ETENWOLF S0 Portable Bike Pump Temperature Storage Cycle Test Report (High/Low Temp, 72 h)

Document Overview

Key Findings The ETENWOLF S0 portable bike pump completed a 72-hour high/low temperature storage cycle test under extreme thermal conditions and passed with no appearance anomalies or functional failures. Product: S0 Portable Bike Pump (S0-充气泵) Manufacturer: BTK Report No.: 2025080601 Test Period: 2025-08-02 to 2025-08-06…

Document type
Test Report
Prepared by
Daniel Wright
Published
Last reviewed
Topics
Environmental Testing

Key Findings

The ETENWOLF S0 portable bike pump completed a 72-hour high/low temperature storage cycle test under extreme thermal conditions and passed with no appearance anomalies or functional failures.

  • Product: S0 Portable Bike Pump (S0-充气泵)
  • Manufacturer: BTK
  • Report No.: 2025080601
  • Test Period: 2025-08-02 to 2025-08-06
  • Samples: 3 pcs
  • High-Temp Condition: 60 °C, 80 % RH, 2 h
  • Low-Temp Condition: −20 °C, 2 h
  • Total Storage Duration: 72 h
  • Verdict: Pass — unit powered on normally and charged normally after test

Test Overview

Field Detail
Test Type High/Low Temperature Storage Cycle Test (高低温存储测试)
Report No. 2025080601
Page 1
Test Date 2025-08-02 to 2025-08-06
Product Name ETENWOLF S0 Portable Bike Pump (S0-充气泵)
Manufacturer BTK
Surface Treatment /
Sample Quantity 3 pcs
Test Reason New Product (■ New Product)
Test Purpose Evaluate the durability of the prototype when stored in extreme temperature environments
Laboratory Environment Temperature 24 °C; Humidity 45 % RH

Test Equipment & Setup

Item Detail
Instrument Constant Temperature and Humidity Testing Machine (恒温恒湿试验机)
Condition 2.1 — High Temperature 60 °C, Humidity 80 % RH, Duration 2 h
Condition 2.2 — Low Temperature −20 °C, Duration 2 h
Condition 2.3 — Total Storage 72 h
Condition 2.4 — Post-Test Check Functional test
Test Requirement Verify stability under extreme environmental conditions

Test Procedure

  1. Pre-Test: Record baseline appearance and functional status of all 3 sample units. Confirm laboratory environment: 24 °C, 45 % RH.
  2. High-Temperature Exposure: Place samples in the constant temperature and humidity chamber. Set to 60 °C / 80 % RH. Hold for 2 hours.
  3. Low-Temperature Exposure: Adjust chamber to −20 °C. Hold for 2 hours.
  4. Extended Storage: Continue storage cycle to accumulate a total of 72 hours under the programmed temperature profile.
  5. Post-Test Functional Test: Remove samples from chamber. Power on each unit and verify normal operation. Verify charging function.
  6. Acceptance Criteria: No appearance abnormalities; all functional features operate normally after exposure.

Test Data & Results

Check Item Observation Result
Pre-Test Appearance Samples inspected before test commencement (pre-test image recorded) Normal
Program Control Profile Chamber temperature/humidity profile executed as programmed (program control chart recorded) Completed
Post-Test Power-On Unit powered on and operated normally after test (测试后开机工作正常) Pass
Post-Test Charging Charging function operated normally after test (充电正常) Pass
Overall Test Result Samples passed the extreme environment cyclic humid-heat shock test; no appearance anomalies, no functional failures (样品通过极端环境循环湿热冲击测试,外观无异常,功能无失效) Pass

Conclusion

Field Detail
Result Pass (■ 合格 Pass)
High-Temp Condition 60 °C / 80 % RH / 2 h
Low-Temp Condition −20 °C / 2 h
Total Storage Duration 72 h
Samples Tested 3 pcs
Appearance No anomalies
Functional Status No failures — power-on and charging both normal
Verdict The ETENWOLF S0 portable bike pump meets the extreme temperature storage requirements. All samples pass.

Document Information

Role Chinese Name Pinyin Name
Approval (核准) 麦少强 Mai Shaoqiang
Review (审查) 张荣贵 Zhang Ronggui
Tester (试验人) 李光华 Li Guanghua
Form Number BTK-R-Q-087A/1

Frequently Asked Questions

What temperature range was the ETENWOLF S0 pump tested to withstand in storage?

The ETENWOLF S0 was tested at a high-temperature extreme of 60 °C with 80 % relative humidity for 2 hours, and a low-temperature extreme of −20 °C for 2 hours, with a total programmed storage duration of 72 hours.

Did the ETENWOLF S0 pump pass the temperature storage cycle test?

Yes. All 3 samples passed. After completing the 72-hour high/low temperature storage cycle, every unit powered on normally and charged normally with no appearance anomalies or functional failures recorded.

What equipment was used for the ETENWOLF S0 temperature storage test?

A constant temperature and humidity testing machine (恒温恒湿试验机) was used to execute the programmed thermal profile across both high-temperature and low-temperature exposure phases.

Why is temperature storage testing important for a portable bike pump?

Portable bike pumps are frequently stored in environments such as car trunks, garages, or outdoor bags that can reach extreme temperatures. Temperature storage testing confirms that the product’s housing, battery, electronics, and seals remain intact and functional after prolonged exposure to heat and cold, ensuring reliability when the user actually needs the pump.

Related Products