Document Overview
Document Overview This article covers the official CE Electromagnetic Compatibility (EMC) test report issued for the ETENWOLF S1 portable tire inflator. The report was prepared and issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited third-party electromagnetic compatibility testing laboratory located in Longgang…
- Document type
- Certification Report
- Prepared by
- Michelle Torres
- Published
- Last reviewed
- Topics
- European Union: CE / RoHS / REACH / WEEE
Document Overview
This article covers the official CE Electromagnetic Compatibility (EMC) test report issued for the ETENWOLF S1 portable tire inflator. The report was prepared and issued by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited third-party electromagnetic compatibility testing laboratory located in Longgang District, Shenzhen, Guangdong, China.
| Field | Detail |
|---|---|
| Reference Number | WTH25H12333145E |
| Test Report Form Number | TRF EN IEC 55014-1: 2021-EMC-001-V01 |
| Internal Form Reference | HCT/RF-23-21 |
| Document Type | CE-EMC Test Report |
| Issuing Laboratory | Waltek Testing Group HCT (Shenzhen) Co., Ltd. |
| Date Sample Received | 2025-12-12 |
| Date of Testing | 2025-12-15 to 2025-12-19 |
| Date of Issue | 2025-12-25 |
| Overall Test Result | Pass |
The scope of this report covers conducted disturbance at mains terminals, disturbance power in the frequency range, and radiated disturbances, fully addressing the electromagnetic emissions requirements mandated under the CE marking directive for this product category.
Product Information
The Equipment Under Test (EUT) evaluated in this report is the ETENWOLF S1 portable tire inflator, a compact inflation tool designed for automotive and consumer use. The product is manufactured and distributed by Guangdong Bestek Technology Co., Ltd., the applicant of record for this certification.
| Field | Detail |
|---|---|
| Product Name | Tire Pump |
| Model Number | S1 |
| Brand | ETENWOLF |
| Applicant | Guangdong Bestek Technology Co., LTD |
| Applicant Address | No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China |
| Manufacturer | Guangdong Bestek Technology Co., LTD |
| Manufacturer Address | No.1, North Gaopu 8th Road, Yuancheng Industrial Park, Heyuan City, Guangdong, P.R. China |
The ETENWOLF S1 is a portable, motorized tire inflator intended for inflating vehicle tires and other inflatable items. As a motor-driven electrical appliance, it falls within the scope of the CISPR 14 / EN IEC 55014 standard series governing electromagnetic emissions from household and similar electrical apparatus.
Key Details
The test report covers multiple EMC measurement disciplines, each corresponding to a defined section of the applicable standards. The following table summarizes the test areas, the relevant standard clauses, and the results recorded during the evaluation of the ETENWOLF S1.
| Test Section | Test Description | Applicable Standard | Result |
|---|---|---|---|
| Section 3 | Conducted Disturbance at Mains Terminals | EN IEC 55014-1: 2021 | Pass |
| Section 4 | Disturbance Power in the Frequency Range | EN IEC 55014-1: 2021 | Pass |
| Section 5 | Radiated Disturbances | EN IEC 55014-1: 2021 | Pass |
| Immunity | Electromagnetic Immunity (EMS) | EN IEC 55014-2: 2021 | Pass |
| Harmonics | Harmonic Current Emissions | EN IEC 61000-3-2: 2019+A1:2021 | Pass |
| Flicker | Voltage Fluctuations and Flicker | EN 61000-3-3: 2013+A2:2021 | Pass |
The test methodology followed the procedures defined in TRF EN IEC 55014-1: 2021-EMC-001-V01. Measurement uncertainty was documented for each test section in accordance with laboratory accreditation requirements. Equipment modifications were assessed and justified prior to testing. The EUT was exercised under representative operating conditions throughout all measurements.
| Report Personnel | Role |
|---|---|
| Snow Zeng | Prepared By |
| Tony Wu | Approved By |
Standards & Compliance
The ETENWOLF S1 was tested against the following harmonized European standards, which support conformity with the CE marking Electromagnetic Compatibility (EMC) Directive 2014/30/EU. All standards listed are the versions specified in the original test report.
| Standard | Title | Scope |
|---|---|---|
| EN IEC 55014-1: 2021 | Electromagnetic Compatibility – Requirements for Household Appliances, Electric Tools and Similar Apparatus – Part 1: Emission | Conducted and radiated emissions from motor-operated and thermostatically controlled appliances |
| EN IEC 55014-2: 2021 | Electromagnetic Compatibility – Requirements for Household Appliances, Electric Tools and Similar Apparatus – Part 2: Immunity | Immunity requirements for the same equipment category |
| EN IEC 61000-3-2: 2019+A1:2021 | Electromagnetic Compatibility – Limits for Harmonic Current Emissions | Limits for harmonic current emissions for equipment with input current up to and including 16 A per phase |
| EN 61000-3-3: 2013+A2:2021 | Electromagnetic Compatibility – Limitation of Voltage Changes, Voltage Fluctuations and Flicker | Limits for voltage changes and flicker for equipment with rated current up to and including 16 A per phase |
These standards are published by the International Electrotechnical Commission (IEC) and adopted as harmonized European Norms (EN) by CENELEC. Conformance to these standards provides a presumption of conformity with the essential requirements of the CE EMC Directive, enabling the CE mark to be affixed to the product for distribution in the European Economic Area.
Validity & Certification Body
The test report WTH25H12333145E was issued on 2025-12-25 by Waltek Testing Group HCT (Shenzhen) Co., Ltd. This laboratory is responsible for the accuracy and integrity of all measurements and conclusions contained within the report. The report is valid as evidence of EMC compliance for the specific model and configuration tested.
| Field | Detail |
|---|---|
| Issuing Laboratory | Waltek Testing Group HCT (Shenzhen) Co., Ltd. |
| Laboratory Address | Building B, Tianji Industrial Park, 1/F. & 2/F. & 3/F., No.30-9, Laiyin Road, Xinsheng Community, Longgang Subdistrict, Longgang District, Shenzhen, Guangdong, China |
| Telephone | 0755-84616666 |
| Service Hotline | 400-0066-989 |
| [email protected] | |
| Website | http://www.hct-test.com |
| Report Issue Date | 2025-12-25 |
| Report Reference Number | WTH25H12333145E |
| Internal Form Reference | HCT/RF-23-21 |
The report covers the product in the exact configuration submitted for testing. Any hardware, firmware, or design changes to the ETENWOLF S1 after the test date may require re-evaluation to maintain the validity of this CE-EMC certification. The CE mark may only be applied to units manufactured to the same specification as the tested sample.
Frequently Asked Questions
- What does CE-EMC certification mean for the ETENWOLF S1?
-
CE-EMC certification confirms that the ETENWOLF S1 portable tire inflator meets the electromagnetic compatibility requirements of the European EMC Directive 2014/30/EU. This means the product does not generate electromagnetic interference beyond permitted limits and is sufficiently immune to external electromagnetic disturbances. It is a mandatory requirement for legally placing the product on the market within the European Economic Area.
- Which specific standards were used to test the ETENWOLF S1 for CE-EMC compliance?
-
The ETENWOLF S1 was tested against four harmonized European standards: EN IEC 55014-1: 2021 (emissions), EN IEC 55014-2: 2021 (immunity), EN IEC 61000-3-2: 2019+A1:2021 (harmonic current emissions), and EN 61000-3-3: 2013+A2:2021 (voltage fluctuations and flicker). All tests resulted in a Pass.
- Who conducted the CE-EMC testing for the ETENWOLF S1?
-
Testing was conducted by Waltek Testing Group HCT (Shenzhen) Co., Ltd., an accredited EMC testing laboratory based in Shenzhen, Guangdong, China. The report was prepared by Snow Zeng and approved by Tony Wu. Testing took place from 2025-12-15 to 2025-12-19, with the report issued on 2025-12-25.
- Does a change in product design invalidate report WTH25H12333145E?
-
Yes. Report WTH25H12333145E is valid only for the ETENWOLF S1 in the exact hardware and firmware configuration that was submitted and tested. Any significant design change — including modifications to the motor, power circuitry, enclosure, or firmware — may require a supplementary or full re-test to maintain CE-EMC compliance.
Related Documents
The CE-EMC test report WTH25H12333145E is one component of the complete compliance documentation package for the ETENWOLF S1 portable tire inflator. The following related certification and test document types are typically required or recommended for a product of this category:
- CE-LVD (Low Voltage Directive) Test Report — Covers electrical safety testing to EN IEC 62368-1 or EN 60335 series, required for products powered by mains or rechargeable battery packs above defined voltage thresholds.
- CE Declaration of Conformity (DoC) — The manufacturer’s formal declaration combining all applicable directives (EMC, LVD, RoHS) into a single compliance statement required to affix the CE mark.
- UN 38.3 Battery Transport Test Report — Required for products containing lithium-ion or lithium-polymer battery cells for safe transport classification under IATA and IMDG regulations.
- RoHS Compliance Report / Test Report — Confirms restriction of hazardous substances (lead, mercury, cadmium, hexavalent chromium, PBB, PBDE) in accordance with EU RoHS Directive 2011/65/EU.
- REACH SVHC Declaration — Addresses substances of very high concern under EU REACH Regulation (EC) No 1907/2006, required for products sold in the European market.
- FCC ID Authorization / SDOC — Required for sale in the United States market; covers unintentional radiator emissions under FCC Part 15 rules.
- KC Certification (Korea) — Required for electrical and electronic products sold in the Republic of Korea market under the KC safety scheme.
Document Pages