Document Overview
Key Findings The ETENWOLF S6 heavy-duty cordless inflator passed all six-face drop tests from 100 cm with no structural cracking, no latch failure, and normal powered-on operation after every drop. Product: S6 Electric Cordless Inflator (S6-电动充气泵) Drop Height: 100 cm Drop Faces: 6 (one drop…
- Document type
- Test Report
- Prepared by
- Daniel Wright
- Published
- Last reviewed
- Topics
- Mechanical Reliability
Key Findings
The ETENWOLF S6 heavy-duty cordless inflator passed all six-face drop tests from 100 cm with no structural cracking, no latch failure, and normal powered-on operation after every drop.
- Product: S6 Electric Cordless Inflator (S6-电动充气泵)
- Drop Height: 100 cm
- Drop Faces: 6 (one drop per face, 6 total)
- Samples Tested: 3 units
- Manufacturer: BTK
- Test Date: 2025-05-26
- Report No.: 2025052601
- Verdict: Pass
Test Overview
| Field | Details |
|---|---|
| Test Type | Drop Test (Mechanical Reliability) |
| Report No. | 2025052601 |
| Page | 1.0 |
| Date | 2025-05-26 |
| Product Name | ETENWOLF S6 Heavy-Duty Cordless Inflator (S6-电动充气泵) |
| Manufacturer | BTK |
| Surface Treatment | — |
| Sample Quantity | 3 PCS |
| Test Reason | New Product |
| Test Objective | Evaluate the product’s anti-drop impact capability and verify finished-product reliability by simulating real-world drop conditions. |
| Laboratory Temperature | 22 °C |
| Laboratory Humidity | 55 % RH |
Test Equipment & Setup
| Parameter | Details |
|---|---|
| Instrument Name | Single-Arm Drop Testing Machine (单臂跌落试验机) |
| Drop Height | 100 cm |
| Number of Drops | 6 faces (6 drops total) |
| Acceptance Criteria | Normal appearance and function after drop; housing must show no cracking |
Test Procedure
- Pre-Test: Record ambient temperature (22 °C) and humidity (55 % RH). Inspect all 3 sample units for pre-existing damage and confirm powered-on operation is normal.
- Setup: Mount the single-arm drop testing machine. Set drop height to 100 cm.
- Drop Execution: Drop each sample unit once per face for a total of 6 drops (Face 1 through Face 6), following the standard 6-face drop sequence.
- Post-Drop Inspection — Visual: Examine housing for cracks or latch/clip detachment after each drop.
- Post-Drop Inspection — Functional: Power on the unit after all 6 drops and verify normal operation with no display anomalies.
- Acceptance Criteria: Housing shows no cracking; all latches/clips remain intact; unit powers on and runs normally after the full 6-face drop sequence.
Test Data & Results
| Drop No. | Face | Visual Observation | Functional Check |
|---|---|---|---|
| 1 | Face 1 | Housing — no cracking | Normal |
| 2 | Face 2 | Housing — no cracking | Normal |
| 3 | Face 3 | No cracking; display normal, no missing pixels | Normal |
| 4 | Face 4 | No cracking; display normal, no missing pixels | Normal |
| 5 | Face 5 | Post-drop power-on operation normal | Normal |
| 6 | Face 6 | Post-drop power-on operation normal | Normal |
Overall Observation: After 100 cm single-arm drops across all 6 faces, sample units showed no housing cracks, no latch or clip detachment, and normal powered-on operation post-drop. Test images captured: pre-drop setup, single-arm drop testing machine, power controller, and all six individual drop impacts.
Conclusion
| Item | Details |
|---|---|
| Result | Pass |
| Test Standard | 6-face single-arm drop test |
| Drop Height | 100 cm |
| Samples Evaluated | 3 PCS |
| Visual Verdict | No cracking, no latch detachment |
| Functional Verdict | Powers on and runs normally after all 6 drops |
| Overall Verdict | ■ Pass □ Fail □ Reference |
Document Information
| Role | Name (Pinyin) |
|---|---|
| Approval (核准) | Mai Shaoqiang |
| Review (审查) | Zhang Ronggui |
| Tester (试验人) | Li Guanghua |
| Form Number | BTK-R-Q-087A/1 |
Frequently Asked Questions
What drop height was used in the ETENWOLF S6 drop test?
The S6 was tested at a drop height of 100 cm using a single-arm drop testing machine, covering all 6 faces of the unit for a total of 6 individual drops.
Did the ETENWOLF S6 pass the 6-face drop test?
Yes. All 3 sample units passed. After 100 cm drops across all 6 faces, the housing showed no cracking or latch detachment, and every unit powered on and operated normally post-drop.
What are the acceptance criteria for the S6 drop test?
The product must show no housing cracks and no latch or clip failures, and must power on and function normally after completing the full 6-face drop sequence from 100 cm.
Who approved the ETENWOLF S6 drop test report?
The report was approved by Mai Shaoqiang, reviewed by Zhang Ronggui, and the testing was conducted by Li Guanghua. The form number is BTK-R-Q-087A/1.
Related Products