ETENWOLF S7 Tire Inflator Finished-Product Life Test Report (20-Hour Endurance, 3 Samples)

Document Overview

Key Findings All three ETENWOLF S7 tire inflator samples successfully completed the 20-hour cumulative discharge endurance test under a 35–40 psi load, with no functional failures or appearance defects observed at test conclusion. Test Type: Reliability — Finished-Product Life / Endurance Test Standard: Internal Control…

Document type
Certification Report
Prepared by
Daniel Wright
Published
Last reviewed
Topics
Mechanical Reliability

Key Findings

All three ETENWOLF S7 tire inflator samples successfully completed the 20-hour cumulative discharge endurance test under a 35–40 psi load, with no functional failures or appearance defects observed at test conclusion.

  • Test Type: Reliability — Finished-Product Life / Endurance Test
  • Standard: Internal Control Standard
  • Report No.: 2025062801
  • Test Period: 2025-05-16 to 2025-06-28
  • Samples: 3 PCS (Sample 1#, Sample 2#, Sample 3#)
  • Target Duration: 20 cumulative hours of discharge per unit
  • Load Condition: 35–40 psi, 12 V power source, 23 °C / 60 % RH
  • Verdict: For Reference Only (供参考)

Test Overview

Field Detail
Test Title S7 Tire Inflator — Finished-Product Life Test
Product No. / Name Tire Inflator (充气泵)
Model / Type Specification ETENWOLF S7
Report No. 2025062801
Test Date 2025-05-16 to 2025-06-28
Sample Quantity / No. 3 PCS
Test Type Reliability Test (可靠性测试)
Test Standard Internal Control Standard (内控标准)
Test Purpose Evaluate whether the sample’s service life affects functional performance
Acceptance Criteria Ensure no functional failure; observe stability and reliability

Test Equipment & Setup

Item Detail
Test Equipment Power supply / Load / Tire (电源 / 负载 / 轮胎)
Room Temperature 23 °C
Relative Humidity 60 %
Power Source 12 V
Load Pressure 35–40 psi
Target Cumulative Discharge Duration 20 hours per sample
Charge Time per Cycle (observed) Approx. 4 hours
Discharge Time per Cycle (observed) Approx. 40–45 minutes

Test Procedure

  1. Pre-test: Fully charge each S7 sample unit to 100 % battery capacity.
  2. Load setup: Connect the unit to a 35–40 psi load (tire) under room temperature (23 °C) and 60 % relative humidity, with a 12 V power source.
  3. Discharge cycle: Operate the inflator under the specified load until battery is fully depleted (one discharge cycle ≈ 40–45 minutes).
  4. Recharge: Recharge the unit fully (one charge cycle ≈ 4 hours) and repeat discharge cycles.
  5. Cycling: Continue charge–discharge cycles until each sample accumulates a total of 20 hours of cumulative discharge time.
  6. Monitoring: Record all error codes, appearance changes, and functional anomalies throughout the aging process.
  7. Post-test inspection: After reaching 20 cumulative hours, stop the test and inspect each sample for appearance defects, battery charge/discharge functionality, and any residual error codes.

Acceptance Criteria: All samples must complete 20 cumulative hours of discharge with no functional failure. Stability and reliability must be maintained throughout.

Test Data & Results

Sample ID Test Duration (Hours) Observations
Sample 1# (样机1#) 20

Post-life test observations:

  1. Appearance: No abnormality.
  2. Battery charge/discharge function normal; charge time approx. 4 hours per cycle; discharge time approx. 40–45 minutes per cycle.
  3. E14 (temperature protection) error appeared intermittently during the aging process. Test stopped after 20-hour life target reached. No further anomaly.
Sample 2# (样机2#) 20

Post-life test observations:

  1. Appearance: No abnormality.
  2. Battery charge/discharge function normal; charge time approx. 4 hours per cycle; discharge time approx. 40–45 minutes per cycle.
  3. E14 (temperature protection) error appeared intermittently during the aging process. After reaching the 20-hour life target, E11 (overcurrent alarm) appeared and the test was stopped.
Sample 3# (样机3#) 20

Post-life test observations:

  1. Appearance: No abnormality.
  2. Battery charge/discharge function normal; charge time approx. 4 hours per cycle; discharge time approx. 40–45 minutes per cycle.
  3. E14 (temperature protection) error appeared intermittently during the aging process. Test stopped after 20-hour life target reached. No further anomaly.

Test Picture Notes: Photos documented include: (1) unit under life/endurance test cycling; (2) overcurrent alarm E11 display; (3) inflation accuracy and inflation time testing during the life test process; (4) unit during the aging/burn-in test phase.

Overall Test Result: All 3 PCS of S7 tire inflator samples successfully reached the 20-hour life test target (S7充气泵寿命测试3pcs,均能到达20小时寿命测试).

Conclusion

Item Detail
Result For Reference Only (供参考 ■)
Pass Not formally marked as Pass (口合格)
Fail Not marked as Fail (口不合格)
Standard Applied Internal Control Standard — 20-hour cumulative discharge endurance
Test Conditions 35–40 psi load, 12 V, 23 °C, 60 % RH
Samples Tested 3 PCS
Functional Verdict All 3 samples completed 20-hour life test. E14 (temperature protection) appeared intermittently on all units; E11 (overcurrent alarm) appeared on Sample 2# at end of test. No structural or appearance failures detected.

Document Information

Role Name (Pinyin) Date
Tested By (测试/日期) Li Guanghua 2025-06-28
Checked By (审核/日期) Zhang Ronggui 2025-06-28
Approved By (核准/日期) Mai Shaoqiang 2025-06-28
Form No. BTK-R-Q142/AO

Frequently Asked Questions

How many hours does the ETENWOLF S7 tire inflator endurance test run?

The S7 finished-product life test requires each sample to accumulate 20 cumulative hours of discharge operation under a 35–40 psi load. This is achieved through repeated charge–discharge cycles, with each discharge cycle lasting approximately 40–45 minutes and each recharge cycle taking approximately 4 hours.

What do the E14 and E11 error codes mean on the ETENWOLF S7?

E14 is a temperature protection code that triggers when the unit’s internal temperature exceeds a safe threshold during extended operation. It appeared intermittently on all three samples during the 20-hour aging process. E11 is an overcurrent alarm that appeared on Sample 2# at the conclusion of its 20-hour test. Neither code caused a functional failure during the endurance test period.

Did all S7 samples pass the 20-hour life test?

Yes. All 3 PCS of S7 tire inflator samples reached the 20-hour cumulative discharge target. No appearance defects were observed, and battery charge/discharge functionality remained normal throughout. The report is issued as For Reference Only (供参考) rather than a formal Pass/Fail certification under a third-party standard.

What load and conditions were used for the S7 life test?

The test was conducted at room temperature (23 °C) and 60 % relative humidity, using a 12 V power source and a tire load maintained at 35–40 psi. These conditions reflect typical real-world use to evaluate the inflator’s operational stability and reliability over its service life.