REACH SVHC Test Report – ETENWOLF HB3 Air Pump (Report No. WTH25X09260773C)

Document Overview

Document Overview This article presents the findings of an official REACH SVHC Test Report issued by Waltek Testing Group (Shenzhen) Co., Ltd. under Report Number WTH25X09260773C. The report was issued on 2025-10-20 following a testing period from 2025-09-29 to 2025-10-13, with sample receipt recorded on…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
European Union: CE / RoHS / REACH / WEEE

Document Overview

This article presents the findings of an official REACH SVHC Test Report issued by Waltek Testing Group (Shenzhen) Co., Ltd. under Report Number WTH25X09260773C. The report was issued on 2025-10-20 following a testing period from 2025-09-29 to 2025-10-13, with sample receipt recorded on 2025-09-29.

The scope of this report covers compliance testing against European Commission Regulation (EC) No 1907/2006 (REACH), specifically the determination of 251 Substances of Very High Concern (SVHC) and 4 potential substances as listed on the ECHA Candidate List. The test conclusion confirms that all tested substance concentrations fall below the regulatory threshold of 0.1% (w/w).

Product Information

The tested product is an Air Pump marketed under the ETENWOLF HB3 product line. The specific model tested is designated PUMP5. Below is a summary of the product identification details as recorded in the test report:

Field Details
Sample Name AIR PUMP
Model No. PUMP5
Reference Model No. NA
Brand NA (marketed as ETENWOLF HB3)
Applicant Guangdong Bestek Technology Co., LTD
Manufacturer Guangdong Bestek Technology Co., LTD
Manufacturer Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R.China

The ETENWOLF HB3 air pump is a portable inflation tool designed for consumer and professional use, distributed globally under the ETENWOLF brand by Guangdong Bestek Technology Co., LTD.

Key Details

The test results confirm that all tested substance groups returned a result of Not Detected (ND), meaning concentrations of all 251 SVHC and 4 potential substances were below the reporting limit of 0.1% (w/w). The table below summarizes the test result groups as documented in Report No. WTH25X09260773C:

Group No. Substance Scope CAS No. Result (%, w/w) Reporting Limit (%, w/w)
T01 251 SVHC + 4 potential substances (Candidate List) Multiple ND 0.1
T02 251 SVHC + 4 potential substances (Candidate List) Multiple ND 0.1
T03 251 SVHC + 4 potential substances (Candidate List) Multiple ND 0.1

The full candidate list against which testing was conducted is maintained by the European Chemicals Agency (ECHA). A result of ND across all groups confirms that the ETENWOLF HB3 air pump does not contain SVHC substances at or above the 0.1% threshold in any homogeneous material, satisfying REACH Article 59 disclosure obligations.

Standards & Compliance

The testing was conducted using a combination of in-house methods referenced against internationally recognized analytical standards. The test methods applied for Report No. WTH25X09260773C are listed below:

Standard / Method Description
EPA 3550C:2007 Ultrasonic Extraction
US EPA 8270D:2018 Semivolatile Organic Compounds by GC/MS
US EPA 3052:1996 Microwave Assisted Acid Digestion of Siliceous and Organically Based Matrices
US EPA 3050B:1996 Acid Digestion of Sediments, Sludges, and Soils
US EPA 6010D:2018 Inductively Coupled Plasma – Optical Emission Spectrometry (ICP-OES)
BS EN ISO 14362-1:2017 Textiles – Methods for determination of certain aromatic amines derived from azo colorants – Part 1
BS EN ISO 14362-3:2017 Textiles – Methods for determination of certain aromatic amines derived from azo colorants – Part 3
ISO 17234-1:2020 Leather – Chemical tests for determination of certain azo colorants in dyed leathers – Part 1
ISO 17234-2:2011 Leather – Chemical tests for determination of certain azo colorants in dyed leathers – Part 2
ISO 17353:2004 Water quality – Determination of selected organotin compounds
AfPS GS 2019:01 PAK Testing for polycyclic aromatic hydrocarbons (PAHs) in consumer products

Compliance with REACH Regulation (EC) No 1907/2006 is mandatory for products placed on the European market. The SVHC candidate list is updated periodically by ECHA, and this report reflects the list status at the time of testing (251 substances + 4 potential).

