ETENWOLF S0 Portable Bike Pump Noise Test Report (1 m, Front-Face, 3 Samples)

Document Overview

Key Findings All three ETENWOLF S0 portable bike pump samples were measured at 1 m front-face distance under standard indoor conditions; results are classified For Reference Only against the internal acceptance range of 35–100 dB. Product: ETENWOLF S0 Portable Bike Pump Report No.: 2025080401 Test…

Document type
Test Report
Prepared by
Daniel Wright
Published
Last reviewed
Topics
Noise Testing

Key Findings

All three ETENWOLF S0 portable bike pump samples were measured at 1 m front-face distance under standard indoor conditions; results are classified For Reference Only against the internal acceptance range of 35–100 dB.

  • Product: ETENWOLF S0 Portable Bike Pump
  • Report No.: 2025080401
  • Test Date: 2025-08-04
  • Samples: 3 PCS
  • Test Standard: Internal Standard — Sound Pressure Level Lmax 35–100 dB
  • Measurement Distance: 1 m (microphone horizontal, front-face)
  • Results: 83.2 dB / 81.7 dB / 79.1 dB
  • Verdict: For Reference Only (供参考)

Test Overview

Field Detail
Test Type Noise Testing
Test Category Reliability Test (可靠性测试)
Report No. 2025080401
Test Date 2025-08-04
Product No. / Name ETENWOLF S0 Portable Bike Pump (充气泵)
Model / Type Specification S0
Sample Quantity / No. 3 PCS
Test Standard Internal Standard
Test Purpose Evaluate the noise level of the sample under different operating scenarios
Acceptance Criterion Sound pressure level Lmax 35–100 dB
Test Conditions Room Temperature: 23 °C, Relative Humidity: 60 %

Test Equipment & Setup

Item Detail
Test Equipment Sound Level Meter (噪音计)
Measurement Point Front face of product (正面)
Microphone Distance 1 m (horizontal, aligned with product front face)
Product State During Test Powered on and operating (开机状态)
Ambient Temperature 23 °C
Relative Humidity 60 %

Test Procedure

  1. Pre-test: Confirm ambient conditions — room temperature 23 °C, relative humidity 60 %. Verify sound level meter calibration.
  2. Sample preparation: Label three S0 units as 1#, 2#, and 3#. Place each sample on a stable, flat surface in the test area.
  3. Microphone positioning: Position the sound level meter microphone at a horizontal distance of 1 m from the front face of the product, at the same height as the product’s primary acoustic emission surface.
  4. Measurement: Power on the product. Record the maximum sound pressure level (Lmax) displayed by the noise meter during normal operation.
  5. Repeat: Perform the same measurement procedure for samples 2# and 3#.
  6. Post-test: Power off all samples. Record all measured values and compare against the acceptance criterion of Lmax 35–100 dB.

Acceptance Criterion: Sound pressure level Lmax within 35–100 dB. Results in this report are classified For Reference Only (供参考).

Test Data & Results

Sample No. (编号) Direction (方向) Microphone Distance (距离麦克风距离) Noise Level / dB (噪音)
1# Front (正面) 1 m 83.2
2# Front (正面) 1 m 81.7
3# Front (正面) 1 m 79.1

Observations: All three samples produced sound pressure levels within the internal evaluation range of 35–100 dB. Sample 1# recorded the highest level at 83.2 dB and Sample 3# the lowest at 79.1 dB, giving a spread of 4.1 dB across the batch. No anomalous noise events were noted during testing. Results are designated For Reference Only and do not constitute a pass/fail determination.

Conclusion

Field Detail
Result — Sample 1# 83.2 dB
Result — Sample 2# 81.7 dB
Result — Sample 3# 79.1 dB
Acceptance Standard Internal Standard, Lmax 35–100 dB
Test Conditions 23 °C, 60 % RH; microphone at 1 m front-face
Samples Tested 3 PCS (1#, 2#, 3#)
Verdict For Reference Only (供参考)

Document Information

Role Name (Pinyin) Date
Tested By (测试/日期) Li Guanghua 2025-08-04
Checked By (审核/日期) Zhang Ronggui 2025-08-04
Approved By (核准/日期) Mai Shaoqiang 2025-08-04
Field Detail
Source File S0 充气泵-噪音测试 2025.8.4.xlsx
Sheet Name 噪音测试
Report No. 2025080401

Frequently Asked Questions

How loud is the ETENWOLF S0 portable bike pump during operation?

In controlled testing at 1 m front-face distance, the three S0 samples measured 83.2 dB, 81.7 dB, and 79.1 dB respectively. This places the pump in a typical range for compact electric inflators. The results are classified for reference only under ETENWOLF’s internal evaluation standard.

What test standard was used for the S0 noise test?

ETENWOLF used an internal reliability test standard that evaluates maximum sound pressure level (Lmax) within a range of 35–100 dB. The microphone was positioned at a horizontal distance of 1 m from the front face of the product while it was powered on and operating.

How many samples were tested and what were the individual readings?

Three production samples were tested. Sample 1# recorded 83.2 dB, Sample 2# recorded 81.7 dB, and Sample 3# recorded 79.1 dB, all measured at 1 m from the front face under 23 °C and 60 % relative humidity conditions.

What does ‘For Reference Only’ mean in the ETENWOLF S0 noise report?

‘For Reference Only’ (供参考) means the test results are recorded as informational data and are not subject to a formal pass/fail judgment at this stage. The readings fall within the internal evaluation window of 35–100 dB and serve as a baseline for product development and quality monitoring.