CE-LVD Test Report for ETENWOLF Air3 Portable Blowing Pump – WTH25X07182968J

Document Overview

Document Overview This article covers the official CE Low Voltage Directive (LVD) test report issued by Waltek Testing Group (Shenzhen) Co., Ltd. for the ETENWOLF Air3 portable blowing pump. The document is a full safety evaluation report compiled in accordance with the EU LVD framework,…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
European Union: CE / RoHS / REACH / WEEE

Document Overview

This article covers the official CE Low Voltage Directive (LVD) test report issued by Waltek Testing Group (Shenzhen) Co., Ltd. for the ETENWOLF Air3 portable blowing pump. The document is a full safety evaluation report compiled in accordance with the EU LVD framework, verifying that the product meets the essential safety requirements for household and similar electrical appliances before placement on the EU market.

  • Document Type: CE-LVD Test Report
  • Reference Number: WTH25X07182968J
  • Test Report Form No.: WTX_EN IEC 60335_1_2023B
  • Issuing Body: Waltek Testing Group (Shenzhen) Co., Ltd., 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70 Bao’an District, Shenzhen, Guangdong, China
  • Date of Receipt of Sample: 2025-07-11
  • Date of Testing: 2025-07-11 to 2025-07-16
  • Date of Issue: 2025-07-17
  • Overall Test Result: Pass

The report was prepared by John Zhong (Project Engineer) and approved by Harvid Wei (Manager) at Waltek Testing Group. The results apply exclusively to the sample(s) submitted for testing and may not be reproduced in part without prior written permission from the issuing laboratory.

Product Information

The tested product is the Air3, a portable blowing pump designed and manufactured by Guangdong Bestek Technology Co., Ltd. for household and indoor use. Below are the key product details documented in the test report.

Field Detail
Product Name Portable Blowing Pump
Model Number Air3
Trademark
Rated Input Voltage 5 V DC
Rated Input Current 2.0 A
Supply Connection DC Connector
Equipment Class Class III
Installation / Use Portable appliance, indoor use only
Ingress Protection IPX0
Applicant Guangdong Bestek Technology Co., Ltd.
Manufacturer Guangdong Bestek Technology Co., Ltd.
Manufacturer Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China
Country of Manufacture China

The Air3 operates on extra-low voltage (Class III), drawing power via a DC connector at 5 V / 2.0 A. It is intended for household and similar indoor environments only. Note that the LED lighting components of the unit were not evaluated within the scope of this report.

Key Details

The following table summarises the key test clauses evaluated under EN IEC 60335-1:2023+A11:2023 for the Air3, along with their verdicts as documented in test report WTH25X07182968J.

Clause Requirement / Test Area Verdict
Clause 5 General Conditions for the Tests (nature of supply, sequence of testing) Pass
Clause 6 Classification Pass
6.1 Protection against electric shock — Class III Pass
6.2 Protection against harmful ingress of water — IPX0 N/A
Clause 7 Marking and Instructions Pass
7.1 Rated voltage, current, manufacturer identification, model reference on marking label Pass
7.1 Symbol IEC 60417-5180 for Class III appliances (battery-operated / rechargeable) Pass
7.1 Appliances supplied from a detachable power supply part Pass
7.2 Warning for stationary appliances for multiple supply N/A
7.3 Range of rated values marking N/A

Additional marking requirements confirmed in the report include: the CE mark must have a minimum height of 5 mm, the WEEE mark a minimum height of 7 mm, and both the name and address of the EU importer and manufacturer must be affixed to the product when placed on the EU market. The importer name and address fields on the sample label were listed as placeholders (XXX) at the time of testing, pending assignment of an EU-based importer.

All testing was conducted at Waltek Testing Group (Shenzhen) Co., Ltd. No test items were subcontracted to other laboratories.

Standards & Compliance

The Air3 was evaluated against the following harmonised European standards as part of the CE-LVD assessment:

Standard Title Scope
EN IEC 60335-1:2023+A11:2023 Household and Similar Electrical Appliances — Safety — Part 1: General Requirements Primary safety standard covering construction, testing, and performance requirements for household electrical appliances
EN 62233:2008 Measurement Methods for Electromagnetic Fields of Household Appliances and Similar Apparatus with Regard to Human Exposure Defines measurement methods to assess electromagnetic field (EMF) exposure levels relative to human safety limits

The product is classified as a Class III appliance, meaning it operates at safety extra-low voltage (SELV) and relies on the supply voltage itself as its primary protection against electric shock — no protective earthing is required. The ingress protection rating is IPX0, indicating no specific protection against water ingress, consistent with its indoor-only use classification.

Both standards applied are harmonised under the EU Low Voltage Directive (LVD) 2014/35/EU, which governs the safety of electrical equipment designed for use within certain voltage limits. Compliance with these standards supports the product’s CE marking obligations.

