ETENWOLF HB2 Tire Inflator Noise Test Report (76.8 dB Peak, 1 m Distance)

Document Overview

Key Findings Three HB2 inflator units were tested at 1 m frontal distance under standard room conditions, returning noise readings between 71.1 dB and 76.8 dB — logged for reference with no pass/fail threshold applied. Product: HB2 Air Inflator Pump Report No.: 2025042301 Test Date:…

Document type
Test Report
Prepared by
Alex Newman
Published
Last reviewed
Topics
Noise Testing

Key Findings

Three HB2 inflator units were tested at 1 m frontal distance under standard room conditions, returning noise readings between 71.1 dB and 76.8 dB — logged for reference with no pass/fail threshold applied.

  • Product: HB2 Air Inflator Pump
  • Report No.: 2025042301
  • Test Date: 2025-04-23
  • Samples: 3 units
  • Measurement position: 1 m horizontal from front face of unit, device powered on
  • Peak reading: 76.8 dB (Unit 1#)
  • Lowest reading: 71.1 dB (Unit 3#)
  • Verdict: For Reference Only — no normative noise limit applied

Test Overview

Field Detail
Product No. / Name Air Inflator Pump
Model / Type Specification HB2
Report No. 2025042301
Test Date 2025-04-23
Sample Quantity / No. 3 PCS
Type of Test Reliability Test
Test Standard Internal Standard
Normative Standard / (None specified)
Test Purpose Evaluate the noise level of the HB2 air inflator pump
Manufacturer / Brand ETENWOLF

Test Equipment & Setup

Item Detail
Test Equipment Sound Level Meter (Noise Meter)
Measurement Distance 1 m horizontal from the front face of the product
Device State During Test Unit powered on (operating state)
Ambient Temperature 23 °C
Relative Humidity 60 %
Test Environment Room temperature and humidity conditions

Test Procedure

  1. Pre-test: Confirm ambient conditions — temperature 23 °C, relative humidity 60 %. Verify sound level meter calibration.
  2. Sample preparation: Label three HB2 units as 1#, 2#, and 3#. Ensure each unit is fully assembled and functional.
  3. Microphone positioning: Place the sound level meter microphone at 1 m horizontal distance from the front face of the unit under test, at the same height as the unit.
  4. Measurement: Power on the unit. Allow it to reach steady operating state. Record the noise reading in dB from the sound level meter.
  5. Repeat: Perform the same measurement for each of the three samples in sequence.
  6. Post-test: Power off all units. Record all readings and environmental conditions in the test log.

Acceptance Criteria: No normative pass/fail limit is defined for this test. Results are logged for reference only (■ For Reference Only).

Test Data & Results

Sample No. Direction / Orientation Distance from Microphone Noise (dB)
1# Front Face (正面) 1 m 76.8
2# Front Face (正面) 1 m 72.6
3# Front Face (正面) 1 m 71.1

Observations: All three units were measured from the frontal direction at a 1 m standoff distance. Unit 1# returned the highest reading at 76.8 dB. Unit 3# returned the lowest at 71.1 dB. The spread across samples is 5.7 dB. No photographic test images have been included in this data extract. Because no normative upper limit was specified in the test standard field, the overall assessment is recorded as For Reference Only.

Conclusion

Field Detail
Test Item Noise Level Measurement
Standard Applied Internal Standard (no normative limit defined)
Test Conditions 23 °C, 60 % RH; microphone at 1 m frontal distance; unit powered on
Samples Tested 3 PCS (1#, 2#, 3#)
Results Range 71.1 dB – 76.8 dB
Pass (合格)
Fail (不合格)
Verdict ■ For Reference Only (供参考)

Document Information

Role Name (Pinyin) Date
Tested By (测试/日期) Li Guanghua 2025-04-23
Checked By (审核/日期) Zhang Ronggui 2025-04-23
Approved By (核准/日期) Mai Shaoqiang 2025-04-23
Report No. 2025042301
Source File HB2充气泵-噪音测试 2025.4.23.xlsx

Frequently Asked Questions

How loud is the ETENWOLF HB2 inflator pump during operation?

In controlled testing at 1 m frontal distance with the unit powered on, the three HB2 samples measured between 71.1 dB and 76.8 dB. The peak reading was 76.8 dB on sample 1#.

What test standard was used for the HB2 noise test?

The test was conducted against ETENWOLF’s internal standard. No external normative standard (such as IEC or ISO) was specified, so no pass/fail threshold was set. The results are recorded for reference only.

How was the noise measurement taken for the HB2?

A sound level meter was positioned at exactly 1 m horizontal distance from the front face of the HB2 unit. Each unit was powered on and in operating state during measurement. The test environment was held at 23 °C and 60 % relative humidity.

Did the ETENWOLF HB2 pass the noise test?

Because no normative upper noise limit was defined for this test, a formal pass or fail verdict was not issued. The assessment is marked as For Reference Only, meaning the data serves as a baseline record for the HB2 model rather than a compliance determination.

Related Products