FCC SDoC Test Report WTH25H09260769E – HB3 Air Pump Compliance Verification

Document Overview

Document Overview This article covers the official FCC Supplier’s Declaration of Conformity (SDoC) test report issued for the ETENWOLF HB3 Air Pump. The document is a formal electromagnetic compatibility (EMC) test report prepared by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited third-party testing…

Document type
Certification Report
Prepared by
Michelle Torres
Published
Last reviewed
Topics
North America: FCC / UL

Document Overview

This article covers the official FCC Supplier’s Declaration of Conformity (SDoC) test report issued for the ETENWOLF HB3 Air Pump. The document is a formal electromagnetic compatibility (EMC) test report prepared by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited third-party testing laboratory located in Shenzhen, Guangdong, China.

  • Document Type: FCC Supplier’s Declaration of Conformity (SDoC) – Test Report
  • Reference Number: WTH25H09260769E
  • Test Report Form Number: TRF FCC CFR 47 Part 15 Subpart B-EMC-001-V01
  • Internal Lab Reference: HCT/RF-23-21
  • Issuing Body: Waltek Testing Group HCT (Shenzhen) Co., Ltd.
  • Date of Issue: 2025-10-16
  • Test Period: 2025-09-30 to 2025-10-09
  • Sample Receipt Date: 2025-09-28
  • Scope: Unintentional radiator emissions compliance testing for the United States FCC market under FCC CFR 47 Part 15 Subpart B
  • Overall Test Result: Pass

Product Information

The Equipment Under Test (EUT) evaluated in this report is an electric air pump designed for inflation applications. The product is manufactured and sold under the ETENWOLF brand. Full product details as recorded in the test report are listed below.

Field Details
Product Name AIR PUMP
Model Number (as tested) PUMP5
ETENWOLF Product Model HB3
Applicant Guangdong Bestek Technology Co., LTD
Manufacturer Guangdong Bestek Technology Co., LTD
Manufacturer Address No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China
Product Category Electric inflation tool / air pump
Intended Market United States (FCC jurisdiction)

The HB3 is a portable electric air pump from ETENWOLF’s inflation tools lineup, engineered for inflating tires, sports equipment, and inflatables. As an unintentional radiator, it is subject to FCC Part 15 Subpart B emissions limits.

Key Details

The test report encompasses conducted emission and radiated emission measurements performed on the EUT. The following tables summarize the key procedural and results information extracted from the document.

Test Scope Summary

Test Category Regulation Reference Result
Conducted Emission FCC CFR 47 Part 15 Subpart B Pass
Radiated Emission FCC CFR 47 Part 15 Subpart B Pass

Test Configuration Details

Parameter Information
EUT Exercise Method Software/operational exercise as defined in Section 2.2 of the report
Equipment Modifications None (per Section 2.3)
Test System Configuration Basic configuration per Section 2.4 general test procedures
Decision Rule Applied As defined in Section 2.6 of the test report
Measurement Uncertainty Documented per Section 3.1 (Conducted) and corresponding radiated section

Key Personnel

Role Name
Prepared By Snow Zeng
Approved By Tony Wu

Laboratory Contact

Detail Information
Laboratory Waltek Testing Group HCT (Shenzhen) Co., Ltd.
Address Building B, Tianji Industrial Park, 1/F. & 2/F. & 3/F., No.30-9, Laiyin Road, Xinsheng Community, Longgang Subdistrict, Longgang District, Shenzhen, Guangdong, China
Tel 0755-84616666
Service Tel 400-0066-989
Email [email protected]

Standards & Compliance

The HB3 Air Pump was tested against the following regulatory standards and specifications to achieve FCC SDoC compliance for the US market.

Primary Test Standard

Standard Scope Applicability
FCC CFR 47 Part 15 Subpart B Unintentional Radiators – Conducted and Radiated Emissions limits Mandatory for all unintentional digital/electronic devices sold in the US

Test Report Form Reference

The testing was conducted using standardized test report form TRF FCC CFR 47 Part 15 Subpart B-EMC-001-V01, which defines the measurement procedures, limit lines, instrumentation setup, and pass/fail criteria applicable to unintentional radiators under FCC jurisdiction.

Compliance Pathway

The product follows the Supplier’s Declaration of Conformity (SDoC) pathway, which requires the responsible party (the applicant/manufacturer) to self-declare compliance based on third-party test evidence. The SDoC pathway is applicable to Class B unintentional radiators under FCC Part 15 Subpart B, and does not require FCC registration or a granted authorization number. The test result of Pass across all applicable emission categories supports a valid SDoC declaration.