Validity & Certification Body

The report was prepared and issued by Waltek Testing Group (Shenzhen) Co., Ltd., an accredited third-party testing laboratory. The signatory for the report is Hugo Chen, signing on behalf of Waltek Testing Group.

Field Details
Report Number WTH25X09260773C
Date of Issue 2025-10-20
Testing Period 2025-09-29 to 2025-10-13
Sample Receipt Date 2025-09-29
Testing Laboratory Waltek Testing Group (Shenzhen) Co., Ltd.
Lab Address 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70, Bao’an District, Shenzhen, Guangdong, China
Lab Website http://www.waltek.com.cn
Tel +86-755-33663308
Fax +86-755-33663309
Email [email protected]
Signed By Hugo Chen

REACH SVHC test reports do not carry a fixed expiry date; however, they are considered valid with respect to the ECHA Candidate List version current at the time of testing. Importers and distributors should ensure re-testing whenever the Candidate List is updated and new substances are added that may be relevant to the product composition.

Frequently Asked Questions

Q: What does REACH SVHC compliance mean for the ETENWOLF HB3 air pump?

REACH SVHC compliance means that the ETENWOLF HB3 air pump has been tested and confirmed to contain none of the 251 Substances of Very High Concern (SVHC) listed on the ECHA Candidate List at concentrations equal to or above 0.1% by weight in any homogeneous material. This is a requirement under European Regulation (EC) No 1907/2006 (REACH) for products sold in the EU and EEA.

Q: Who conducted the REACH SVHC testing for Report WTH25X09260773C?

The testing was performed by Waltek Testing Group (Shenzhen) Co., Ltd., a third-party accredited laboratory located in Shenzhen, China. The report was signed by Hugo Chen and issued on 2025-10-20 following a testing period from 2025-09-29 to 2025-10-13.

Q: How many SVHC substances were tested, and what was the outcome?

A total of 251 Substances of Very High Concern (SVHC) plus 4 additional potential substances from the ECHA Candidate List were tested across all sample groups. All results were reported as Not Detected (ND), confirming concentrations below the 0.1% (w/w) reporting limit in every tested material group.

Q: Does this REACH report cover all EU market requirements for the ETENWOLF HB3?

This report specifically addresses the SVHC substance disclosure obligation under REACH Article 59. It does not cover other EU compliance requirements such as CE marking, RoHS, or the Radio Equipment Directive (RED). For a complete compliance overview of the ETENWOLF HB3, additional certifications covering those areas would need to be reviewed alongside this REACH report.

Related Documents

For a comprehensive product compliance dossier for the ETENWOLF HB3 air pump, the following related certification and test report types are recommended:

  • RoHS Compliance Report – Restriction of Hazardous Substances; covers six restricted substances in electrical and electronic equipment under EU Directive 2011/65/EU.
  • CE Declaration of Conformity – Confirms the product meets all applicable EU harmonized legislation for market access within the European Economic Area.
  • FCC Declaration of Conformity – Required for products with electronic components sold in the United States market under FCC regulations.
  • UN 38.3 Battery Test Report – If the HB3 includes a lithium battery, this report certifies safe transport compliance under UN Recommendations on the Transport of Dangerous Goods.
  • KC Certification – Korea Certification mark required for electronic products sold in the Republic of Korea market.
  • ISO 9001 Quality Management Certificate – Demonstrates that the manufacturer’s quality management system meets ISO 9001 international standards.
  • PAHS / AfPS GS PAK Test Report – Polycyclic aromatic hydrocarbons testing for consumer products with accessible rubber or plastic surfaces, relevant for GS Mark compliance in Germany.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22
Document Page 23
Document Page 24
Document Page 25
Document Page 26