FCC SDoC Test Report for ETENWOLF Air3 Portable Inflation Pump – Report WTH25H07182969E

Document Overview

Document Overview This page presents the structured knowledge base entry for FCC Supplier’s Declaration of Conformity (SDoC) Test Report reference number WTH25H07182969E, issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd. (internal form reference HCT/RF-23-21). The document is a formal electromagnetic compatibility (EMC) test report…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
North America: FCC / UL

Document Overview

This page presents the structured knowledge base entry for FCC Supplier’s Declaration of Conformity (SDoC) Test Report reference number WTH25H07182969E, issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd. (internal form reference HCT/RF-23-21). The document is a formal electromagnetic compatibility (EMC) test report prepared in accordance with FCC CFR 47 Part 15 Subpart B, which governs unintentional radiators sold or operated within the United States.

  • Document Type: FCC SDoC Test Report
  • Reference Number: WTH25H07182969E
  • Test Report Form: TRF FCC CFR 47 Part 15 Subpart B-EMC-001-V01
  • Issuing Laboratory: Waltek Testing Group HCT (Shenzhen) Co., Ltd.
  • Sample Received: 2025-07-10
  • Date of Test: 2025-07-14
  • Date of Issue: 2025-07-25
  • Overall Test Result: Pass

The report covers both conducted emission and radiated emission measurements performed on the Equipment Under Test (EUT), confirming that the product meets all applicable FCC Part 15 Subpart B limits.

Product Information

The Equipment Under Test (EUT) evaluated in this report is the ETENWOLF Air3, a compact portable blowing pump designed for inflation tasks including vehicle tyres, bicycle tyres, sports equipment, and other inflatable items.

Field Detail
Product Name Portable Blowing Pump
Model Number Air3
Trade Mark N/A
Applicant Guangdong Bestek Technology Co., Ltd.
Manufacturer Guangdong Bestek Technology Co., Ltd.
Applicant / Manufacturer Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R.China
Operating Modes Mode 1: Charging; additional operating modes as defined in the full report

The Air3 is classified as an unintentional radiator under FCC rules, meaning it does not intentionally transmit radio frequency energy but must still comply with emission limits to avoid interference with licensed radio services.

Key Details

The test report covers two primary EMC test disciplines: Conducted Emission and Radiated Emission. Below is a summary of the key test parameters and findings from report WTH25H07182969E.

Conducted Emission (Section 3)

Parameter Detail
Frequency Range As defined by FCC CFR 47 Part 15 Subpart B conducted limits
Measurement Uncertainty Documented in Section 3.1 of the full report
EUT Setup Per Section 3.3 — standard conducted emission bench configuration
Instrument Setup Per Section 3.4
Test Result Pass

Radiated Emission (Section 4)

Parameter Detail
Frequency Range As defined by FCC CFR 47 Part 15 Subpart B radiated limits
Measurement Uncertainty Documented in Section 4.1 of the full report
EUT Setup Per Section 4.3 — open area test site or equivalent shielded enclosure
Corrected Amplitude & Margin Calculated per Section 4.6; all margins confirmed positive
Test Result Pass

Test Personnel

Role Name
Tested By Snow Zeng
Approved By Tony Wu

Decision rules for pass/fail determination were applied per Section 2.6 of the report. No equipment modifications were required (Section 2.3). Supporting photographs of the EUT and test setup are included in Appendix A and Appendix B of the full report respectively.

Standards & Compliance

The Air3 was evaluated against the following regulatory standard:

Standard Scope Authority
FCC CFR 47 Part 15 Subpart B Unintentional radiators — conducted and radiated emission limits Federal Communications Commission (FCC), USA

FCC Part 15 Subpart B sets mandatory emission limits for digital devices and other electronic equipment that may unintentionally generate radio frequency energy. Compliance ensures the product does not cause harmful interference to authorized radio communications services operating across the United States.