Validity & Certification Body

Report Validity

Parameter Detail
Report Reference Number WTH25H09260769E
Date of Issue 2025-10-16
Test Period 2025-09-30 to 2025-10-09
Sample Receipt 2025-09-28
Validity Scope Supports FCC SDoC for model PUMP5 / HB3 Air Pump as tested and configured
Validity Condition Valid for the product configuration tested; changes to circuitry, enclosure, or power supply may require re-testing

Testing Laboratory

Waltek Testing Group HCT (Shenzhen) Co., Ltd. is a professional third-party EMC and safety testing laboratory operating under the Waltek Testing Group. The laboratory is located in Longgang District, Shenzhen, Guangdong, China, and provides accredited testing services for global market access certifications including FCC, CE, and other international compliance programs.

Detail Information
Laboratory Name Waltek Testing Group HCT (Shenzhen) Co., Ltd.
Internal Reference HCT/RF-23-21
Website hct-test.com
Prepared By Snow Zeng
Approved By Tony Wu

Frequently Asked Questions

What does FCC SDoC mean for the HB3 Air Pump?

FCC SDoC stands for Supplier’s Declaration of Conformity. It means that the responsible party — in this case Guangdong Bestek Technology Co., LTD — has tested the HB3 Air Pump through an accredited laboratory and confirmed that it meets the electromagnetic emissions limits defined in FCC CFR 47 Part 15 Subpart B. This declaration allows the product to be legally marketed and sold in the United States without additional FCC registration, as long as the product matches the tested configuration.

What test report number covers the HB3 Air Pump FCC compliance?

The FCC SDoC compliance of the HB3 Air Pump is supported by test report reference number WTH25H09260769E, issued on 2025-10-16 by Waltek Testing Group HCT (Shenzhen) Co., Ltd. The internal lab reference for this report is HCT/RF-23-21.

Which emissions tests were performed and what were the results?

The testing covered both conducted emissions and radiated emissions as required by FCC CFR 47 Part 15 Subpart B for unintentional radiators. The HB3 Air Pump passed all applicable test categories. The test was conducted between 2025-09-30 and 2025-10-09 on a sample received on 2025-09-28.

Does the FCC SDoC certification expire or become invalid?

An FCC SDoC does not have a fixed expiration date, but it becomes invalid if the product undergoes changes that could affect its electromagnetic emissions — such as modifications to the PCB, motor, power supply, or enclosure. If such changes occur, the HB3 would need to be re-tested. The current report (WTH25H09260769E) is valid for the exact product configuration tested in September–October 2025.

Related Documents

The following certification and compliance documents are typically associated with a product like the HB3 Air Pump and may be available or applicable depending on target markets:

  • CE EMC Declaration (EU) – Electromagnetic compatibility testing under EU Directive 2014/30/EU, typically referencing IEC CISPR 32/EN 55032 standards for emissions and EN 55035 for immunity.
  • CE LVD (Low Voltage Directive) – Safety testing for electrically powered devices under EU Directive 2014/35/EU, referencing IEC 62368-1 or IEC 60335 series.
  • RoHS Compliance Declaration – Confirms restriction of hazardous substances per EU RoHS Directive 2011/65/EU, covering lead, mercury, cadmium, and other restricted materials.
  • REACH SVHC Declaration – Substance of Very High Concern declaration under EU REACH Regulation (EC) No 1907/2006.
  • KC Certification (South Korea) – Electromagnetic compatibility and safety certification required for products sold in South Korea, managed by the National Radio Research Agency (RRA).
  • California Proposition 65 Warning – If applicable, documentation confirming compliance or required warnings for sale in California, USA.
  • IEC 62368-1 Safety Report – Audio/video, information and communication technology equipment safety standard applicable to powered accessories and inflation tools.

Document Pages

Document Page 1
Document Page 2
Document Page 3
Document Page 4
Document Page 5
Document Page 6
Document Page 7
Document Page 8
Document Page 9
Document Page 10
Document Page 11
Document Page 12
Document Page 13
Document Page 14
Document Page 15
Document Page 16
Document Page 17
Document Page 18
Document Page 19
Document Page 20
Document Page 21
Document Page 22
Document Page 23
Document Page 24
Document Page 25