Document Overview
Key Findings The ETENWOLF X5PRO tire inflator completed a 1-hour random-axis transport vibration test per ISTA-2A with no functional failure and no appearance abnormality. Test Standard: ISTA-2A Test Duration: 1 hour Vibration Mode: Random (X, Y, Z axes) Vibration Frequency: 4 Hz Test Speed (CMP):…
- Document type
- Test Report
- Prepared by
- Daniel Wright
- Published
- Last reviewed
- Topics
- Mechanical Reliability
Key Findings
The ETENWOLF X5PRO tire inflator completed a 1-hour random-axis transport vibration test per ISTA-2A with no functional failure and no appearance abnormality.
- Test Standard: ISTA-2A
- Test Duration: 1 hour
- Vibration Mode: Random (X, Y, Z axes)
- Vibration Frequency: 4 Hz
- Test Speed (CMP): 240 G
- Vibration Amplitude: 25.4 mm
- Sample Quantity: 2 PCS
- Verdict: Pass — power-on function intact, no failure detected
Test Overview
| Field | Detail |
|---|---|
| Report Title | Vibration Test Report |
| Report No. | 2025091801 |
| Page | 1 |
| Date | 2025-09-18 |
| Product Name | X5PRO Tire Inflator (X5-充气泵) |
| Manufacturer | BTK |
| Surface Treatment | / |
| Sample Quantity | 2 PCS |
| Test Class / Standard | ISTA-2A |
| Test Reason | New Product |
| Test Objective | To verify the resistance of the sample in transportation and use environment. |
| Laboratory Temperature | 22 °C |
| Laboratory Humidity | 55% RH |
Test Equipment & Setup
| Parameter | Value |
|---|---|
| Instrument Name | Vibration Testing Machine |
| Test Pattern | Random Mode |
| Test Duration | 1 H |
| Random Direction | X, Y, Z |
| Vibration Frequency | 4 Hz |
| Test Speed (CMP) | 240 G |
| Vibration Amplitude | 25.4 mm |
| Test Requirement | Power-on function must show no failure after test |
Test Procedure
- Pre-test inspection: Visually inspect both sample units for pre-existing defects; record appearance and confirm power-on function is normal.
- Sample placement: Mount samples on the vibration testing machine platform in the designated orientation (vibration placement as shown in test picture).
- Vibration test execution: Run random vibration mode simultaneously across X, Y, and Z axes for 1 hour at 4 Hz frequency, 240 G CMP speed, and 25.4 mm amplitude in accordance with ISTA-2A.
- Post-test inspection — appearance: Inspect both units for cracks, deformation, loose parts, or any cosmetic abnormality.
- Post-test inspection — function: Power on each unit and verify all functions operate normally; confirm charging function is normal.
- Acceptance criteria: All samples must power on without failure and show no appearance abnormality to receive a Pass judgment.
Test Data & Results
| Inspection Item | Sample 1 | Sample 2 |
|---|---|---|
| Pre-test appearance | Normal | Normal |
| Pre-test power-on function | Normal | Normal |
| Vibration placement / control chart | Normal | Normal |
| Post-transport appearance | No abnormality | No abnormality |
| Post-test charging function | Normal | Normal |
| Post-test power-on function | No failure | No failure |
Test Result Statement: Both samples completed the 1-hour transport vibration test with stable performance and no functional failure.
Conclusion
| Field | Detail |
|---|---|
| Result | Pass |
| Standard Applied | ISTA-2A |
| Test Conditions | Random vibration, X/Y/Z axes, 1 H, 4 Hz, 240 G, 25.4 mm amplitude, 22 °C / 55% RH |
| Samples Tested | 2 PCS |
| Verdict | ■ Pass □ Fail □ Reference |
Document Information
| Role | Name (Pinyin) |
|---|---|
| Approval (核准) | Mai Shaoqiang |
| Review (审查) | Zhang Ronggui |
| Tester (试验人) | Li Guanghua |
| Form Number (表单编号) | BTK-R-Q-087A/1 |
Frequently Asked Questions
What does the ISTA-2A vibration test evaluate for the ETENWOLF X5PRO?
The ISTA-2A vibration test simulates the mechanical stresses a packaged product encounters during real-world transportation. For the X5PRO tire inflator, it verifies that the unit survives random vibration across all three axes (X, Y, Z) for one hour at 4 Hz and 240 G without functional failure or physical damage.
What were the specific vibration parameters used in the X5PRO test?
The test used random mode, running simultaneously on the X, Y, and Z axes for 1 hour. Key parameters were: vibration frequency 4 Hz, test speed 240 G (CMP), and vibration amplitude 25.4 mm. The lab environment was maintained at 22 °C and 55% RH throughout.
Did the ETENWOLF X5PRO pass the transport vibration test?
Yes. Both samples passed. After completing the 1-hour ISTA-2A random vibration test, the X5PRO showed no appearance abnormality and all power-on and charging functions remained fully operational.
How many X5PRO units were tested and who conducted the test?
Two production samples (2 PCS) were tested. The test was conducted by Li Guanghua, reviewed by Zhang Ronggui, and approved by Mai Shaoqiang at manufacturer BTK on 2025-09-18 under report number 2025091801.
Related Products
- ETENWOLF Inflation Tools — Full Product Range
- Report Series: X5PRO Transport Vibration Test Report — Sheet: 测试报告 (Report No. 2025091801)