The test methodology followed the procedures outlined in Test Report Form TRF FCC CFR 47 Part 15 Subpart B-EMC-001-V01, covering:

  • Conducted emission measurement procedures (Section 3.5)
  • Radiated emission measurement procedures (Section 4.5)
  • Application of the laboratory’s documented decision rule (Section 2.6)
  • Measurement uncertainty budgets for both conducted and radiated tests (Sections 3.1 and 4.1)

All test equipment used during the evaluation is listed with calibration details in Sections 3.6 and 4.7 of the full report.

Validity & Certification Body

This FCC SDoC test report was issued on 2025-07-25 and supports the applicant’s Supplier’s Declaration of Conformity for the Air3 portable blowing pump.

Field Detail
Report Reference Number WTH25H07182969E
Internal Form Reference HCT/RF-23-21
Date of Issue 2025-07-25
Testing Laboratory Waltek Testing Group HCT (Shenzhen) Co., Ltd.
Laboratory Address Building B, Tianji Industrial Park, 1/F. & 2/F. & 3/F., No.30-9, Laiyin Road, Xinsheng Community, Longgang Subdistrict, Longgang District, Shenzhen, Guangdong, China
Laboratory Tel 0755-84616666
Laboratory Service Tel 400-0066-989
Laboratory Email [email protected]
Laboratory Website http://www.hct-test.com
Regulatory Framework FCC SDoC — self-declaration by the responsible party based on this test report

Under the FCC SDoC framework, the manufacturer or importer (responsible party) declares conformity based on test results from an accredited laboratory. This report serves as the technical basis for that declaration. The report remains valid as long as the product design and manufacturing process remain unchanged from the tested configuration.

Frequently Asked Questions

What does the FCC SDoC test result mean for the ETENWOLF Air3?

A passing result on report WTH25H07182969E confirms that the Air3 portable blowing pump meets the conducted and radiated emission limits defined in FCC CFR 47 Part 15 Subpart B. This means the product can be legally marketed and sold in the United States without causing harmful interference to licensed radio services.

What is the difference between FCC SDoC and FCC ID certification?

FCC ID certification requires third-party review and assignment of an FCC ID number, typically required for intentional radiators such as Wi-Fi or Bluetooth devices. FCC SDoC (Supplier’s Declaration of Conformity) applies to unintentional radiators like the Air3, where the manufacturer or importer self-declares conformity based on accredited laboratory test results — in this case report WTH25H07182969E issued by Waltek Testing Group HCT.

Which emissions were tested in report WTH25H07182969E?

The report covers two emission categories required by FCC CFR 47 Part 15 Subpart B: conducted emissions (interference transmitted back through the power line) and radiated emissions (electromagnetic energy radiated through the air). Both tests returned a Pass result for the Air3.

Does the FCC SDoC certification cover all markets globally?

No. The FCC SDoC certification covers the United States market only. For sales in the European Union, the product requires CE marking with EMC Directive compliance. For South Korea, KC certification is required. ETENWOLF pursues the relevant certifications for each target market independently.

Related Documents

The following certification and compliance documents are relevant to the ETENWOLF Air3 portable blowing pump and complement this FCC SDoC test report:

  • CE EMC Declaration of Conformity — Required for the EU market under the EMC Directive 2014/30/EU, covering similar conducted and radiated emission tests to ETSI and IEC standards.
  • CE LVD (Low Voltage Directive) Test Report — Evaluates electrical safety for battery-powered and charging-capable portable devices under EU Directive 2014/35/EU.
  • UN 38.3 Battery Transport Test Report — If the Air3 contains a lithium-ion or lithium-polymer battery, a UN 38.3 test report is required for safe air and ground transport.
  • RoHS Compliance Report — Confirms restriction of hazardous substances per RoHS Directive 2011/65/EU, applicable for EU market entry.
  • REACH SVHC Declaration — Documents compliance with REACH Regulation (EC) No 1907/2006 regarding substances of very high concern.
  • KC Certification (South Korea) — Required for electrical and electronic products sold in South Korea under the Radio Waves Act and Electrical Appliances Safety Act.
  • Product Safety Test Report (IEC 62368-1 or IEC 60335) — Covers audio/video and appliance safety standards applicable to portable motorized pump devices.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22
Document Page 23
Document Page 24
Document Page 25
Document Page 26
Document Page 27