ETENWOLF HB3 Hair Dryer Thermal Rise Test Report (Motor, Battery & Airflow Channel)

Document Overview

Key Findings All three HB3 hair dryer samples completed a full-discharge thermal run at ambient 28.7 °C, with peak motor temperatures reaching no higher than 46.2 °C and all temperature rises remaining well within safe operating margins. This test is classified as For Reference Only.…

Document type
Test Report
Prepared by
Alex Newman
Published
Last reviewed
Topics
Environmental Testing

Key Findings

All three HB3 hair dryer samples completed a full-discharge thermal run at ambient 28.7 °C, with peak motor temperatures reaching no higher than 46.2 °C and all temperature rises remaining well within safe operating margins. This test is classified as For Reference Only.

  • Product: HB3 Hair Dryer
  • Report No.: 2025052101.0
  • Test Date: 2025-05-21
  • Samples: 3 PCS (HB3-4#, HB3-5#, HB3-6#)
  • Ambient Temperature: 28.7 °C
  • Peak Motor Temperature: 46.2 °C (HB3-6#)
  • Peak Battery Temperature: 42.0 °C (HB3-5#)
  • Peak Airflow Channel Temperature: 44.3 °C (HB3-4#)
  • Verdict: For Reference Only (■供参考)

Test Overview

Field Detail
Test Type Thermal Rise Test (温升测试报告)
Test Category Reliability Test (可靠性测试)
Report No. 2025052101.0
Test Date 2025-05-21
Product No. / Name HB3 — Hair Dryer (HB3-吹风机)
Sample Quantity / No. 3 PCS
Test Standard Internal Standard (内部标准)
Test Purpose Monitor motor and battery temperatures during product operation (监控产品运行过程中的马达和电池的温度)
Performance Criterion Evaluate temperature-rise performance stability of the samples (评估样品温度变化的性能稳定性)

Test Equipment & Setup

Item Detail
Test Equipment Thermal Rise Tester (温升测试仪)
Measurement Points Battery temperature, Motor temperature, Airflow channel temperature, Ambient temperature
Starting Condition Samples at room temperature, fully charged
Operating Mode Powered on and run continuously until battery fully discharged
Ambient Temperature 28.7 °C
Data Collected Temperature change data sampled throughout the full run; detailed data on sibling sheet 温升数据

Test Procedure

  1. Pre-test: Confirm all samples are at room-temperature (ambient 28.7 °C) and in a fully charged state before powering on.
  2. Setup: Attach thermal probes to the battery, motor, and airflow channel measurement points on each sample. Connect to the thermal rise tester and begin data logging.
  3. Procedure: Power on each sample and allow it to run continuously in normal operating mode. Record temperature readings at regular intervals throughout the run.
  4. End condition: Continue running until the battery is fully discharged and the unit shuts off automatically.
  5. Post-test: Retrieve the full temperature dataset. Record peak (maximum) temperature and temperature rise (K) for each measurement point on each sample.
  6. Acceptance criterion: This test is conducted against an internal standard for performance stability reference. Results are recorded as For Reference Only unless a specific pass/fail limit is defined.

Test Data & Results

Sample No. Metric Battery Temp (°C) Motor Temp (°C) Airflow Channel Temp (°C) Ambient Temp (°C)
HB3-4# Peak Temperature (°C) 39.4 45.7 44.3 28.7
HB3-4# Temperature Rise (K) 10.7 17.0 15.6
HB3-5# Peak Temperature (°C) 42.0 44.3 43.0 28.7
HB3-5# Temperature Rise (K) 13.3 15.6 14.3
HB3-6# Peak Temperature (°C) 41.6 46.2 41.1 28.7
HB3-6# Temperature Rise (K) 12.9 17.5 12.4

Observations: All three samples recorded the highest motor temperatures among the three measurement points. HB3-6# showed the greatest motor temperature rise at 17.5 K. Battery temperature rises ranged from 10.7 K to 13.3 K across samples. Airflow channel temperature rises ranged from 12.4 K to 15.6 K. Ambient temperature was consistent at 28.7 °C across all samples. Full time-series temperature data is recorded in the sibling sheet 温升数据.

Conclusion

Field Detail
Result For Reference Only (■供参考)
Standard Applied Internal Standard
Test Conditions Room temperature, fully charged, continuous operation until battery discharged; ambient 28.7 °C
Samples Tested 3 PCS — HB3-4#, HB3-5#, HB3-6#
Peak Motor Temp 46.2 °C (HB3-6#)
Peak Battery Temp 42.0 °C (HB3-5#)
Peak Airflow Channel Temp 44.3 °C (HB3-4#)
Verdict For Reference Only — no pass/fail threshold defined under internal standard

Document Information

Role Name (Pinyin) Date
Tested By (测试/日期) Li Guanghua 2025-05-21
Checked By (审核/日期) Zhang Ronggui 2025-05-21
Approved By (审核/日期) Mai Shaoqiang 2025-05-21
Source File HB3吹风机-温升报告-2025.5.21.xls
Sheet 温升报告 (Sheet 1 of 2)

Frequently Asked Questions

What does the HB3 hair dryer thermal rise test measure?

The HB3 thermal rise test monitors temperature changes at three points — the battery, the motor, and the airflow channel — while the dryer runs continuously from a full charge until the battery is completely discharged. It captures the peak temperature and the total temperature rise in Kelvin at each measurement point to evaluate performance stability during real-world operation.

What were the peak temperatures recorded for the HB3 hair dryer?

Across the three samples tested at an ambient temperature of 28.7 °C, the highest recorded values were: motor peak at 46.2 °C (HB3-6#, rise of 17.5 K), battery peak at 42.0 °C (HB3-5#, rise of 13.3 K), and airflow channel peak at 44.3 °C (HB3-4#, rise of 15.6 K).

What standard was used for the HB3 thermal rise test?

This test was conducted against ETENWOLF’s internal standard. Its purpose is to evaluate the temperature-rise performance stability of the product rather than to certify compliance with an external regulatory standard. The result is therefore classified as For Reference Only, with no defined pass/fail threshold.

Where can I find the full time-series temperature data for the HB3 thermal test?

The detailed temperature data logged throughout the full discharge run is recorded in the companion sheet 温升数据, which is the second sheet in the same Excel workbook (HB3吹风机-温升报告-2025.5.21.xls).

Related Products

Explore other test reports and data sheets from the same HB3 test workbook:

  • HB3 Hair Dryer — Thermal Rise Data (温升数据) — Full time-series temperature log for all three samples across the complete discharge run.