Validity & Certification Body

The following details govern the validity and authority of test report WTH25X07182968J:

Field Detail
Report Reference Number WTH25X07182968J
Date of Issue 2025-07-17
Testing Period 2025-07-11 to 2025-07-16
Sample Receipt Date 2025-07-11
Issuing Laboratory Waltek Testing Group (Shenzhen) Co., Ltd.
Laboratory Address 1/F., Room 101, Building 1, Hongwei Industrial Park, Liuxian 2nd Road, Block 70 Bao’an District, Shenzhen, Guangdong, China
Laboratory Website http://www.waltek.com.cn
Laboratory Contact Tel: +86-755-33663308 | Fax: +86-755-33663309 | Email: [email protected]
Prepared By John Zhong, Project Engineer
Approved By Harvid Wei, Manager
Report Validity Valid for the tested sample(s) only; report is invalid without the specific stamp of the test institute and signatures of the approver
Reproduction Policy Report may not be reproduced except in full, with prior written permission from Waltek Testing Group

Waltek Testing Group (Shenzhen) Co., Ltd. is an accredited third-party testing laboratory providing certification and compliance testing services for global markets. The validity of this report is tied to the specific sample(s) tested; results are not transferable to other units or production batches without separate evaluation.

Frequently Asked Questions

What does the CE-LVD test report for the Air3 confirm?

The CE-LVD test report (Reference No. WTH25X07182968J) confirms that the Air3 portable blowing pump passed all applicable safety requirements under EN IEC 60335-1:2023+A11:2023 and EN 62233:2008. This means the product meets the essential safety requirements of the EU Low Voltage Directive (2014/35/EU) and is eligible to carry the CE mark for placement on the European market.

What equipment class is the Air3, and why does it matter?

The Air3 is a Class III appliance, which means it operates at safety extra-low voltage (SELV) — in this case 5 V DC at 2.0 A. Class III classification indicates the product relies on the low supply voltage as its primary protection against electric shock, rather than insulation or earthing. This makes it inherently safer for household use and aligns with its portable, indoor-only design.

Were all tests conducted at Waltek’s own laboratory?

Yes. According to the test report, all testing for report WTH25X07182968J was conducted entirely at Waltek Testing Group (Shenzhen) Co., Ltd.’s facility in Bao’an District, Shenzhen. No test items were subcontracted to any other laboratory.

Does this report cover the LED lighting function of the Air3?

No. The test report explicitly states that the LED lights incorporated in the Air3 were not evaluated within the scope of this report. The CE-LVD assessment covers the core electrical safety and EMF exposure aspects of the pump function only. LED-related compliance may be addressed under separate documentation.

Related Documents

The CE-LVD test report is one component of a broader compliance documentation package typically required for the Air3 portable blowing pump. The following related certification and documentation types are relevant for a complete market access and compliance profile:

  • CE-EMC Test Report — Electromagnetic compatibility testing under the EU EMC Directive (2014/30/EU), typically covering EN 55014-1 (emissions) and EN 55014-2 (immunity) for household appliances.
  • CE Declaration of Conformity (DoC) — The manufacturer’s formal declaration that the Air3 meets all applicable EU directives, required to affix the CE mark and place the product on the EU market.
  • CE-RED Test Report — If the Air3 incorporates any wireless or radio frequency functionality (e.g., Bluetooth), a Radio Equipment Directive (2014/53/EU) test report would be required.
  • UN 38.3 Battery Safety Test Report — If the Air3 is powered by a lithium-ion or lithium-polymer rechargeable battery, UN 38.3 certification is required for safe transport of lithium batteries by air, sea, and road.
  • RoHS Compliance Report / Test Report — Confirms restriction of hazardous substances (lead, mercury, cadmium, etc.) under EU RoHS Directive 2011/65/EU, required for all electrical and electronic equipment placed on the EU market.
  • REACH SVHC Declaration — Documents compliance with REACH Regulation (EC) No 1907/2006 regarding substances of very high concern in the product’s materials.
  • FCC / IC Certification — Required for sale in the United States and Canada respectively, covering radio frequency emissions and interference standards.
  • KC Certification — Required for sale in South Korea under the KC safety mark framework covering electrical safety and EMC.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22
Document Page 23
Document Page 24
Document Page 25
Document Page 26
Document Page 27
Document Page 28
Document Page 29
Document Page 30
Document Page 31
Document Page 32
Document Page 33
Document Page 34
Document Page 35
Document Page 36
Document Page 37
Document Page 38
Document Page 39
Document Page 40
Document Page 41
Document Page 42
Document Page 43
Document Page 44
Document Page 45
Document Page 46
Document Page 47
Document Page 48
Document Page 49
Document Page 50
Document Page 51
Document Page 52
Document Page 53
Document Page 54
Document Page 55
Document Page 56
Document Page 57
Document Page 58
Document Page 59
Document Page 60
Document Page 61
Document Page 62
Document Page 63
Document Page 64
Document Page 65
Document Page 66
Document Page 67
Document Page 68
Document Page 69
Document Page 70
Document Page 71
Document Page 72
Document Page 73
Document Page 74
Document Page 75
Document Page 76
Document Page 77
Document Page 78
Document Page 79
Document Page 80
Document Page 81
Document Page 82
Document Page 83
Document Page 84
Document Page 85
Document Page 86
Document Page 87
Document Page 88
Document Page 89
Document Page 90
Document Page 91
Document Page 92
Document Page 93
Document Page 94
Document Page 95
Document Page 96
Document Page 97
Document Page 98
Document Page 99
Document Page 100
Document Page 101
Document Page 102
Document Page 103
Document Page 104
Document Page 105
Document Page 106
Document Page 107
Document Page 108
Document Page 109
Document Page 110
Document Page 111
Document Page 112
Document Page 113
Document Page 114
Document Page 115
Document Page 116
Document Page 117
Document Page 118
Document Page 119
Document Page 120
Document Page 121
Document Page 122
Document Page 123
Document Page 124
Document Page 125
Document Page 126
Document Page 127
Document Page 128