ETENWOLF C2PV Tire Inflator Working Temperature Test Report (Environmental Testing, 2025-11-01)

Document Overview

Key Findings The C2PV inflation pump passed high/low temperature charge tests at 45°C and 0°C but failed the low-temperature discharge test at −20°C, triggering error code E13 (low-temperature protection), indicating that discharge performance at −20°C requires optimization. Product: C2PV Inflation Pump Report No.: 2025110101 Test…

Document type
Test Report
Prepared by
Daniel Wright
Published
Last reviewed
Topics
Environmental Testing

Key Findings

The C2PV inflation pump passed high/low temperature charge tests at 45°C and 0°C but failed the low-temperature discharge test at −20°C, triggering error code E13 (low-temperature protection), indicating that discharge performance at −20°C requires optimization.

  • Product: C2PV Inflation Pump
  • Report No.: 2025110101
  • Test Date: 2025-11-01
  • Samples: 2 PCS (C2PV-5#, C2PV-6#)
  • Test Type: Reliability Test — Working Temperature
  • Standard: Internal Control Standard
  • Charge Range Tested: 0°C to 45°C
  • Discharge Range Tested: −20°C to 74°C
  • Overall Verdict: For Reference Only (not fully passed — −20°C discharge fails requirement)

Test Overview

Field Detail
Test Type Environmental Testing — Working Temperature (Reliability Test)
Test Standard Internal Control Standard
Report No. 2025110101
Test Date 2025-11-01
Product No./Name Inflation Pump (充气泵)
Model / Specification C2PV
Manufacturer / Product Line ETENWOLF — Inflation Tools
Sample Quantity / ID 2 PCS — C2PV-5#, C2PV-6#
Test Purpose Evaluate the effect of high and low temperature storage conditions on the operational temperature performance of the sample
Test Environment Room Temperature: 23°C, Relative Humidity: 60%

Test Equipment & Setup

Item Detail
Test Equipment Constant Temperature & Humidity Chamber (恒温恒湿箱) / Power Meter (功率计)
Room Temperature 23°C
Room Humidity 60% RH
Charge Test Temperature Range 0°C to 45°C
Discharge Test Temperature Range −20°C to 74°C
Soak Duration per Condition 2 hours
Sample IDs Under Test C2PV-5#, C2PV-6#

Test Procedure

  1. Pre-Test: Place samples in the constant temperature and humidity chamber. Confirm room ambient conditions are 23°C / 60% RH before starting.
  2. High-Temperature Charge Test (45°C): Store samples at 45°C for 2 hours, then power on and verify that charging begins normally and current reading is normal.
  3. Low-Temperature Charge Test (0°C): Store samples at 0°C for 2 hours, then power on and verify that charging begins normally and current reading is normal.
  4. High-Temperature Discharge Test (74°C): Store samples at 74°C for 2 hours, then power on and verify that the unit operates normally in discharge mode and battery level display is normal.
  5. Low-Temperature Discharge Test (−20°C): Store samples at −20°C for 2 hours (report notes “−22°C” as the actual set point), then power on and record any error codes or anomalies.
  6. Post-Test: Return samples to room temperature, inspect for physical damage, and record all observations.
  7. Acceptance Criteria: Samples must operate normally at all specified environmental temperatures. Charge tests: 0°C–45°C. Discharge tests: −20°C–74°C. Any error code or failure to power on constitutes a non-conformance.

Test Data & Results

Sample ID Test Condition Observations / Issue Description
C2PV-5#–6# High-Temperature Charge Test — 45°C After 2 hours storage at 45°C, unit powers on, charging display is normal, current reading is normal.
C2PV-5#–6# Low-Temperature Charge Test — 0°C After 2 hours storage at 0°C, unit powers on, charging display is normal, current reading is normal.
C2PV-5#–6# High-Temperature Discharge Test — 74°C After 2 hours storage at 74°C, unit powers on and operates normally in discharge mode, battery level display is normal.
C2PV-5#–6# Low-Temperature Discharge Test — −22°C (set) / −20°C (spec) After 2 hours storage at −20°C, unit powers on and displays E13 (Low-Temperature Protection) — discharge function unavailable.

Observations: The high-temperature charge (45°C), low-temperature charge (0°C), and high-temperature discharge (74°C) tests all passed with normal operation. The low-temperature discharge test at −20°C resulted in error code E13 (low-temperature protection activated), meaning the sample does not meet the working temperature requirement for discharge at −20°C. Performance optimization is required for this condition.

Conclusion

Test Condition Standard / Requirement Samples Observed Result Verdict
Charge — 45°C Normal operation in specified temperature range (Internal Standard) C2PV-5#, C2PV-6# Normal charge, current normal Pass
Charge — 0°C Normal operation in specified temperature range (Internal Standard) C2PV-5#, C2PV-6# Normal charge, current normal Pass
Discharge — 74°C Normal operation in specified temperature range (Internal Standard) C2PV-5#, C2PV-6# Normal discharge, battery display normal Pass
Discharge — −20°C Normal operation in specified temperature range (Internal Standard) C2PV-5#, C2PV-6# E13 error (low-temperature protection) — discharge unavailable Fail — For Reference Only
Overall Internal Control Standard 2 PCS −20°C discharge performance does not meet requirement; optimization needed ■ For Reference Only (供参考)

Document Information

Role Name (Pinyin) Date
Tested By (测试/日期) Li Guanghua 2025-11-01
Checked By (审核/日期) Zhang Ronggui 2025-11-01
Approved By (核准/日期) Mai Shaoqiang 2025-11-01
Form Number (表单编号) BTK-R-Q142/AO

Frequently Asked Questions

What does error code E13 mean on the C2PV pump?

E13 indicates that the pump’s low-temperature protection circuit has activated. When the battery or internal temperature drops below the safe discharge threshold (around −20°C), the firmware prevents discharge to protect battery cells from damage. This is a safety feature, not a hardware defect, but it means the unit cannot deliver inflation performance at that temperature without design optimization.

Why did the pump pass the 0°C charge test but fail the −20°C discharge test?

Charging and discharging have different electrochemical tolerances. Lithium-based batteries can accept charge at 0°C within safe limits, but discharging at −20°C causes a significant drop in cell voltage and capacity, triggering the built-in protection threshold. The 0°C charge test and the 74°C discharge test both remained within the acceptable operating window, so only the −20°C discharge condition exceeded the protection boundary.

What does “For Reference Only” (供参考) mean as a verdict?

In ETENWOLF’s internal quality system, “For Reference Only” is a third verdict option between Pass and Fail. It is recorded when results are partially non-conforming or when the test is performed for characterization rather than compliance sign-off. In this case it signals that the −20°C discharge performance data has been captured and engineering action is required, but the report is not a formal compliance rejection.

What is the specified working temperature range for the C2PV?

Based on this test, the charging operating range is 0°C to 45°C (both verified as passing), and the discharge operating range targets −20°C to 74°C. The upper end (74°C discharge) passed, but −20°C discharge did not meet requirements as of this report dated 2025-11-01. The final rated specification may be updated after performance optimization is completed.

Related Products

Explore other products and test reports in the ETENWOLF Inflation Tools line: