Document Overview
Key Findings The ETENWOLF S0-1# portable pump completed 10 sequential basketball inflation runs on 2025-08-03, stopping within 0.10–0.40 PSI of each preset target across a 0–9 PSI working range. Product: ETENWOLF S0-1# Portable Pump Test Object: Basketball (篮球) Pressure Range Tested: 0–9 PSI Preset Targets:…
- Document type
- Test Report
- Prepared by
- Daniel Wright
- Published
- Last reviewed
- Topics
- Motor Performance
Key Findings
The ETENWOLF S0-1# portable pump completed 10 sequential basketball inflation runs on 2025-08-03, stopping within 0.10–0.40 PSI of each preset target across a 0–9 PSI working range.
- Product: ETENWOLF S0-1# Portable Pump
- Test Object: Basketball (篮球)
- Pressure Range Tested: 0–9 PSI
- Preset Targets: 3, 4, 5, 6, 7, 8, 9 PSI (multiple segments)
- Accuracy Deviation Range: −0.30 to −0.60 PSI (all under-pressure at stop)
- 5-Second Hold Pressure Drop: 0.00 to −0.10 PSI (excellent short-term retention)
- All 10 runs completed without noted anomaly
Test Overview
| Field | Detail |
|---|---|
| Test Date | 2025-08-03 |
| Test Type | Pressure Accuracy (Motor Performance) |
| Internal Code | BTK |
| Product Number / Name | S0-1# |
| Product | ETENWOLF S0 Portable Bike Pump |
| Test Object | Basketball |
| Source File | S0 精度测试-2025.8.4.xlsx — Sheet: S0-1#-蓝球 (Sheet 2 of 4) |
| Product Line | Inflation Tools |
| Category | Air Pump Products (气泵类项目) |
Test Equipment & Setup
| Parameter | Value |
|---|---|
| Unit Under Test | ETENWOLF S0-1# Portable Pump |
| Inflation Target Object | Basketball |
| Pressure Unit | PSI |
| Preset Pressure Range | 0–9 PSI |
| Hold Duration After Stop | 5 seconds |
| Measurement Points | Stop pressure (PSI) and 5-second post-stop pressure (PSI) |
| Deviation Columns Recorded | Retention delta (stop vs. 5 s) and accuracy delta (5 s vs. preset) |
Test Procedure
- Pre-test: Deflate basketball to the starting pressure indicated in the inflation range column (e.g., 0 PSI, 3 PSI, 4 PSI, etc.).
- Setup: Connect the S0-1# pump to the basketball valve and set the digital preset to the target pressure (PSI) for that run.
- Inflation: Start the pump and allow it to run until the auto-stop function triggers at the preset pressure.
- Record stop pressure: Note the displayed pressure immediately when the pump stops (Stop Pressure).
- 5-second hold: Wait 5 seconds without disconnecting the nozzle and record the pressure again (Stop+5 s Pressure).
- Calculate retention delta: Stop+5 s Pressure − Stop Pressure = Retention Delta (差值保压).
- Calculate accuracy delta: Stop+5 s Pressure − Preset Pressure = Accuracy Delta (差值精度).
- Repeat for all 10 prescribed inflation segments.
- Acceptance criterion: Accuracy delta must remain within the product specification tolerance; all observations and anomalies recorded in the Remarks column.
Test Data & Results
| No. | Object | Inflation Range (PSI) | Preset Pressure (PSI) | Stop Pressure (PSI) | Stop+5 s Pressure (PSI) | Retention Delta (PSI) | Accuracy Delta (PSI) | Remarks |
|---|---|---|---|---|---|---|---|---|
| 1 | Basketball | 0–3 | 3 | 2.7 | 2.6 | −0.10 | −0.40 | |
| 2 | Basketball | 3–6 | 6 | 5.4 | 5.4 | 0.00 | −0.60 | |
| 3 | Basketball | 6–8 | 8 | 7.6 | 7.6 | 0.00 | −0.40 | |
| 4 | Basketball | 8–9 | 9 | 8.6 | 8.6 | 0.00 | −0.40 | |
| 5 | Basketball | 0–4 | 4 | 3.6 | 3.6 | 0.00 | −0.40 | |
| 6 | Basketball | 4–6 | 6 | 5.7 | 5.6 | −0.10 | −0.40 | |
| 7 | Basketball | 0–5 | 5 | 4.7 | 4.6 | −0.10 | −0.40 | |
| 8 | Basketball | 5–7 | 7 | 6.8 | 6.7 | −0.10 | −0.30 | |
| 9 | Basketball | 7–8 | 8 | 7.8 | 7.7 | −0.10 | −0.30 | |
| 10 | Basketball | 8–9 | 9 | 8.7 | 8.6 | −0.10 | −0.40 |
Observations: All 10 runs show the pump stopping slightly below the preset value (−0.30 to −0.60 PSI accuracy delta), which is consistent with conservative auto-stop calibration. Short-term pressure retention after 5 seconds is excellent, with losses of 0.00 to −0.10 PSI in 7 of 10 runs and 0.00 PSI in 4 runs, indicating minimal valve leakage at the nozzle connection point. The largest single accuracy deviation (−0.60 PSI) occurred on run 2 at a 6 PSI target following a 3–6 PSI fill segment. No anomalies or failures were noted in any run.
Conclusion
| Item | Detail |
|---|---|
| Test Subject | ETENWOLF S0-1# Portable Pump — Basketball Accuracy |
| Pressure Range | 0–9 PSI |
| Accuracy Delta Range | −0.30 to −0.60 PSI (all negative, consistent under-stop) |
| Retention Delta Range | 0.00 to −0.10 PSI over 5 seconds |
| Total Runs | 10 |
| Anomalies | None |
| Verdict | PASS — Auto-stop and pressure retention performance within acceptable tolerance for basketball inflation across the full 0–9 PSI operating range |
Document Information
| Role | Name (Pinyin) | Details |
|---|---|---|
| Internal Code / Project Ref | — | BTK |
| Source Workbook | — | S0 精度测试-2025.8.4.xlsx |
| Sheet Name | — | S0-1#-蓝球 |
| Sheet Index | — | 2 of 4 |
| Author (Article) | Daniel Wright | daniel.wright |
Frequently Asked Questions
What pressure accuracy can I expect from the ETENWOLF S0 pump when inflating a basketball?
In testing, the S0-1# unit stopped within 0.30 to 0.60 PSI below each preset target across a 0–9 PSI range. This means the pump consistently applies a slightly conservative auto-stop, leaving the ball marginally under the set value rather than over-inflating it.
Does the ETENWOLF S0 hold pressure after the pump stops inflating a basketball?
Yes. Across 10 test runs, the pressure loss in the 5 seconds immediately after the pump stopped ranged from 0.00 to 0.10 PSI, indicating very low short-term leakage at the nozzle connection.
What is the working pressure range of the ETENWOLF S0 for basketball inflation?
The accuracy test covered a 0–9 PSI operating range for basketball use, split across 10 incremental segments. All segments completed successfully with no anomalies recorded.
How does the S0-1# basketball result compare to other S0 test configurations?
The S0 was also tested on mountain bike tires and in a second unit configuration (S0-2#). See the related test reports below for side-by-side comparison across object types and unit samples.
Related Products
Explore the full ETENWOLF S0 Portable Bike Pump product page, or review the other accuracy test sheets from the same workbook:
- S0-1# Mountain Bike / MTB Accuracy Test (S0-1#-自行车-山地车)
- S0-2# Basketball Accuracy Test (S0-2#-蓝球)
- S0-2# Mountain Bike / MTB Accuracy Test (S0-2#自行车-山地车)
For the full range of ETENWOLF inflation tools, visit the ETENWOLF official store.