality Management: Demonstrates the manufacturer’s quality control systems
  • Product Safety Testing: Additional safety certifications specific to the product category and target markets

These complementary certifications provide a complete compliance profile for global market access and demonstrate ETENWOLF’s commitment to quality and safety standards.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22
Document Page 23