FCC-SDoC Test Report WTH25H12333147E — ETENWOLF S1 Portable Tire Inflator

Document Overview

Document Overview This page presents the FCC Supplier’s Declaration of Conformity (SDoC) test report for the ETENWOLF S1 Portable Tire Inflator, issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd. The report certifies that the product complies with FCC CFR 47 Part 15 Subpart B…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
North America: FCC / UL

Document Overview

This page presents the FCC Supplier’s Declaration of Conformity (SDoC) test report for the ETENWOLF S1 Portable Tire Inflator, issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd. The report certifies that the product complies with FCC CFR 47 Part 15 Subpart B electromagnetic compatibility (EMC) requirements applicable to unintentional radiators sold or operated in the United States market.

Field Detail
Document Type FCC Supplier’s Declaration of Conformity (SDoC) — Test Report
Reference Number WTH25H12333147E
Test Report Form TRF FCC CFR 47 Part 15 Subpart B-EMC-001-V01
Internal Form Code HCT/RF-23-21
Issuing Laboratory Waltek Testing Group HCT (Shenzhen) Co., Ltd.
Date Sample Received 2025-12-12
Test Period 2025-12-15 to 2025-12-17
Date of Issue 2025-12-25
Overall Test Result Pass

Product Information

The Equipment Under Test (EUT) is the ETENWOLF S1 Portable Tire Inflator, a compact, battery-powered tire pump designed for automotive and recreational use. The unit supports two operating modes: a charging mode (Mode 1) and a working/inflation mode (Mode 2).

Field Detail
EUT Name Tire Pump
Trade Mark N/A
Model Number S1
Operating Mode 1 Charging Mode
Operating Mode 2 Working / Inflation Mode
Applicant Guangdong Bestek Technology Co., LTD
Applicant Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China
Manufacturer Guangdong Bestek Technology Co., LTD
Manufacturer Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China

Key Details

The test report covers two primary EMC measurement disciplines: Conducted Emission and Radiated Emission. Both were evaluated against the FCC limits defined under CFR 47 Part 15 Subpart B for unintentional radiators. All measured values fell within the prescribed limits, resulting in a full Pass determination.

Conducted Emission (Section 3)

Conducted emission measurements assess high-frequency noise injected back into the mains or power supply lines by the EUT. The test was performed with the EUT connected to its rated power source. Measurement uncertainty was documented per standard metrology requirements. The corrected emission levels were confirmed to be below the applicable FCC conducted emission limits across all tested frequency ranges.

Parameter Detail
Standard Applied FCC CFR 47 Part 15 Subpart B
Measurement Uncertainty Documented in Section 3.1 of the report
EUT Setup Per Section 3.3 — standard conducted emission bench configuration
Instrument Setup Per Section 3.4
Test Procedure Per Section 3.5
Result Pass

Radiated Emission (Section 4)

Radiated emission measurements evaluate electromagnetic energy radiated from the EUT into free space. Tests were conducted at an accredited EMC test facility using a calibrated test receiver. Corrected amplitude and margin calculations confirmed that all emission peaks remained below the FCC radiated emission limits.

Parameter Detail
Standard Applied FCC CFR 47 Part 15 Subpart B
Measurement Uncertainty Documented in Section 4.1 of the report
EUT Setup Per Section 4.3
Test Receiver Setup Per Section 4.4
Amplitude & Margin Calc. Per Section 4.6
Result Pass

Decision Rule

The laboratory applied a documented decision rule (Section 2.6) to account for measurement uncertainty when determining pass/fail status, consistent with ILAC-G8 guidelines and FCC policy for EMC testing.

Standards & Compliance

The ETENWOLF S1 was tested against the following regulatory standard:

Standard Scope Applicability
FCC CFR 47 Part 15 Subpart B Unintentional Radiators — Conducted & Radiated Emissions USA market

As an unintentional radiator classified under FCC Part 15 Subpart B, the S1 does not require an FCC ID but must comply with emission limits and be supported by an SDoC. This test report forms the technical basis for that declaration. The test report form reference is TRF FCC CFR 47 Part 15 Subpart B-EMC-001-V01.

No intentional radio transmitter modules were identified in the EUT configuration tested under this report. Equipment modifications were evaluated per Section 2.3 to confirm no changes affecting EMC performance were introduced prior to testing.

Validity & Certification Body

This test report was prepared and issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an independent third-party EMC testing laboratory located in Shenzhen, Guangdong, China.

Field Detail
Laboratory Name Waltek Testing Group HCT (Shenzhen) Co., Ltd.
Laboratory Address Building B, Tianji Industrial Park, 1/F. & 2/F. & 3/F., No.30-9, Laiyin Road, Xinsheng Community, Longgang Subdistrict, Longgang District, Shenzhen, Guangdong, China
Laboratory Website http://www.hct-test.com
Service Telephone 400-0066-989
Service Email [email protected]
Report Reference No. WTH25H12333147E
Date of Issue 2025-12-25
Prepared By Snow Zeng
Approved By Tony Wu
Report Validity Valid as issued for the tested configuration of model S1; remains applicable as long as the product design, components, and operating modes remain unchanged from the tested sample

The report covers 26 pages including test data sections, EUT photographs (Appendix A), and test setup photographs (Appendix B), providing a complete audit trail for FCC SDoC purposes.

Frequently Asked Questions

What does FCC CFR 47 Part 15 Subpart B mean for the ETENWOLF S1?

FCC CFR 47 Part 15 Subpart B sets limits on unintentional electromagnetic emissions from digital and electronic devices sold in the United States. The ETENWOLF S1 is classified as an unintentional radiator under this rule, meaning it must not produce conducted or radiated emissions that exceed FCC-specified limits. Test report WTH25H12333147E confirms the S1 passes all applicable limits.

Does the ETENWOLF S1 require an FCC ID?

No. The S1 does not contain an intentional radio transmitter and therefore does not require an FCC ID. It is authorized for the US market through a Supplier’s Declaration of Conformity (SDoC), which is supported by this test report (Reference No. WTH25H12333147E) demonstrating compliance with FCC Part 15 Subpart B emission limits.

Who conducted the FCC EMC testing for the S1?

Testing was performed by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an independent third-party EMC laboratory based in Longgang District, Shenzhen, China. The report was prepared by Snow Zeng and approved by Tony Wu, and issued on 2025-12-25.

What operating modes were tested during the FCC evaluation?

The S1 was tested in two operating modes: Mode 1 (Charging Mode), where the unit is connected to a power source for battery charging, and Mode 2 (Working/Inflation Mode), where the pump motor is actively running to inflate tires. Both modes were evaluated to ensure compliance under all typical use conditions.

Related Documents

For full market access and product compliance, the ETENWOLF S1 Portable Tire Inflator may also be supported by the following related certification and compliance documents:

  • CE Declaration of Conformity — Required for the European market, covering IEC-based EMC and Low Voltage Directive requirements.
  • UN 38.3 Battery Transport Test Report — Required for the lithium-ion battery pack within the S1, certifying safe air and ground transport compliance per UN38.3 standards.
  • RoHS Compliance Report — Confirms restriction of hazardous substances in accordance with RoHS Directive 2011/65/EU for EU market access.
  • REACH SVHC Declaration — Addresses REACH Regulation compliance for substances of very high concern present in the product.
  • KC Certification (Korea) — Required for sale in South Korea under the KC mark scheme, covering EMC and safety requirements.
  • ISO 9001 Quality Management Certificate — Issued to the manufacturer, demonstrating a certified quality management system supporting consistent production.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22
Document Page 23
Document Page 24
Document Page 25
Document Page 26